{"product_id":"3500-61-133819-02-bently-nevada-rtd-tc-i-o-module","title":"3500\/61 133819-02 Bently Nevada RTD\/TC I\/O Module","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 133819-02 3500\/61 RTD\/TC Non-Isolated I\/O Module Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications Summary\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 133819-02 (3500\/61 RTD\/TC Non-Isolated I\/O Module with Internal Terminations)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 to 6 RTD or TC signals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD types:\u003c\/strong\u003e 100Ω Pt (0.00385\/0.00392), 120Ω Ni, 10Ω Cu\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTC types:\u003c\/strong\u003e E, J, K, T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecorder output:\u003c\/strong\u003e +4 to +20 mA, 0-600Ω load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 1 °C or 1 °F, 0.3662 µA per bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy (best case):\u003c\/strong\u003e ±1 °C at 25°C with external termination non-isolated standard rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -30°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 500Vdc system, 250Vdc channel-to-channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCyber security:\u003c\/strong\u003e Designed to meet IEC 62443\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional safety:\u003c\/strong\u003e SIL 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the 133819-02 new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we provide \u003cstrong\u003e100% new original\u003c\/strong\u003e Bently Nevada modules. No refurbished or counterfeit parts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many channels can this I\/O module handle?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e3500\/61\u003c\/strong\u003e accepts 1 to 6 RTD or TC transducer signals. You configure each channel individually via software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What happens if I short the recorder output?\u003c\/strong\u003e\u003cbr\u003eA: Short circuits on recorder outputs do not stop monitor operation. The device continues normal function without damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use Type E thermocouples at -100°C with this module?\u003c\/strong\u003e\u003cbr\u003eA: Only at ambient temperatures below +35°C. Above +35°C, the usable range reduces to -60°C to +1000°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which RTD type does Bently Nevada recommend?\u003c\/strong\u003e\u003cbr\u003eA: Bently Nevada recommends 100Ω platinum RTD with alpha 0.00385. This is the worldwide industrial standard for RTD measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have the 133819-02 in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we keep \u003cstrong\u003ethe 133819-02 in stock\u003c\/strong\u003e for immediate dispatch. Contact us for quantity availability and lead time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What alarm delays can I set?\u003c\/strong\u003e\u003cbr\u003eA: Alert delay ranges from 1 to 60 seconds in 1-second steps. Danger delay ranges from 1 to 60 seconds in 0.5-second steps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this I\/O module SIL2 certified?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003e3500\/61 RTD\/TC Non-Isolated I\/O Module\u003c\/strong\u003e meets SIL2 functional safety requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the difference between internal and external termination?\u003c\/strong\u003e\u003cbr\u003eA: Internal termination modules like the \u003cstrong\u003e133819-02\u003c\/strong\u003e have built-in terminations. External termination modules require separate termination panels for field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46531181543585,"sku":"3500\/61 133819-02","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/3500_61_133819-02.jpg?v=1781161034","url":"https:\/\/www.autonexcontrol.com\/products\/3500-61-133819-02-bently-nevada-rtd-tc-i-o-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}