{"product_id":"ds200dtbbg1abb-ge-mark-v-terminal-board-digital-connector-card","title":"DS200DTBBG1ABB GE Mark V Terminal Board Digital Connector Card","description":"\u003ch2\u003e\u003cstrong\u003eGE DS200DTBBG1ABB – Mark V Terminal Board Digital Connector Card\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e DS200DTBBG1ABB from General Electric.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark V – functional revision 1A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Blocks:\u003c\/strong\u003e Two blocks (TB1 and TB2) with terminals for 95 signal wires each.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Signal Capacity:\u003c\/strong\u003e Up to 110 signal wires can connect to the terminal blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectors:\u003c\/strong\u003e Three 50-pin connectors with IDs JFF, JFG, and JFH.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Connectors:\u003c\/strong\u003e Bayonet connectors and five jumpers included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Coating:\u003c\/strong\u003e Normal coating for standard industrial protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Terminal Board Digital Connector Card \/ Contact Input Expansion Termination Module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConnector Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe three 40-pin connectors use IDs JFF, JFG, and JFH for clear identification.\u003c\/li\u003e\n\u003cli\u003eRecord which 40-pin ribbon cable connects to each connector during installation.\u003c\/li\u003e\n\u003cli\u003eConnecting ribbon cables to the wrong connectors requires a drive shutdown and restart.\u003c\/li\u003e\n\u003cli\u003eProper cable management prevents productivity loss and operator inconvenience.\u003c\/li\u003e\n\u003cli\u003eCompatible connectors include the JRR TCDA contact input connector.\u003c\/li\u003e\n\u003cli\u003eThe JY 125 V DC DTBA board power connector also works with this board.\u003c\/li\u003e\n\u003cli\u003eThe JRS\/T connector typically remains unused in most configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Block Wiring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTerminal block TB1 and terminal block TB2 each hold terminals for 95 signal wires.\u003c\/li\u003e\n\u003cli\u003eIndividual terminals are numbered sequentially on each terminal block.\u003c\/li\u003e\n\u003cli\u003eIdentify a specific terminal using the block ID and terminal number (e.g., TB1 90, TB2 48).\u003c\/li\u003e\n\u003cli\u003eTB1 90 means terminal 90 on terminal block 1.\u003c\/li\u003e\n\u003cli\u003eTB2 48 means terminal 48 on terminal block 2.\u003c\/li\u003e\n\u003cli\u003eDocument all signal wire connections to simplify future maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower down the drive system completely before installing or replacing the board.\u003c\/li\u003e\n\u003cli\u003eRecord the ribbon cable connections to JFF, JFG, and JFH before removal.\u003c\/li\u003e\n\u003cli\u003eConnect the 40-pin ribbon cables to the correct connectors during installation.\u003c\/li\u003e\n\u003cli\u003eSecure all terminal block wiring with proper torque specifications.\u003c\/li\u003e\n\u003cli\u003eRestart the drive and verify proper operation after board replacement.\u003c\/li\u003e\n\u003cli\u003eIncorrect cable connections require a full drive shutdown and rework.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x DS200DTBBG1ABB Terminal Board Digital Connector Card\u003c\/li\u003e\n\u003cli\u003eAnti-static packaging for safe transport\u003c\/li\u003e\n\u003cli\u003eProduct documentation and installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship via FedEx, UPS, or DHL – tracking number provided within 24 hours.\u003c\/li\u003e\n\u003cli\u003eAll items are new surplus stock, ready for immediate dispatch.\u003c\/li\u003e\n\u003cli\u003eDelivery within 5 business days after order confirmation.\u003c\/li\u003e\n\u003cli\u003e30-day return policy applies for unopened and undamaged products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this board new or refurbished?\u003c\/strong\u003e\u003cbr\u003eA: We supply new surplus units in factory packaging, never used.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the typical lead time for delivery?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days after order placement, with express courier options available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many signal wires can this board handle?\u003c\/strong\u003e\u003cbr\u003eA: The DS200DTBBG1ABB supports up to 110 signal wires across two terminal blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What are the connector IDs on this board?\u003c\/strong\u003e\u003cbr\u003eA: The three 40-pin connectors use IDs JFF, JFG, and JFH.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What happens if I connect ribbon cables to the wrong connectors?\u003c\/strong\u003e\u003cbr\u003eA: You must shut down the drive, move the cables to the correct connectors, and restart.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I identify specific terminals?\u003c\/strong\u003e\u003cbr\u003eA: Use the terminal block ID (TB1 or TB2) and the terminal number (e.g., TB1 90).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What voltage does the power connector use?\u003c\/strong\u003e\u003cbr\u003eA: The JY connector accepts 125 V DC for the DTBA board power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you offer technical support for installation?\u003c\/strong\u003e\u003cbr\u003eA: Yes, our team provides application notes and wiring diagrams; contact us for detailed assistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner NexAuto Technology Limited:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":46819080306849,"sku":"DS200DTBBG1ABB","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/DS200DTBBG1ABB.jpg?v=1785914179","url":"https:\/\/www.autonexcontrol.com\/products\/ds200dtbbg1abb-ge-mark-v-terminal-board-digital-connector-card","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}