{"product_id":"2mll-ch2a-honeywell-serial-module-masterlogic-200","title":"2MLL-CH2A Honeywell Serial Module MasterLogic-200","description":"\u003ch2\u003e2MLL-CH2A Honeywell MasterLogic-200 Snet PLC Communication Module\u003c\/h2\u003e\n\u003ch3\u003eTechnical Specifications (Honeywell 2MLL-CH2A)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003e2MLL-CH2A\u003c\/strong\u003e Serial Communication Module for MasterLogic-200 Snet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Channels:\u003c\/strong\u003e Provides one RS-232C channel and one RS-422 (RS-485 compatible) channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModem Support:\u003c\/strong\u003e Supports modem connections with remote devices on the RS-232C port only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Settings (SoftMasterNM):\u003c\/strong\u003e Start Bit: 1. Data Bits: 7 or 8. Stop Bits: 1 or 2. Parity: Odd, Even, or None.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rate Options:\u003c\/strong\u003e Selectable from 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, to 115200 bps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynchronization \u0026amp; Transmission Distance:\u003c\/strong\u003e Uses asynchronous communication. RS-232C: 15 meters (extendable via modem). RS-422: 500 meters maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Configurations:\u003c\/strong\u003e RS-232C supports 1:1 connections. RS-422 supports 1:1, 1:N, and N:M configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStation Settings:\u003c\/strong\u003e Station number range: 0 to 31 (up to 32 stations total).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols \u0026amp; Services:\u003c\/strong\u003e Includes Modbus RTU\/ASCII slave, P2P (Modbus RTU\/ASCII master), and user-defined protocol master. Also supports SoftMaster I\/F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics \u0026amp; Indicators:\u003c\/strong\u003e Equipped with RUN, I\/F, TX, RX, and ERR LEDs. Offers auto-scan, frame monitor, link monitor, and loop back diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption \u0026amp; Weight:\u003c\/strong\u003e Consumes 310 mA of current. Weighs 119 grams.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Includes:\u003c\/strong\u003e One Honeywell \u003cstrong\u003e2MLL-CH2A\u003c\/strong\u003e module and a quick-start installation guide. The package does not include certificate information or a 12-month warranty statement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Steps:\u003c\/strong\u003e Power off the MasterLogic-200 system before installation. Insert the module into the designated Snet slot. Connect devices to the RS-232C or RS-422 ports as needed. Restore power and configure settings using SoftMaster-NM software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Information:\u003c\/strong\u003e We dispatch all orders through FedEx, UPS, or DHL for reliable delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat communication channels does the Honeywell 2MLL-CH2A provide?\u003c\/strong\u003e \u003cbr\u003eIt offers one RS-232C channel and one RS-422\/485 channel for flexible device connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the 2MLL-CH2A support modem connections?\u003c\/strong\u003e \u003cbr\u003eYes, the RS-232C port supports modem connections with remote devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat network configurations are available?\u003c\/strong\u003e \u003cbr\u003eRS-232C supports 1:1. RS-422 supports 1:1, 1:N, and N:M topologies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many stations can the 2MLL-CH2A handle?\u003c\/strong\u003e \u003cbr\u003eIt manages up to 32 stations with addresses from 0 to 31.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum transmission distance for each port?\u003c\/strong\u003e \u003cbr\u003eRS-232C reaches 15 meters (extendable via modem). RS-422 reaches 500 meters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat protocols does this module support?\u003c\/strong\u003e \u003cbr\u003eIt supports Modbus RTU\/ASCII slave, P2P master, and user-defined protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this product brand new and in stock?\u003c\/strong\u003e \u003cbr\u003eYes, we supply only brand new, original Honeywell modules with immediate availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your shipping and return policy?\u003c\/strong\u003e \u003cbr\u003eWe deliver within 5 business days using DHL, FedEx, or UPS. We also support a 30-day return policy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor inquiries, contact \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or call \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46831459336353,"sku":"2MLL-CH2A","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/2MLL-CH2A.jpg?v=1786090817","url":"https:\/\/www.autonexcontrol.com\/products\/2mll-ch2a-honeywell-serial-module-masterlogic-200","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}