{"product_id":"330709-000-050-50-11-00-bently-nevada-11-mm-probe","title":"330709-000-050-50-11-00 | Bently Nevada | 11 mm Probe","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 330709-000-050-50-11-00 3300 XL 11 mm Proximity Probe\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e The probe operates with a linear range suitable for shaft vibration and position monitoring. It requires a minimum target diameter of 30.5 mm (flat surface) or 152 mm (shaft diameter).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Operating and storage temperature spans from -52°C to +177°C (-62°F to +351°F). Avoid exposing the probe below -34°C to prevent premature seal failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe DC Resistance:\u003c\/strong\u003e For the 5.0 meter length, resistance from center to outer conductor is \u003cstrong\u003e7.2 ± 0.8 ohms\u003c\/strong\u003e. This value ensures consistent signal transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable \u0026amp; Connector:\u003c\/strong\u003e The unit features a miniature coaxial ClickLoc connector with a protector. It uses a 75 Ω triaxial FEP insulated FluidLoc cable, available in 5.0 meter total length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Case \u0026amp; Tip:\u003c\/strong\u003e The case is AISI 304 stainless steel, while the tip uses polyphenylene sulfide (PPS). Thread size is M16x1.5 with a maximum engagement of 24 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Specifications:\u003c\/strong\u003e Maximum rated torque is \u003cstrong\u003e63.3 N•m\u003c\/strong\u003e for the probe case. Recommended installation torque is \u003cstrong\u003e21.1 N•m\u003c\/strong\u003e. Connector torque should be finger tight, with a maximum of 0.565 N•m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e The cable (with or without armor) tolerates a bend radius of 25.4 mm (1.0 inch). This flexibility simplifies routing in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e Option 00 indicates no specific agency approval is required for this configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTemperature Classification Schedule\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPL Ga and Gc:\u003c\/strong\u003e T1 at -55°C to +232°C; T2 at -55°C to +177°C; T3 at -55°C to +120°C; T4 at -55°C to +80°C; T5 at -55°C to +40°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPL Dc:\u003c\/strong\u003e T280°C at -55°C to +232°C; T225°C at -55°C to +177°C; T170°C at -55°C to +120°C; T130°C at -55°C to +80°C; T105°C at -55°C to +100°C; T90°C at -55°C to +40°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this probe new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, every \u003cstrong\u003e330709-000-050-50-11-00\u003c\/strong\u003e is brand new and factory-sealed from Bently Nevada.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the FluidLoc cable feature?\u003c\/strong\u003e\u003cbr\u003eA: FluidLoc cable provides enhanced protection against fluid ingress, ideal for harsh environments with oil or coolant exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What are the temperature class limits for this probe?\u003c\/strong\u003e\u003cbr\u003eA: Temperature classification varies by ambient temperature, ranging from -55°C to +232°C depending on the T-class selected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this probe with a different cable length?\u003c\/strong\u003e\u003cbr\u003eA: This 5.0 meter version is specifically calibrated for the five-meter Proximitor Sensor. Other lengths may affect accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the minimum target size required?\u003c\/strong\u003e\u003cbr\u003eA: The probe requires a flat target of at least 30.5 mm or a shaft diameter of 152 mm for proper cross-talk limitation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e, \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46770491326625,"sku":"330709-000-050-50-11-00","price":217.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/330709-000-050-50-11-00.jpg?v=1785232263","url":"https:\/\/www.autonexcontrol.com\/products\/330709-000-050-50-11-00-bently-nevada-11-mm-probe","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}