{"product_id":"51202329-722-honeywell-experion-pks-c-cable","title":"51202329-722 Honeywell Experion PKS C Cable","description":"\u003ch2\u003e\u003cstrong\u003e51202329-722 Honeywell Experion PKS Series C I\/O Link Cable Pair\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: \u003cstrong\u003eHoneywell\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003e51202329-722\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSeries: Experion PKS Series C I\/O Link Cable\u003c\/li\u003e\n\u003cli\u003eType: I\/O Link Extension Cable Pair\u003c\/li\u003e\n\u003cli\u003eJacket: \u003cspan style=\"color: gray;\"\u003eGray\u003c\/span\u003e | Contents: 1× Cable A \u003cspan style=\"color: orange;\"\u003e(yellow label)\u003c\/span\u003e + 1× Cable B \u003cspan style=\"color: green;\"\u003e(green label)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndividual Cable Length: 36 inches (1000 mm)\u003c\/li\u003e\n\u003cli\u003eMaximum Total Length: 30 ft (9 m) per Honeywell grounding rules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSignal Speed: 750 KBaud Series C I\/O Link\u003c\/li\u003e\n\u003cli\u003eFunction: Links C300 IOTA ports to IOTAs\/IOMs or extends to another cabinet\u003c\/li\u003e\n\u003cli\u003eI\/O Links per Controller: 2 (IOL1 + IOL2)\u003c\/li\u003e\n\u003cli\u003eThroughput: 2000 Link Units per second for Series C I\/O\u003c\/li\u003e\n\u003cli\u003eMax I\/O Units per Link: 40 at 50 ms CEE cycle\u003c\/li\u003e\n\u003cli\u003eRedundancy: Supplied as a matched pair — both cables required for full redundancy\u003c\/li\u003e\n\u003cli\u003eCompatible IOTA Sizes: 6 in (152 mm), 9 in (229 mm), 12 in (305 mm)\u003c\/li\u003e\n\u003cli\u003eCertifications: EN 61326-1:2013 EMC, IEC\/EN 61010-1 Safety\/LVD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnect Cable A to IOL1A \/ IOL2A ports and Cable B to IOL1B \/ IOL2B ports on the C300 IOTA\u003c\/li\u003e\n\u003cli\u003ePlug the opposite ends into the corresponding ports on your IOTA or extension point\u003c\/li\u003e\n\u003cli\u003eNever exceed the maximum total length of 30 ft (9 m) in any installation\u003c\/li\u003e\n\u003cli\u003eAlways use both cables together to maintain full redundant operation\u003c\/li\u003e\n\u003cli\u003eRefer to Honeywell R301.1 and EP03-300-511 for full installation procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage \u0026amp; Delivery\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePackage Includes: One \u003cstrong\u003e51202329-722\u003c\/strong\u003e cable pair (Cable A + Cable B)\u003c\/li\u003e\n\u003cli\u003eCondition: Brand new, original factory packaging\u003c\/li\u003e\n\u003cli\u003eStock: In stock for immediate order processing\u003c\/li\u003e\n\u003cli\u003eDispatch: Ships within 5 business days after order confirmation\u003c\/li\u003e\n\u003cli\u003eShipping Methods: DHL, FedEx, UPS available\u003c\/li\u003e\n\u003cli\u003eReturns: 30-day return policy for unused items in original condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does this cable pair include exactly?\u003c\/strong\u003e\u003cbr\u003eA: One Cable A with yellow label and one Cable B with green label — both 36 inches long.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I buy Cable A or Cable B separately?\u003c\/strong\u003e\u003cbr\u003eA: Yes — individual cables are available. Order \u003cstrong\u003e51202329-722\u003c\/strong\u003e if you need both as a complete pair.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum length I can run these cables?\u003c\/strong\u003e\u003cbr\u003eA: Honeywell specifies a maximum total length of 30 feet (9 meters). Longer runs may cause signal issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this cable carry power or only data?\u003c\/strong\u003e\u003cbr\u003eA: It is a passive data cable only. It transmits the I\/O Link signal and requires no external power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many devices can one I\/O Link support?\u003c\/strong\u003e\u003cbr\u003eA: Each I\/O Link supports up to 40 I\/O units when running at a 50 ms CEE cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this cable with other controllers besides C300?\u003c\/strong\u003e\u003cbr\u003eA: This cable is designed specifically for the C300 Controller in the Experion PKS Series C system. Verify compatibility before use elsewhere.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49178664173729,"sku":"51202329-722","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/51202329-722.jpg?v=1795167091","url":"https:\/\/www.autonexcontrol.com\/products\/51202329-722-honeywell-experion-pks-c-cable","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}