{"product_id":"150-f108nbrb-allen-bradley-smc-flex-soft-starter","title":"150-F108NBRB Allen-Bradley SMC Flex Soft Starter","description":"\u003ch2\u003e\u003cstrong\u003e150-F108NBRB SMC Flex Smart Motor Controller – 108 A Soft Starter by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F108NBRB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Soft Starter \/ Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 108 A, 20–75 Hp @ 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage (Ue):\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Control Supply Voltage:\u003c\/strong\u003e 24 V AC at 50\/60 Hz; 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current (Line Connected):\u003c\/strong\u003e 27 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current (Delta Connected):\u003c\/strong\u003e 47 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Soft starter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Options:\u003c\/strong\u003e Pump control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Classes:\u003c\/strong\u003e 10, 15, 20, and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Current Rating:\u003c\/strong\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransformer Control Module:\u003c\/strong\u003e 75VA @ 100–240V AC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatsink Fan Rating:\u003c\/strong\u003e 20VA @ 110\/120V AC or 220\/240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT Protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive Peak Inverse Voltage:\u003c\/strong\u003e 1400V per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Power (Max):\u003c\/strong\u003e 90 kW @ 690V\/Y AC, 50 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Power (Max):\u003c\/strong\u003e 90 kW @ 400\/415V AC, 50 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Voltage:\u003c\/strong\u003e 6000V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Withstand:\u003c\/strong\u003e 2500V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Current:\u003c\/strong\u003e 27–108 A @ 600\/Y\/690V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Current:\u003c\/strong\u003e 47–187 A @ 500\/575V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Metal oxide varistors: 220 J (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e Rated 500V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e 200–480V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Current:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection Device List:\u003c\/strong\u003e Standard fuse, circuit breaker, and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Contacts:\u003c\/strong\u003e 1 for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity Available Fault Current (Max):\u003c\/strong\u003e 70kA @ 600V, maximum current 300 A time delay Class J or Class L fuse for inside delta connected motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Current:\u003c\/strong\u003e AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional Thermal Current (Ith):\u003c\/strong\u003e AC\/DC: 5 A for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Control Circuit:\u003c\/strong\u003e Electromagnetic relay for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Contacts:\u003c\/strong\u003e Programmable NO\/NC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilization Category:\u003c\/strong\u003e MG 1 per UL\/CSA\/NEMA for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Controller Feature:\u003c\/strong\u003e Status indication: stopped, starting, stopping, at speed, alarm, and fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Available Fault Current (Max):\u003c\/strong\u003e 70kA @ 690V for maximum FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Controller Feature:\u003c\/strong\u003e SMB smart motor braking control – provides motor braking without additional equipment; braking current adjustable from 0–400% of motor full-load current rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Control Supply Voltage at DC:\u003c\/strong\u003e 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motor Overload Protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Protection Device Performance (SCPD) Type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Sensors (Max):\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Control Module:\u003c\/strong\u003e 5A @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = open), Max:\u003c\/strong\u003e 30V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Watts Control Module:\u003c\/strong\u003e 60 W @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Watts Control Module:\u003c\/strong\u003e 24 W @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = 4 kΩ), Max:\u003c\/strong\u003e \u0026lt;7.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 800 ms for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Time Control Module:\u003c\/strong\u003e 250 ms @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Time Control Module:\u003c\/strong\u003e 500 ms @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Resistance of PTC Sensor Chain (Max):\u003c\/strong\u003e 1500 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Input:\u003c\/strong\u003e 0–5V DC @ 4.5V DC = 100% Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllen Bradley Power Supply Control Module (Min):\u003c\/strong\u003e 1606-XLP50E @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Trip Resistance:\u003c\/strong\u003e 25 Ω ± 10 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Resistance:\u003c\/strong\u003e 3400 Ω ± 150 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Resistance:\u003c\/strong\u003e 1600 Ω ± 100 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Voltage (Max):\u003c\/strong\u003e 50V AC @ 10V DC\/12V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Voltage (Min):\u003c\/strong\u003e 85V AC @ 19.2V DC\/20.4V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current:\u003c\/strong\u003e 3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Current:\u003c\/strong\u003e 20mA @ 120V AC \/ 40mA @ 240V AC, 7.6mA @ 24V AC\/DC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3), and 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Heat Dissipation with Control and Fan Power:\u003c\/strong\u003e 91 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage and Transportation Temperature:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5–95% (noncondensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Open: -5 to 50 °C (23 to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Electrical Shock:\u003c\/strong\u003e IP2X (with terminal covers) per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Emission Levels:\u003c\/strong\u003e Radiated emission: Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity Levels:\u003c\/strong\u003e Surge transient: per EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 15 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Opsal: 5.5 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 196.4 mm (7.74 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 212.2 mm (8.35 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 443.7 mm (17.47 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Pole Construction:\u003c\/strong\u003e Heatsink hockey puck thyristor modular design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake:\u003c\/strong\u003e 3600VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreak:\u003c\/strong\u003e 360VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Bypass:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Single direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Terminal Markings:\u003c\/strong\u003e NEMA, CENELEC EN50 012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Terminals:\u003c\/strong\u003e Clamping yoke connection, M3 screw clamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine\/Load Side Power Terminals:\u003c\/strong\u003e One M10 x 1.5 diam hole per power pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Modules Construction:\u003c\/strong\u003e Thermoset and thermoplastic moldings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetal Parts Construction:\u003c\/strong\u003e Plated brass, copper, or painted steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Performance Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eOverload current for line connected devices:\u003c\/strong\u003e\u003c\/span\u003e 27 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eOverload current for delta connected devices:\u003c\/strong\u003e\u003c\/span\u003e 47 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eTrip classes:\u003c\/strong\u003e\u003c\/span\u003e 10, 15, 20, and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eTrip current rating:\u003c\/strong\u003e\u003c\/span\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #1976d2;\"\u003e\u003cstrong\u003eIntegrated motor overload protection:\u003c\/strong\u003e\u003c\/span\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #1976d2;\"\u003e\u003cstrong\u003eInternal bypass:\u003c\/strong\u003e\u003c\/span\u003e True\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F108NBRB?\u003c\/strong\u003e\u003cbr\u003eA: The controller handles 108 A for line connected motors and 47 A for delta connected motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which trip classes does this soft starter support?\u003c\/strong\u003e\u003cbr\u003eA: It supports trip classes 10, 15, 20, and 30.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The open-type controller operates from -5 to 50 °C (23 to 122 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this model include integrated motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003e150-F108NBRB\u003c\/strong\u003e includes integrated motor overload protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the rated control supply voltage?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 24 V AC at 50\/60 Hz and 24 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many auxiliary contacts does it provide?\u003c\/strong\u003e\u003cbr\u003eA: It provides one auxiliary contact with programmable NO\/NC configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support returns within 30 days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eWhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\" rel=\"noopener\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\" rel=\"noopener\" target=\"_blank\"\u003eNexAuto Technology Limited\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47173883035809,"sku":"150-F108NBRB","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F108NBRB.jpg?v=1789106179","url":"https:\/\/www.autonexcontrol.com\/products\/150-f108nbrb-allen-bradley-smc-flex-soft-starter","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}