{"product_id":"ds200lppag1aaa-ge-mark-v-line-protection-panel-board","title":"DS200LPPAG1AAA GE Mark V Line Protection Panel Board","description":"\u003ch2\u003e\u003cstrong\u003eDS200LPPAG1AAA Line Protection Panel Board – GE Mark V Series\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e General Electric (GE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eDS200LPPAG1AAA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Line Protection Panel Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e General Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstruction Manual:\u003c\/strong\u003e GEI-100178\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Acronym:\u003c\/strong\u003e LPPA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Input Voltage:\u003c\/strong\u003e 200–600 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup Revision:\u003c\/strong\u003e G1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 230–600 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Input Channels:\u003c\/strong\u003e 12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 125 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Voltage:\u003c\/strong\u003e 28 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e Chassis Mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnology:\u003c\/strong\u003e Surface Mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 33.0 cm × 17.8 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Components and Protection Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Breakers:\u003c\/strong\u003e These devices trip automatically when ground faults, short circuits, or overcurrent conditions occur.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Protection Devices (SPDs):\u003c\/strong\u003e They divert excess voltage from switching events or lightning strikes to ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e Circuit breakers and fuses stop excessive current flow to prevent fire hazards and overheating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Fault Protection:\u003c\/strong\u003e GFPRs and GFCIs detect leakage currents and interrupt the circuit to prevent electric shock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring and Control Systems:\u003c\/strong\u003e These systems provide real-time status data and remote monitoring capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation and Disconnect Switches:\u003c\/strong\u003e Operators use these switches to isolate system sections for safe troubleshooting and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicators and Alarms:\u003c\/strong\u003e These alerts notify operators of faults or abnormal conditions in the electrical system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Layout and Jumper Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe board includes \u003cstrong\u003eseven jumpers (JP1–JP7)\u003c\/strong\u003e and \u003cstrong\u003etwo terminal blocks\u003c\/strong\u003e with three terminals each.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJP1, JP2, and JP3\u003c\/strong\u003e handle MOV or AC line filter blown fuse indication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJP4 and JP7\u003c\/strong\u003e manage AC or DC side connection analog ground current sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJP5\u003c\/strong\u003e applies grounding resistor bridge voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJP6\u003c\/strong\u003e controls the SCR ripple filter.\u003c\/li\u003e\n\u003cli\u003eThe board also contains test points for diagnostic checks.\u003c\/li\u003e\n\u003cli\u003eInstall the board on standoffs on another drive component; signal wires originate on that component.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostics and Control Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccess the built-in diagnostic tool through the control panel menu to generate a health report.\u003c\/li\u003e\n\u003cli\u003eView the report on the control panel display or download it to a laptop for comparison before and after repairs.\u003c\/li\u003e\n\u003cli\u003eUse the menu-driven interface to upload and download files through a serial cable connection.\u003c\/li\u003e\n\u003cli\u003eEdit drive configuration parameters to define operating behavior.\u003c\/li\u003e\n\u003cli\u003eUse the keypad buttons to run, stop, speed up, or slow down the drive directly without changing parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the system input voltage falls within the 200–600 VAC range before installation.\u003c\/li\u003e\n\u003cli\u003eMount the \u003cstrong\u003eDS200LPPAG1AAA\u003c\/strong\u003e board on the designated standoffs on the drive component.\u003c\/li\u003e\n\u003cli\u003eConnect signal wires from the originating component to the board's terminal blocks.\u003c\/li\u003e\n\u003cli\u003eConfirm jumper settings (JP1–JP7) match your application requirements using the GEI-100178 manual.\u003c\/li\u003e\n\u003cli\u003eCheck all connections and test points before powering up the system.\u003c\/li\u003e\n\u003cli\u003eRun the diagnostic tool after installation to verify board health and function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePacking List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003eDS200LPPAG1AAA\u003c\/strong\u003e Line Protection Panel Board\u003c\/li\u003e\n\u003cli\u003e1 × Anti-static protective bag\u003c\/li\u003e\n\u003cli\u003e1 × Protective foam packaging\u003c\/li\u003e\n\u003cli\u003e1 × Cardboard shipping box\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship via FedEx, UPS, and DHL to worldwide destinations.\u003c\/li\u003e\n\u003cli\u003eWe dispatch orders within 5 business days after payment confirmation.\u003c\/li\u003e\n\u003cli\u003eWe accept returns within 30 days of delivery under our return policy.\u003c\/li\u003e\n\u003cli\u003eAll units are brand new and original.\u003c\/li\u003e\n\u003cli\u003eOur stock is available for immediate order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the input voltage range for the DS200LPPAG1AAA?\u003c\/strong\u003e\u003cbr\u003eA: The board operates on 200–600 VAC system input voltage, with a specified input range of 230–600 VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many input channels does this board support?\u003c\/strong\u003e\u003cbr\u003eA: It provides 12 input channels for signal processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The board operates reliably from 40°C to 85°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What output voltage does the board provide?\u003c\/strong\u003e\u003cbr\u003eA: The output is rated at 125 V DC, with a 28 V DC power supply voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I diagnose a faulty board?\u003c\/strong\u003e\u003cbr\u003eA: Use the control panel diagnostic menu to generate a health report and compare results before and after repairs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the DS200LPPAG1AAA in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we have this item in stock and ready to ship.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does shipping take?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 business days via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support returns within 30 days of delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner: NexAuto Technology Limited – \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48151652663457,"sku":"DS200LPPAG1AAA","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/DS200LPPAG1AAA.jpg?v=1792485228","url":"https:\/\/www.autonexcontrol.com\/products\/ds200lppag1aaa-ge-mark-v-line-protection-panel-board","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}