{"product_id":"150-f201ncr-allen-bradley-smc-flex-solid-state-controller-201a","title":"150-F201NCR Allen-Bradley SMC-Flex Solid State Controller 201A","description":"\u003ch2\u003e150‑F201NCR Allen‑Bradley SMC‑Flex Open Solid‑State Motor Controller\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003eCore power ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutput current: \u003cspan style=\"color: #cc0000; font-weight: 600;\"\u003e201 A\u003c\/span\u003e continuous\u003c\/li\u003e\n\u003cli\u003eMotor power: \u003cspan style=\"color: #cc0000; font-weight: 600;\"\u003e150 Hp at 460V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eLine input: 200‑575V AC, three‑phase, 50\/60 Hz (auto‑ranging)\u003c\/li\u003e\n\u003cli\u003eControl voltage: 24V AC\/DC (for 5‑480 A units)\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage: 500\/575V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eMotor \u0026amp; application flexibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMotor current range: 116‑348 A (depending on voltage)\u003c\/li\u003e\n\u003cli\u003eMaximum motor power: 250 kW at 50 Hz \/ 300 HP at 60 Hz\u003c\/li\u003e\n\u003cli\u003eCompatible with standard squirrel‑cage and six‑lead wye‑delta motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eStart and stop modes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeven selectable modes: \u003cspan style=\"color: #cc0000; font-weight: 600;\"\u003ecurrent limit, preset slow speed, dual ramp, soft stop, linear speed acceleration, full voltage, soft start\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgrammable via front keypad or communication\u003c\/li\u003e\n\u003cli\u003eSmooth acceleration and deceleration reduce mechanical stress\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eProtection \u0026amp; diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComprehensive fault detection: phase reversal, over\/undervoltage, jam, underload, open gate, power loss, stall, overload, voltage unbalance, communication fault, controller temperature, line fault\u003c\/li\u003e\n\u003cli\u003eExcessive starts per hour protection\u003c\/li\u003e\n\u003cli\u003eElectronic overload with selectable trip class\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eInterface \u0026amp; connectivity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne DPI communication port for HMI or network adapters\u003c\/li\u003e\n\u003cli\u003eBacklit LCD display (2 lines × 16 characters) with programming keypad\u003c\/li\u003e\n\u003cli\u003eFour fully programmable auxiliary contacts\u003c\/li\u003e\n\u003cli\u003eLED status indicators for quick system check\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eEnvironmental limits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature (open enclosure): \u003cspan style=\"color: #cc0000; font-weight: 600;\"\u003e-5 °C to +50 °C\u003c\/span\u003e (23 °F to 122 °F)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -20 °C to +75 °C (-4 °F to 167 °F)\u003c\/li\u003e\n\u003cli\u003eMaximum altitude: 2000 m without derating\u003c\/li\u003e\n\u003cli\u003eWeight: 32.00 lbs (14.51 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eInstallation guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount vertically on a flat surface inside a suitable enclosure\u003c\/li\u003e\n\u003cli\u003eAllow free air circulation; maintain 100 mm clearance top and bottom\u003c\/li\u003e\n\u003cli\u003eUse copper conductors rated for 75 °C minimum\u003c\/li\u003e\n\u003cli\u003eConnect line to L1, L2, L3 and motor to T1, T2, T3 – observe phase sequence\u003c\/li\u003e\n\u003cli\u003eControl wiring: 24V AC\/DC to terminals; use shielded cable for DPI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003ePackage contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAllen‑Bradley \u003cstrong\u003e150‑F201NCR\u003c\/strong\u003e SMC‑Flex controller (open style)\u003c\/li\u003e\n\u003cli\u003eQuick‑start guide and documentation CD\u003c\/li\u003e\n\u003cli\u003eMounting hardware kit and grounding lug\u003c\/li\u003e\n\u003cli\u003eDPI port protective cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eShipping \u0026amp; logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFast dispatch via \u003cstrong\u003eFedEx, UPS, or DHL\u003c\/strong\u003e within 5 working days\u003c\/li\u003e\n\u003cli\u003eAll units are \u003cstrong\u003ebrand new and original\u003c\/strong\u003e factory stock\u003c\/li\u003e\n\u003cli\u003e30‑day return privilege for unopened items in original packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions – 150‑F201NCR\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat type of motors can I use with the 150‑F201NCR?\u003c\/strong\u003e\u003cbr\u003eThe controller works with standard three‑phase squirrel‑cage induction motors and also with six‑lead wye‑delta motors. It supports both 50 Hz and 60 Hz supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I operate this unit on a 575V AC system?\u003c\/strong\u003e\u003cbr\u003eYes. The \u003cstrong\u003e150‑F201NCR\u003c\/strong\u003e accepts line voltages from 200V up to 575V AC, making it suitable for North American 480V and 575V industrial networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it include built‑in overload protection?\u003c\/strong\u003e\u003cbr\u003eAbsolutely. The \u003cstrong\u003e150‑F201NCR\u003c\/strong\u003e provides electronic overload protection (class selectable) plus stall, jam, underload, and voltage\/current unbalance detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat communication options does the DPI port offer?\u003c\/strong\u003e\u003cbr\u003eThe DPI port connects to optional modules for DeviceNet, Profibus, EtherNet\/IP, or CANopen. You can also attach a remote human‑machine interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the ambient limits during operation?\u003c\/strong\u003e\u003cbr\u003eFor reliable operation, keep ambient temperature between -5 °C and +50 °C. Storage range is -20 °C to +75 °C. Do not exceed 2000 m altitude.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I select different start modes?\u003c\/strong\u003e\u003cbr\u003eUse the front keypad and LCD menu to choose from seven modes (current limit, dual ramp, soft start, etc.). The \u003cstrong\u003e150‑F201NCR\u003c\/strong\u003e stores your settings permanently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the typical delivery time?\u003c\/strong\u003e\u003cbr\u003eWe maintain stock and ship within 5 days via FedEx, UPS, or DHL. All products are new and factory‑sealed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return the controller if it doesn't fit my panel?\u003c\/strong\u003e\u003cbr\u003eYes, we offer 30‑day returns for unopened, undamaged units. Please verify dimensions and rating before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top: 1.5em;\"\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca rel=\"noopener\" href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003cbr\u003ePartner \u003cstrong\u003eNexAuto Technology Limited\u003c\/strong\u003e: \u003ca rel=\"noopener\" href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45807527264417,"sku":"150-F201NCR","price":278.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F201NCR.jpg?v=1780975842","url":"https:\/\/www.autonexcontrol.com\/products\/150-f201ncr-allen-bradley-smc-flex-solid-state-controller-201a","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}