{"product_id":"150-f201nbrb-allen-bradley-smc-flex-soft-starter-201-a","title":"150-F201NBRB Allen-Bradley SMC Flex Soft Starter 201 A","description":"\u003ch2\u003e\u003cstrong\u003e150-F201NBRB SMC Flex Smart Motor Controller – 201 A Soft Starter by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F201NBRB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Soft Starter \/ Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 201 A, 75–150 Hp at 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage Ue:\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Control Supply Voltage:\u003c\/strong\u003e 24 V at 50 Hz and 60 Hz AC, 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current:\u003c\/strong\u003e 67 A for line connected devices, 116 A for delta connected devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Classes:\u003c\/strong\u003e 10, 15, 20 and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Current Rating:\u003c\/strong\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Power, Max:\u003c\/strong\u003e 75 Hp at 230V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Power, Max:\u003c\/strong\u003e 350 Hp at 575V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Current:\u003c\/strong\u003e 67–201 A at 600\/Y\/690V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Current:\u003c\/strong\u003e 116–348 A at 500\/575V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e Rated 500V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e 200–480V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Voltage:\u003c\/strong\u003e 6000V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Withstand:\u003c\/strong\u003e 2500V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT Protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive Peak Inverse Voltage:\u003c\/strong\u003e 1400V per UL\/CSA\/NEMA for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Metal oxide varistors 220 J (optional) for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection Device List:\u003c\/strong\u003e Standard fuse, circuit breaker and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity Available Fault Current, Max:\u003c\/strong\u003e 70 kA at 600V with 600 A time delay Class J or Class L fuse for inside delta connected motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Available Fault Current, Max:\u003c\/strong\u003e 70 kA at 690V for maximum FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motor Overload Protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Protection Device Performance (SCPD) Type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Sensors, Max:\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTC Input Ratings:\u003c\/strong\u003e Voltage at terminals max 30V (RPTC = open), max \u0026lt;7.5V (RPTC = 4 kΩ), response time 800 ms, cold resistance max 1500 Ω, short circuit trip resistance 25 Ω ± 10 Ω, response resistance 3400 Ω ± 150 Ω, reset resistance 1600 Ω ± 100 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Input:\u003c\/strong\u003e 0–5V DC at 4.5V DC = 100% Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Module Ratings:\u003c\/strong\u003e Inrush current 5A at 24V DC, transient watts 60 W at 24V DC, steady state watts 24 W at 24V DC, inrush time 250 ms at 24V DC, transient time 500 ms at 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e 1 contact, AC type, conventional thermal current 5 A, rated operational current 3A at 120V AC and 1.5A at 240V AC, make 3600VA, break 360VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3) and 33\/34 (Aux #4)\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F201NBRB?\u003c\/strong\u003e\u003cbr\u003eA: The controller rating is 201 A, and it supports 75–150 Hp at 460V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this soft starter include integrated motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the 150-F201NBRB includes integrated motor overload protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does this model require?\u003c\/strong\u003e\u003cbr\u003eA: It uses 24V AC\/DC for the control circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this controller for delta connected motors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports 116–348 A at 500\/575V AC for delta connected motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The open type unit operates from -5 to 50 °C (23 to 122 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the 150-F201NBRB in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we have it in stock and ship within 5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support 30-day returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this product new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47173933105313,"sku":"150-F201NBRB","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F201NBRB.jpg?v=1789106550","url":"https:\/\/www.autonexcontrol.com\/products\/150-f201nbrb-allen-bradley-smc-flex-soft-starter-201-a","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}