{"product_id":"ds200pccag6acb-ge-mark-v-power-connect-card","title":"DS200PCCAG6ACB GE Mark V Power Connect Card","description":"\u003ch2\u003e\u003cstrong\u003eDS200PCCAG6ACB Power Connect Card for GE Mark V Series\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e General Electric (GE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eDS200PCCAG6ACB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Power Connect Card\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Acronym:\u003c\/strong\u003e PCCA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstruction Manual:\u003c\/strong\u003e GEI-100161\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Coating:\u003c\/strong\u003e Normal Coating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Revisions:\u003c\/strong\u003e A and C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArtwork Revision:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoard Group:\u003c\/strong\u003e Group 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 240 through 700 volts, depending on group type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Conversion:\u003c\/strong\u003e Regenerative and non-regenerative options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectors:\u003c\/strong\u003e Twelve plug connectors for SCR bridge signals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-Board Memory:\u003c\/strong\u003e RAM included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Manufacture:\u003c\/strong\u003e United States (USA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe board acts as an interface between the drive and the silicon-controlled rectifier power bridge.\u003c\/li\u003e\n\u003cli\u003eIt transmits control signals, commands, and feedback between critical drive components.\u003c\/li\u003e\n\u003cli\u003eIt supports real-time monitoring of current, voltage, and temperature readings.\u003c\/li\u003e\n\u003cli\u003eIt helps regulate power output and voltage levels for stable drive operation.\u003c\/li\u003e\n\u003cli\u003eIt integrates with the drive control circuitry through a standardized interface.\u003c\/li\u003e\n\u003cli\u003eIt minimizes signal loss and interference under various operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGroup and Voltage Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGroups 1, 7, and 9 use regenerative power conversion from 240 through 630 volts.\u003c\/li\u003e\n\u003cli\u003eGroups 2, 8, and 10 use non-regenerative power conversion from 240 through 700 volts.\u003c\/li\u003e\n\u003cli\u003eGroups 1 and 2, 3 and 4, 5 and 6, 7 and 8, and 9 and 10 share the same application specifications.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eDS200PCCAG6ACB\u003c\/strong\u003e belongs to group 6.\u003c\/li\u003e\n\u003cli\u003eGroup selection depends on voltage, frame size, and power conversion type.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSnubber Circuits and Horsepower Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-to-medium horsepower controllers include snubber circuits on the board.\u003c\/li\u003e\n\u003cli\u003eThese circuits suppress transient voltage spikes across AC lines, DC bus, and gate drivers.\u003c\/li\u003e\n\u003cli\u003eThey protect semiconductor devices and control circuitry from potential damage.\u003c\/li\u003e\n\u003cli\u003eHigher horsepower controllers may omit some or all snubber circuits from the PCCA board.\u003c\/li\u003e\n\u003cli\u003eSystem designers may relocate those circuits elsewhere in the drive architecture.\u003c\/li\u003e\n\u003cli\u003eThis modular approach optimizes layout, space, and system performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConfigurable Jumpers\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eJP1 and JP2 are wire jumpers that connect to stab terminals P3 through P10.\u003c\/li\u003e\n\u003cli\u003eCard group number and system voltage determine the correct terminal connections.\u003c\/li\u003e\n\u003cli\u003eThese connections are critical for proper voltage regulation and control.\u003c\/li\u003e\n\u003cli\u003eWP3 and WP4 connect stab terminals P2A to P2B and P1A to P1B.\u003c\/li\u003e\n\u003cli\u003eThese jumpers select whether snubber capacitors share the same power bridge point as the voltage feedback channel.\u003c\/li\u003e\n\u003cli\u003eCorrect jumper placement ensures effective suppression of voltage spikes and transient disturbances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the card group number and system voltage before installation.\u003c\/li\u003e\n\u003cli\u003eSet JP1 and JP2 jumpers according to the required stab terminals P3 through P10.\u003c\/li\u003e\n\u003cli\u003eConfigure WP3 and WP4 jumpers based on the snubber capacitor and voltage feedback requirement.\u003c\/li\u003e\n\u003cli\u003eConnect the twelve plug connectors to the SCR bridge for proper signal transmission.\u003c\/li\u003e\n\u003cli\u003eUse the control panel or a laptop to set parameters in the configuration file.\u003c\/li\u003e\n\u003cli\u003eOperators can download the same file to multiple drives or edit a unique configuration for each drive.\u003c\/li\u003e\n\u003cli\u003eConfirm all connections before applying power to the drive system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003eDS200PCCAG6ACB\u003c\/strong\u003e Power Connect Card\u003c\/li\u003e\n\u003cli\u003e1 x Anti-static protective packaging\u003c\/li\u003e\n\u003cli\u003e1 x Product label and identification tag\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Availability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe keep this product in stock for immediate order processing.\u003c\/li\u003e\n\u003cli\u003eWe ship orders within 5 days after payment confirmation.\u003c\/li\u003e\n\u003cli\u003eWe use FedEx, UPS, and DHL for international delivery.\u003c\/li\u003e\n\u003cli\u003eWe support 30-day returns for eligible orders.\u003c\/li\u003e\n\u003cli\u003eAll items are brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the \u003cstrong\u003eDS200PCCAG6ACB\u003c\/strong\u003e used for?\u003c\/strong\u003e\u003cbr\u003eA: It connects the drive control circuitry to the SCR power bridge in GE Mark V systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which board group does this card belong to?\u003c\/strong\u003e\u003cbr\u003eA: This card belongs to group 6.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What voltage range does this board support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 240 through 700 volts, depending on the group and conversion type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this card include snubber circuits?\u003c\/strong\u003e\u003cbr\u003eA: Low-to-medium horsepower controllers include them, while higher horsepower designs may relocate or omit them.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I configure JP1 and JP2?\u003c\/strong\u003e\u003cbr\u003eA: Connect them to stab terminals P3 through P10 based on card group and system voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What do WP3 and WP4 jumpers control?\u003c\/strong\u003e\u003cbr\u003eA: They select whether snubber capacitors connect to the same power bridge point as the voltage feedback channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this product new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply brand new original products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days using FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you accept returns?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we support 30-day returns.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhone\/WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47899420623009,"sku":"DS200PCCAG6ACB","price":203.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/DS200PCCAG6ACB.jpg?v=1789976668","url":"https:\/\/www.autonexcontrol.com\/products\/ds200pccag6acb-ge-mark-v-power-connect-card","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}