{"product_id":"allen-bradley-150-f60nbdb-smc-flex-soft-starter-60a-460v","title":"Allen-Bradley 150-F60NBDB SMC Flex Soft Starter | 60A 460V","description":"\u003ch2\u003e\u003cstrong\u003eAllen-Bradley 150-F60NBDB SMC Flex Smart Motor Controller\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F60NBDB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController type:\u003c\/strong\u003e Soft starter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController rating:\u003c\/strong\u003e 60 A, 10–40 Hp @ 460 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl voltage:\u003c\/strong\u003e 100…240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operating voltage (Ue):\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated control supply voltage:\u003c\/strong\u003e 100 V at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload current (line connected):\u003c\/strong\u003e 12 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload current (delta connected):\u003c\/strong\u003e 20.8 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip classes:\u003c\/strong\u003e 10, 15, 20, and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip current rating:\u003c\/strong\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransformer control module:\u003c\/strong\u003e 75 VA @ 100…240 V AC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatsink fan rating:\u003c\/strong\u003e 20 VA @ 110\/120 V AC or 220\/240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive peak inverse voltage:\u003c\/strong\u003e 1400 V per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine connected motor power (max):\u003c\/strong\u003e 50 Hp @ 575 V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta connected motor power (max):\u003c\/strong\u003e 75 Hp @ 460 V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated impulse voltage:\u003c\/strong\u003e 6000 V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric withstand:\u003c\/strong\u003e 2500 V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine connected motor current:\u003c\/strong\u003e 12…60 A @ 500\/575 V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta connected motor current:\u003c\/strong\u003e 20.8…104 A @ 500\/575 V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient protection:\u003c\/strong\u003e Metal oxide varistors: 220 J (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation voltage:\u003c\/strong\u003e Rated 500 V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 200…480 V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-state current:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit protection device list:\u003c\/strong\u003e Standard fuse, circuit breaker, and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of contacts:\u003c\/strong\u003e 1 for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh capacity available fault current (max):\u003c\/strong\u003e 70 kA @ 600 V, max current 200 A time delay Class J or Class L fuse for inside delta connected motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of current (auxiliary contacts):\u003c\/strong\u003e AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional thermal current (Ith):\u003c\/strong\u003e AC\/DC 5 A for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of control circuit:\u003c\/strong\u003e Electromagnetic relay for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of contacts:\u003c\/strong\u003e Programmable NO\/NC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilization category:\u003c\/strong\u003e MG 1 per UL\/CSA\/NEMA for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard controller feature:\u003c\/strong\u003e Status indication: stopped, starting, stopping, at speed, alarm, and fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard available fault current (max):\u003c\/strong\u003e 10 kA @ 200…600 V, maximum standard fuse 400 A for delta device operational current rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional controller feature:\u003c\/strong\u003e SMB smart motor braking control: provides motor braking without additional equipment, braking current adjustable from 0…400% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated motor overload protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit protection device performance (SCPD) type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of sensors (max):\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush current control module:\u003c\/strong\u003e 5 A @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC terminals (RPTC = open), max:\u003c\/strong\u003e 30 V for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient watts control module:\u003c\/strong\u003e 60 W @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady state watts control module:\u003c\/strong\u003e 24 W @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC terminals (RPTC = 4 kΩ), max:\u003c\/strong\u003e \u0026lt;7.5 V for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e 800 ms for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush time control module:\u003c\/strong\u003e 250 ms @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient time control module:\u003c\/strong\u003e 500 ms @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold resistance of PTC sensor chain (max):\u003c\/strong\u003e 1500 Ω for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer input:\u003c\/strong\u003e 0…5 V DC @ 4.5 V DC = 100% Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllen-Bradley power supply control module (min):\u003c\/strong\u003e 1606-XLP50E @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit trip resistance:\u003c\/strong\u003e 25 Ω ± 10 Ω for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse resistance:\u003c\/strong\u003e 3400 Ω ± 150 Ω for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset resistance:\u003c\/strong\u003e 1600 Ω ± 100 Ω for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-state voltage (max):\u003c\/strong\u003e 50 V AC @ 10 V DC \/ 12 V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-state