{"product_id":"150-f5nbdd-allen-bradley-5a-motor-controller","title":"150-F5NBDD Allen-Bradley 5A Motor Controller","description":"\u003ch2\u003e\u003cstrong\u003e150-F5NBDD SMC Flex Smart Motor Controller – 5 A Soft Starter by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F5NBDD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Soft starter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 5 A, 0.5–3.0 Hp @ 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 100…240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage Ue:\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Control Supply Voltage:\u003c\/strong\u003e 100 V at 50 Hz and 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current (Line Connected):\u003c\/strong\u003e 1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current (Delta Connected):\u003c\/strong\u003e 1.7 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Classes:\u003c\/strong\u003e 10, 15, 20 and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Current Rating:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e117% of motor FLC\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Current:\u003c\/strong\u003e 1…5 A @ 500\/575V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Current:\u003c\/strong\u003e 1.7…8.7 A @ 500\/575V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Power, max:\u003c\/strong\u003e 3 Hp @ 575V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Power, max:\u003c\/strong\u003e 7.5 Hp @ 575V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e Rated 500V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e 200…480V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Voltage:\u003c\/strong\u003e 6000V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Withstand:\u003c\/strong\u003e 2500V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT Protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive Peak Inverse Voltage:\u003c\/strong\u003e 1400V per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Metal oxide varistors: 220 J (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection Device List:\u003c\/strong\u003e Standard fuse, circuit breaker and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity Available Fault Current, max:\u003c\/strong\u003e 70kA @ 600V with 17.5 A time delay Class J or Class L fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Available Fault Current, max:\u003c\/strong\u003e 5kA @ 200…600V with maximum standard fuse 35 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControl and Monitoring Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWith Display:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Type for Actuating:\u003c\/strong\u003e AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Options:\u003c\/strong\u003e Brake control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Controller Feature:\u003c\/strong\u003e Status indication for stopped, starting, stopping, at speed, alarm and fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Controller Feature:\u003c\/strong\u003e SMB smart motor braking control with adjustable braking current from 0…400% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motor Overload Protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Protection Device Performance (SCPD) Type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Sensors, max:\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Control Module:\u003c\/strong\u003e 5A @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = open), max:\u003c\/strong\u003e 30V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Watts Control Module:\u003c\/strong\u003e 60 W @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Watts Control Module:\u003c\/strong\u003e 24 W @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = 4 kΩ), max:\u003c\/strong\u003e \u0026lt;7.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 800 ms for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Time Control Module:\u003c\/strong\u003e 250 ms @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Time Control Module:\u003c\/strong\u003e 500 ms @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Resistance of PTC Sensor Chain, max:\u003c\/strong\u003e 1500 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Input:\u003c\/strong\u003e 0…5V DC @ 4.5V DC = 100% Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllen Bradley Power Supply Control Module, min:\u003c\/strong\u003e 1606-XLP50E @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Trip Resistance:\u003c\/strong\u003e 25 Ω ± 10 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Resistance:\u003c\/strong\u003e 3400 Ω ± 150 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Resistance:\u003c\/strong\u003e 1600 Ω ± 100 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Voltage, max:\u003c\/strong\u003e 50V AC @ 10V DC\/12V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Voltage, min:\u003c\/strong\u003e 85V AC @ 19.2V DC\/20.4V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Current:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Current:\u003c\/strong\u003e 20mA @ 120V AC\/40mA @ 240V AC, 7.6mA @ 24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAuxiliary Contacts and Relay Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Contacts:\u003c\/strong\u003e 1 for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Current:\u003c\/strong\u003e AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional Thermal Current (Ith):\u003c\/strong\u003e AC\/DC: 5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Control Circuit:\u003c\/strong\u003e Electromagnetic relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Contacts:\u003c\/strong\u003e Programmable NO\/NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current:\u003c\/strong\u003e 3A @ 120V AC, 1.5A @ 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3) and 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake:\u003c\/strong\u003e 3600VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreak:\u003c\/strong\u003e 360VA for auxiliary contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eThermal, Environmental and Mechanical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Heat Dissipation with Control and Fan Power:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e70 W\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage and Transportation Temperature:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5…95% (noncondensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Open: -5 to 50 °C (23 to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Electrical Shock:\u003c\/strong\u003e IP20 per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Emission Levels:\u003c\/strong\u003e Radiated emission: Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity Levels:\u003c\/strong\u003e Surge transient per EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.7 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Opsal: 15 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 150 mm (5.90 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 203 mm (8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 321 mm (12.60 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F5NBDD?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e150-F5NBDD\u003c\/strong\u003e carries a 5 A controller rating and supports 0.5–3.0 Hp at 460V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this soft starter include integrated motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes integrated motor overload protection and supports trip classes 10, 15, 20 and 30.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does this model accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 100…240V AC control voltage and operates at 50\/60 Hz for the power circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this controller with delta connected motors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports delta connected motor current from 1.7…8.7 A at 500\/575V AC, 3-phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The open type unit operates from -5 to 50 °C (23 to 122 °F) with humidity from 5…95% noncondensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it come with a display?\u003c\/strong\u003e\u003cbr\u003eA: Yes, this SMC Flex controller includes a display for status indication and fault monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What cable size does the power terminal accept?\u003c\/strong\u003e\u003cbr\u003eA: The line side accepts 2.5…95 mm² (14…3 AWG) and the load side accepts 2.5…50 mm² (14…1 AWG).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the tightening torque for the power terminals?\u003c\/strong\u003e\u003cbr\u003eA: The power terminals require 14.7 Nm (130 in-lb) of tightening torque.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS and DHL, and we usually dispatch within 5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support 30-day returns. The product is brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information Inquiries\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmail: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhone \/ WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47645426450593,"sku":"150-F5NBDD","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F5NBDD.jpg?v=1789713555","url":"https:\/\/www.autonexcontrol.com\/products\/150-f5nbdd-allen-bradley-5a-motor-controller","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}