{"product_id":"6ep1336-3ba10-siemens-psu8200-24vdc-20a-power-supply","title":"6EP1336-3BA10 Siemens PSU8200 24VDC 20A Power Supply","description":"\u003ch2\u003e\u003cstrong\u003eSiemens 6EP1336-3BA10 SITOP PSU8200 24V 20A Power Supply\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput voltage AC:\u003c\/strong\u003e 85 ... 275 V AC (rated 120-230 V) with wide-range capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput voltage DC:\u003c\/strong\u003e 88 ... 350 V DC (rated 110-220 V).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput voltage:\u003c\/strong\u003e 24 V DC rated, adjustable from 24 V to 28 V via potentiometer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput current:\u003c\/strong\u003e 20 A rated; derating applies above +60 °C (3% per K).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput power:\u003c\/strong\u003e 480 W typical active power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains buffering:\u003c\/strong\u003e minimum 20 ms at Vin = 230 V for rated load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual ripple:\u003c\/strong\u003e max 100 mV (typical 80 mV); voltage peak max 200 mV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit protection:\u003c\/strong\u003e selectable constant current (~21.5 A) or latching shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload capability:\u003c\/strong\u003e 150% Iout rated up to 5 seconds per minute.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage protection:\u003c\/strong\u003e clamps output below 31.8 V for safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus Signaling and Control Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal operation display:\u003c\/strong\u003e Green LED indicates \"24 V OK\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm signal output:\u003c\/strong\u003e Relay contact (NO, 60 V DC \/ 0.3 A) for remote monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote ON\/OFF:\u003c\/strong\u003e Terminals 15 and 16 provide external control capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload and fault display:\u003c\/strong\u003e Yellow LED for overload, red LED for latching shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft start behavior:\u003c\/strong\u003e No output voltage overshoot during power-on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse delay:\u003c\/strong\u003e maximum 1.5 s; voltage rise time typical 250 ms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Mechanical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -25 °C to +70 °C with natural convection; startup tested from -40 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage \/ transport temperature:\u003c\/strong\u003e -40 °C to +85 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClimate class:\u003c\/strong\u003e 3K3 per IEC 60721, 5–95% RH non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure dimensions:\u003c\/strong\u003e 90 mm width x 125 mm height x 125 mm depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.2 kg; mounts on DIN rail EN 60715 (35x7.5\/15).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired spacing:\u003c\/strong\u003e 50 mm top\/bottom, 0 mm left\/right for stacking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApprovals and Safety Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE marking, UKCA marking,\u003c\/strong\u003e \u003cstrong\u003eEAC\u003c\/strong\u003e, and \u003cstrong\u003eRCM\u003c\/strong\u003e conformity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus-Listed\u003c\/strong\u003e (UL 508, CSA C22.2 No. 107.1), File E197259; also cCSAus (CSA C22.2 No. 62368-1, UL 62368-1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBIS certification\u003c\/strong\u003e (R-41183539) and \u003cstrong\u003eCB certificate\u003c\/strong\u003e available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipbuilding approval:\u003c\/strong\u003e ABS (American Bureau of Shipping) and DNV (Det Norske Veritas) certified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEMI F47\u003c\/strong\u003e compliant for semiconductor equipment voltage sag immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation:\u003c\/strong\u003e SELV (ES1) output per EN 61204-7, transformer per EN 61558-2-16.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection class:\u003c\/strong\u003e IP20, with Class I insulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF at 40 °C:\u003c\/strong\u003e 583,500 hours for reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Connection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap the SITOP PSU8200 24V 20A directly onto a standard 35 mm DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput connection:\u003c\/strong\u003e Screw terminals for L, N, PE (0.2 ... 4 mm² single-core or finely stranded).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput connection:\u003c\/strong\u003e Two screw terminals each for + and - (0.2 ... 4 mm²).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary contacts:\u003c\/strong\u003e Terminals 13, 14 for alarm relay; terminals 15, 16 for Remote ON\/OFF.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel operation:\u003c\/strong\u003e You can connect up to 2 units of \u003cstrong\u003e6EP1336-3BA10\u003c\/strong\u003e for increased power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e For 1-phase: 10 A characteristic C. For 2-phase: Siemens 3RV2711-1HD10 (120 V) or 3RV2711-1ED10 (230 V).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush current:\u003c\/strong\u003e limited to max 20 A at 25 °C; I²t value max 5 A²·s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit behavior:\u003c\/strong\u003e Selectable between constant current (~21.5 A) or latching shutdown.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Siemens SITOP \u003cstrong\u003e6EP1336-3BA10\u003c\/strong\u003e power supply module.\u003c\/li\u003e\n\u003cli\u003eMultilingual quick-start guide (paper version).\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting clips (pre-installed).\u003c\/li\u003e\n\u003cli\u003eNo additional cables or adapters are included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Delivery\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship from our warehouse within 5 business days after order confirmation.\u003c\/li\u003e\n\u003cli\u003eCarrier options: FedEx, UPS, or DHL express services.\u003c\/li\u003e\n\u003cli\u003eAll units are brand new, original Siemens stock.\u003c\/li\u003e\n\u003cli\u003eWe offer a 30-day return window for unused items in original packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this power supply accept both AC and DC input?\u003c\/strong\u003e\u003cbr\u003eYes, the \u003cstrong\u003e6EP1336-3BA10\u003c\/strong\u003e accepts 85-275 V AC and 88-350 V DC with wide-range capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What happens during overload or short-circuit?\u003c\/strong\u003e\u003cbr\u003eYou can select constant current limiting (~21.5 A) or latching shutdown with automatic restart.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I connect this unit in parallel with another?\u003c\/strong\u003e\u003cbr\u003eYes, you can parallel up to 2 units for higher output current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this model have Remote ON\/OFF capability?\u003c\/strong\u003e\u003cbr\u003eYes, terminals 15 and 16 provide Remote ON\/OFF control for external switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the typical efficiency and power loss?\u003c\/strong\u003e\u003cbr\u003eEfficiency is 94%, with power loss around 31 W at full rated output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the output voltage adjustable?\u003c\/strong\u003e\u003cbr\u003eYes, use the front potentiometer to adjust from 24 V to 28 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eOperation from -25 °C to +70 °C; startup tested from -40 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have stock available?\u003c\/strong\u003e\u003cbr\u003eYes, we maintain ample stock for immediate shipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor inquiries, please contact our sales team:\u003c\/strong\u003e\u003cbr\u003eEmail: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone \/ WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner NexAuto Technology Limited:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":46978611937441,"sku":"6EP1336-3BA10","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/6EP1336-3BA10.jpg?v=1788766872","url":"https:\/\/www.autonexcontrol.com\/products\/6ep1336-3ba10-siemens-psu8200-24vdc-20a-power-supply","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}