{"product_id":"330903-00-04-70-12-00-3300-nsv-probe-new-bently-nevada","title":"330903-00-04-70-12-00 3300 NSv Probe New Bently Nevada","description":"\u003ch2\u003e\u003cstrong\u003e330903-00-04-70-12-00 - 3300 NSv Proximity Probes by Bently Nevada\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear range:\u003c\/strong\u003e 1.5 mm (60 mils) from 0.25 mm to 1.75 mm target distance. Output voltage spans -1 to -13 Vdc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended gap setting:\u003c\/strong\u003e 1.0 mm (40 mils) for optimal linear performance and stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncremental scale factor (ISF):\u003c\/strong\u003e 7.87 V\/mm (200 mV\/mil) with +12.5%\/-20% interchangeability error.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeviation from best fit straight line (DSL):\u003c\/strong\u003e Less than ±0.06 mm (±2.3 mils) ensures high linearity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency response:\u003c\/strong\u003e 0 to 10 kHz with +0, -3 dB typical for up to 305 m (1000 ft) field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget size requirement:\u003c\/strong\u003e Minimum 8.9 mm (0.35 in) diameter; recommended minimum is 13 mm (0.5 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe tip material:\u003c\/strong\u003e Polyphenylene sulfide (PPS) for durability and chemical resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe case material:\u003c\/strong\u003e AISI 304 stainless steel (SST) providing robust mechanical protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -52°C to +177°C (-62°F to +351°F) for extreme industrial conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e Same wide range from -52°C to +177°C (-62°F to +351°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable type:\u003c\/strong\u003e 75 Ω coaxial with FEP insulation; FluidLoc cable with Miniature coaxial ClickLoc connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal probe length:\u003c\/strong\u003e 7.0 meters (23.0 feet) with connector protector included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread specification:\u003c\/strong\u003e M8X1 probe case without armor, unthreaded length 00 mm, overall case length 40 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe DC resistance (RPROBE):\u003c\/strong\u003e 5.9 ± 0.9 ohms from center conductor to outer conductor at 7.0 m length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtension cable DC resistance:\u003c\/strong\u003e Center conductor 0.220 Ω\/m, shield 0.066 Ω\/m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtension cable capacitance:\u003c\/strong\u003e 69.9 pF\/m (21.3 pF\/ft) typical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField wiring specification:\u003c\/strong\u003e 0.2 to 1.5 mm² (16 to 24 AWG), recommend three-conductor shielded triad cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum field wiring length:\u003c\/strong\u003e 305 meters (1000 feet) between the Proximitor Sensor and monitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum bend radius:\u003c\/strong\u003e 25.4 mm (1.0 in) even with stainless steel armor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended torque:\u003c\/strong\u003e Finger tight; maximum torque 0.56 N•m (5 in•lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector-to-connector torque for M8X1 case:\u003c\/strong\u003e Maximum 7.3 N•m (65 in•lb), recommended 5.1 N•m (45 in•lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure sealing:\u003c\/strong\u003e Viton O-ring design seals differential pressure between probe tip and case.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency approval:\u003c\/strong\u003e Option 00 not required for this standard part.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum length of thread engagement:\u003c\/strong\u003e 12 mm for M8x1 probe case thread.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this \u003cstrong\u003e330903-00-04-70-12-00\u003c\/strong\u003e brand new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply only new and original units in factory packing. No used or refurbished items.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have this \u003cstrong\u003e3300 NSv\u003c\/strong\u003e probe in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we maintain stock availability for this model. Please contact us for current quantities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the lead time for shipping?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 business days after order confirmation and payment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which carriers do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via DHL, FedEx, or UPS depending on your destination and preference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return this probe if it does not fit my application?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we support 30-day returns from delivery date, provided the item remains unused and in original packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the \u003cstrong\u003e3300 NSv\u003c\/strong\u003e compatible with older 3300 RAM extension cables?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is mechanically and electrically interchangeable with previous 3300 RAM probes and cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What makes FluidLoc cable different from standard cable?\u003c\/strong\u003e\u003cbr\u003eA: FluidLoc cable provides enhanced resistance to fluid ingress, ideal for wet or oil-rich environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What happens if the target shaft is smaller than 13 mm?\u003c\/strong\u003e\u003cbr\u003eA: The scale factor may change. You can reduce the gap to minimize this effect. See Figure 12 in the manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the probe require any agency approval for my region?\u003c\/strong\u003e\u003cbr\u003eA: This part (option -00) has no agency approval. Choose other options if certification is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e (WhatsApp)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner NexAuto Technology Limited :\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46530917826721,"sku":"330903-00-04-70-12-00","price":255.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/330903-00-04-70-12-00.jpg?v=1781149331","url":"https:\/\/www.autonexcontrol.com\/products\/330903-00-04-70-12-00-3300-nsv-probe-new-bently-nevada","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}