voltage (min):\u003c\/strong\u003e 85 V AC @ 19.2 V DC \/ 20.4 V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower line side cable size:\u003c\/strong\u003e 0.8…2.5 mm² (18…14 AWG) for power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower load side cable size:\u003c\/strong\u003e 0.8…2.5 mm² (18…14 AWG) for power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpper load side cable size:\u003c\/strong\u003e 2.5…50 mm² (14…1 AWG) for load power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpper line side cable size:\u003c\/strong\u003e 2.5…95 mm² (14…3 AWG) for line power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational current (auxiliary contacts):\u003c\/strong\u003e 3 A @ 120 V AC, 1.5 A @ 240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-state current:\u003c\/strong\u003e 20 mA @ 120 V AC \/ 40 mA @ 240 V AC, 7.6 mA @ 24 V AC\/DC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3), and 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady state heat dissipation with control and fan power:\u003c\/strong\u003e 97 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage and transportation temperature:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5…95% (noncondensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e Open: -5 to 50 °C (23 to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection against electrical shock:\u003c\/strong\u003e IP20 per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission levels:\u003c\/strong\u003e Radiated emission: Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity levels:\u003c\/strong\u003e Surge transient: per EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.7 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Operational: 15 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 150 mm (5.90 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 203 mm (8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 321 mm (12.60 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower pole construction:\u003c\/strong\u003e Heatsink thyristor modular design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Operational: 1.0 G peak, 0.15 mm (0.006 in) displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake:\u003c\/strong\u003e 3600 VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreak:\u003c\/strong\u003e 360 VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening torque:\u003c\/strong\u003e 14.7 Nm (130 in-lb) for power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal bypass:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Single direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower terminal markings:\u003c\/strong\u003e NEMA, CENELEC EN50 012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl terminals:\u003c\/strong\u003e Clamping yoke connection, M3 screw clamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire strip length:\u003c\/strong\u003e 18…20 mm (0.22…0.34 in) for power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl modules construction:\u003c\/strong\u003e Thermoset and thermoplastic moldings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetal parts construction:\u003c\/strong\u003e Plated brass, copper, or painted steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller vertically on a flat panel with adequate clearance.\u003c\/li\u003e\n\u003cli\u003eUse the specified cable sizes for line, load, and control terminals.\u003c\/li\u003e\n\u003cli\u003eTighten power terminals to 14.7 Nm (130 in-lb) using a calibrated torque wrench.\u003c\/li\u003e\n\u003cli\u003eConnect control voltage between 100 and 240 V AC to the designated terminals.\u003c\/li\u003e\n\u003cli\u003eEnsure the heatsink fan receives 20 VA at 110\/120 V AC or 220\/240 V AC.\u003c\/li\u003e\n\u003cli\u003eVerify the short-circuit protection device matches Class CC, J, or L fuses.\u003c\/li\u003e\n\u003cli\u003eProgram trip class and overload settings via the built-in display.\u003c\/li\u003e\n\u003cli\u003eCheck the PTC sensor chain resistance stays below 1500 Ω for proper detection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Allen-Bradley \u003cstrong\u003e150-F60NBDB\u003c\/strong\u003e SMC Flex Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e1 × Display module (integrated)\u003c\/li\u003e\n\u003cli\u003e1 × Mounting hardware kit\u003c\/li\u003e\n\u003cli\u003e1 × Terminal cover set\u003c\/li\u003e\n\u003cli\u003e1 × User manual (English)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the control voltage range for this soft starter?\u003c\/strong\u003e The \u003cstrong\u003e150-F60NBDB\u003c\/strong\u003e accepts 100…240 V AC control voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this controller with a delta-connected motor?\u003c\/strong\u003e Yes, it supports delta-connected motors up to 75 Hp at 460 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it include internal bypass?\u003c\/strong\u003e Yes, the internal bypass is true and reduces heat during run mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat trip classes are available?\u003c\/strong\u003e You can select trip classes 10, 15, 20, and 30.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum operating altitude?\u003c\/strong\u003e The controller operates safely up to 2000 meters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the product new and original?\u003c\/strong\u003e Yes, we ship brand-new original units from stock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow fast do you ship?\u003c\/strong\u003e We dispatch within 5 days using FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your return policy?\u003c\/strong\u003e We accept returns within 30 days of delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47919347400865,"sku":"150-F60NBDB","price":268.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F60NBDB.jpg?v=1790236707","url":"https:\/\/www.autonexcontrol.com\/products\/allen-bradley-150-f60nbdb-smc-flex-soft-starter-60a-460v","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}