{"product_id":"3500-60-01-01-bently-nevada-temperature-monitor","title":"3500\/60-01-01 Bently Nevada Temperature Monitor","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 3500\/60-01-01 Temperature Monitor\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003e3500\/60-01-01\u003c\/strong\u003e – RTD\/TC Non-isolated I\/O Module with Internal Terminations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e Accepts from 1 to 6 RTD or TC transducer signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 10 MΩ for each lead input, ensuring minimal loading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 7 watts nominal, efficient for continuous operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Current Source:\u003c\/strong\u003e 925 ±15 µA @ 25°C per transducer (single supply for 4-wire, dual for 3-wire).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecorder Output:\u003c\/strong\u003e +4 to +20 mA proportional to full-scale per channel; short-circuit proof.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e CSA\/NRTL\/C (Class 1, Div 2) for hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30°C to +65°C (-22°F to +150°F) with internal termination I\/O.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C (-40°F to +185°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% non-condensing for harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Dimensions (Monitor):\u003c\/strong\u003e 241.3 mm x 24.4 mm x 241.8 mm (1 full-height front slot).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Monitor module 0.91 kg; I\/O module 0.45 kg (internal barrier version 0.46 kg).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTransducer Compatibility \u0026amp; Measurement Ranges\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType E Thermocouple:\u003c\/strong\u003e -100 °C to +1000 °C (-148 °F to +1832 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType J Thermocouple:\u003c\/strong\u003e -18 °C to +760 °C (0 °F to +1400 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType K Thermocouple:\u003c\/strong\u003e -18 °C to +1370 °C (0 °F to +2498 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType T Thermocouple:\u003c\/strong\u003e -160 °C to +400 °C (-256 °F to +752 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100Ω Platinum RTD (α=0.00385):\u003c\/strong\u003e -200 °C to +850 °C (-328 °F to +1562 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100Ω Platinum RTD (α=0.00392):\u003c\/strong\u003e -200 °C to +700 °C (-328 °F to +1292 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120Ω Nickel RTD:\u003c\/strong\u003e -80 °C to +260 °C (-112 °F to +500 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10Ω Copper RTD:\u003c\/strong\u003e -100 °C to +260 °C (-148 °F to +500 °F).\u003c\/li\u003e\n\u003cli\u003eExternal barriers may reduce upper range limits for some RTD types.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Rack Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the \u003cstrong\u003e3500\/60-01-01\u003c\/strong\u003e in a 3500 series rack using one full-height front slot.\u003c\/li\u003e\n\u003cli\u003eMount the corresponding I\/O module in the rear slot (one per channel).\u003c\/li\u003e\n\u003cli\u003eConnect RTD or TC sensors to the I\/O module terminals.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for transducer signals to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eEnsure ambient temperature stays within -30 °C to +65 °C for reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental \u0026amp; Mechanical Durability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis system operates reliably in high-humidity conditions (95% non-condensing).\u003c\/li\u003e\n\u003cli\u003eShort-circuit protection on recorder outputs prevents damage during installation.\u003c\/li\u003e\n\u003cli\u003eWide storage temperature range from -40 °C to +85 °C.\u003c\/li\u003e\n\u003cli\u003eCSA\/NRTL\/C approval for Class 1, Div 2 hazardous areas.\u003c\/li\u003e\n\u003cli\u003eRobust design suitable for turbines, compressors, and generators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents (Each Unit)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003eBently Nevada 3500\/60-01-01\u003c\/strong\u003e Monitor Module.\u003c\/li\u003e\n\u003cli\u003e1 x RTD\/TC Non-isolated I\/O Module (internal terminations, rear slot).\u003c\/li\u003e\n\u003cli\u003eInstallation and configuration guide (hardcopy).\u003c\/li\u003e\n\u003cli\u003eFront panel label set and mounting hardware.\u003c\/li\u003e\n\u003cli\u003eNo certificate or warranty documentation included in the box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship worldwide via FedEx, UPS, or DHL express services.\u003c\/li\u003e\n\u003cli\u003eAll orders dispatch within 5 business days from our warehouse.\u003c\/li\u003e\n\u003cli\u003eProducts are brand new, in original factory packaging.\u003c\/li\u003e\n\u003cli\u003eReal-time tracking number provided upon shipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the \u003cstrong\u003e3500\/60-01-01\u003c\/strong\u003e compatible with 3-wire RTD sensors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports both 3-wire and 4-wire platinum, nickel, and copper RTDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the accuracy of this temperature monitor?\u003c\/strong\u003e\u003cbr\u003eA: Accuracy depends on transducer; the system provides high-precision measurement with 925 µA current source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this monitor with Type K thermocouples up to 1370°C?\u003c\/strong\u003e\u003cbr\u003eA: Yes, Type K range is -18 °C to +1370 °C (0 °F to +2498 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this module support external safety barriers?\u003c\/strong\u003e\u003cbr\u003eA: Yes, but some RTD ranges may be reduced; refer to the specification for details.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the recorder output range?\u003c\/strong\u003e\u003cbr\u003eA: +4 to +20 mA per channel, proportional to full-scale; outputs are short-circuit protected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have this item in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we maintain regular stock of the \u003cstrong\u003e3500\/60-01-01\u003c\/strong\u003e for immediate shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We accept returns within 30 days of delivery for unused, original-condition units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does delivery take?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 working days; delivery time depends on your location and chosen courier (FedEx, UPS, DHL).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top: 20px;\"\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46703899410593,"sku":"3500\/60-01-01","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/3500_60-01-01.jpg?v=1784173197","url":"https:\/\/www.autonexcontrol.com\/products\/3500-60-01-01-bently-nevada-temperature-monitor","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}