{"product_id":"150-f625nbed-allen-bradley-smc-flex-625a-motor-controller","title":"150-F625NBED Allen-Bradley | SMC Flex 625A Motor Controller","description":"\u003ch2\u003e\u003cstrong\u003e150-F625NBED SMC Flex Smart Motor Controller – 625 A Soft Starter by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F625NBED\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Soft starter with internal bypass\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 625 A, 500 Hp @ 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage (Ue):\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e200...480V AC (-15%, +10%)\u003c\/strong\u003e\u003c\/span\u003e per UL\/CSA\/NEMA for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 100...120V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Control Supply Voltage:\u003c\/strong\u003e 110 V at both 50 Hz and 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current:\u003c\/strong\u003e 208 A for line connected devices; 283 A for delta connected devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Current:\u003c\/strong\u003e 208...625 A @ 600\/Y\/690V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Current:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e283...850 A @ 500\/575V AC, 3-phase\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Power, Max:\u003c\/strong\u003e 800 Hp @ 600V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Power, Max:\u003c\/strong\u003e 900 Hp @ 575V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Classes:\u003c\/strong\u003e 10, 15, 20 and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Current Rating:\u003c\/strong\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motor Overload Protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT Protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive Peak Inverse Voltage:\u003c\/strong\u003e 1400V per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Voltage:\u003c\/strong\u003e 6000V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Withstand:\u003c\/strong\u003e 2500V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e Rated 500V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Metal oxide varistors, 220 J (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection Device:\u003c\/strong\u003e Standard fuse, circuit breaker, and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity Available Fault Current, Max:\u003c\/strong\u003e 74 kA @ 600V with 1600 A time delay Class J or Class L fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Available Fault Current, Max:\u003c\/strong\u003e 70 kA @ 690V for maximum FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPD Type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilization Category:\u003c\/strong\u003e MG 1 per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControl and Monitoring Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Integrated display for easy setup and diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Options:\u003c\/strong\u003e Brake control available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Controller Feature:\u003c\/strong\u003e Status indication for stopped, starting, stopping, at speed, alarm, and fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Controller Feature:\u003c\/strong\u003e SMB smart motor braking control with adjustable braking current from 0...400% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Current:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Voltage, Max:\u003c\/strong\u003e 50V AC @ 10V DC\/12V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Voltage, Min:\u003c\/strong\u003e 85V AC @ 19.2V DC\/20.4V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Current:\u003c\/strong\u003e 20 mA @ 120V AC \/ 40 mA @ 240V AC, 7.6 mA @ 24V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Input:\u003c\/strong\u003e 0...5V DC @ 4.5V DC = 100% Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransformer Rating Control Module:\u003c\/strong\u003e 751 VA (recommended 800 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatsink Fan Rating:\u003c\/strong\u003e 150 VA @ 110\/120V AC or 220\/240V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAuxiliary Contacts and PTC Input Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Contacts:\u003c\/strong\u003e 1 for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Current:\u003c\/strong\u003e AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional Thermal Current (Ith):\u003c\/strong\u003e AC\/DC 5 A for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Control Circuit:\u003c\/strong\u003e Electromagnetic relay for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Contacts:\u003c\/strong\u003e Programmable NO\/NC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current:\u003c\/strong\u003e 3 A @ 120V AC, 1.5 A @ 240V AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3), and 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake:\u003c\/strong\u003e 3600 VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreak:\u003c\/strong\u003e 360 VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Sensors, Max:\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = open), Max:\u003c\/strong\u003e 30V for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = 4 kΩ), Max:\u003c\/strong\u003e \u0026lt;7.5V for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 800 ms for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Resistance of PTC Sensor Chain, Max:\u003c\/strong\u003e 1500 Ω for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Trip Resistance:\u003c\/strong\u003e 25 Ω ± 10 Ω for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e3400 Ω ± 150 Ω\u003c\/strong\u003e\u003c\/span\u003e for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Resistance:\u003c\/strong\u003e 1600 Ω ± 100 Ω for PTC input ratings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Physical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Heat Dissipation:\u003c\/strong\u003e 446 W with control and fan power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage and Transportation Temperature:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5...95% (noncondensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Open: -5 to 50 °C (23 to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Electrical Shock:\u003c\/strong\u003e IP00 (open device) per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Emission Levels:\u003c\/strong\u003e Radiated emission Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity Levels:\u003c\/strong\u003e Surge transient per EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Opsal 4 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Opsal 1.0 G peak, 0.15 mm (0.006 in) displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 179 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 596.9 mm (23.50 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 346.2 mm (13.63 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 1041.1 mm (41 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction and Terminal Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Pole Construction:\u003c\/strong\u003e Heatsink hockey puck thyristor modular design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Single direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Bypass:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Terminal Markings:\u003c\/strong\u003e NEMA, CENELEC EN50 012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Terminals:\u003c\/strong\u003e Clamping yoke connection, M3 screw clamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine\/Load Side Power Terminals:\u003c\/strong\u003e Two 13.5 mm (0.53 in) diam holes per power pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Modules Construction:\u003c\/strong\u003e Thermoset and thermoplastic moldings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetal Parts Construction:\u003c\/strong\u003e Plated brass, copper, or painted steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the controller rating of the 150-F625NBED?\u003c\/strong\u003e\u003cbr\u003eA: It rates 625 A and 500 Hp at 460V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which trip classes does this soft starter support?\u003c\/strong\u003e\u003cbr\u003eA: It supports trip classes 10, 15, 20, and 30.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The open device operates from -5 to 50 °C (23 to 122 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it include integrated motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, integrated motor overload protection is available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum altitude for installation?\u003c\/strong\u003e\u003cbr\u003eA: The maximum altitude is 2000 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many PTC sensors can I connect?\u003c\/strong\u003e\u003cbr\u003eA: You can connect up to 6 sensors for PTC input ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does delivery take?\u003c\/strong\u003e\u003cbr\u003eA: We dispatch within 5 days and delivery time depends on your location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we accept returns within 30 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the product new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, all products are brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e, \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47174095896737,"sku":"150-F625NBED","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F625NBED.jpg?v=1789108800","url":"https:\/\/www.autonexcontrol.com\/products\/150-f625nbed-allen-bradley-smc-flex-625a-motor-controller","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}