{"product_id":"107770-04-02-new-bently-nevada-velocity-transducer-housing","title":"107770-04-02 New Bently Nevada Velocity Transducer Housing","description":"\u003ch2\u003e\u003cstrong\u003e107770-04-02 Bently Nevada Velocity Transducer Housing – CENELEC Approved\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003eBently Nevada\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e107770-04-02\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Velocity Transducer Housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Thread:\u003c\/strong\u003e 04 = 1\/2-14 BSP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Exit Fitting:\u003c\/strong\u003e 02 = 1\/2-14 NPT explosion-proof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Core:\u003c\/strong\u003e 330500 Velomitor Sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e 21128 Housing, preinstalled at the factory\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Rating:\u003c\/strong\u003e CENELEC Zone 1, Group IIC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx Safe Use:\u003c\/strong\u003e Zone 0\/1 and Zone 2 conditions apply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Complies with RoHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e Standard Velomitor velocity range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e Designed for industrial vibration monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e Matched to 330500 Velomitor specifications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e Stable output across the operating range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e Suited to continuous machine protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e Dependent on sensor and housing limits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Built for harsh industrial areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterference Resistance:\u003c\/strong\u003e Supports reliable signal transmission\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHazardous Area Conditions of Safe Use\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZone 0\/1: Connect the equipment to circuits that meet the listed entity parameters.\u003c\/li\u003e\n\u003cli\u003eZone 0\/1: Use Type A or Type B cables that comply with EN 60079-25.\u003c\/li\u003e\n\u003cli\u003eZone 0\/1: The cable parameters must respect the entity parameters.\u003c\/li\u003e\n\u003cli\u003eZone 2: The supply electrical parameters must not exceed the values in the tables.\u003c\/li\u003e\n\u003cli\u003eATEX and IECEx standards govern the safe installation and operation conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the mounting thread matches the 1\/2-14 BSP option before installation.\u003c\/li\u003e\n\u003cli\u003eCheck the cable exit fitting against the 1\/2-14 NPT explosion-proof option.\u003c\/li\u003e\n\u003cli\u003eConfirm the hazardous area rating suits CENELEC Zone 1, Group IIC.\u003c\/li\u003e\n\u003cli\u003eConnect the unit to compatible equipment that meets the entity parameters.\u003c\/li\u003e\n\u003cli\u003eUse approved Type A or Type B cable in line with EN 60079-25.\u003c\/li\u003e\n\u003cli\u003eKeep Zone 2 supply values within the limits shown in the tables.\u003c\/li\u003e\n\u003cli\u003eMount the housing securely to reduce mechanical stress on the sensor.\u003c\/li\u003e\n\u003cli\u003eRoute cabling away from heavy electrical noise where possible.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePacking List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003eBently Nevada 107770-04-02\u003c\/strong\u003e Velocity Transducer Housing\u003c\/li\u003e\n\u003cli\u003e1 × Preinstalled 330500 Velomitor Sensor\u003c\/li\u003e\n\u003cli\u003e1 × Preinstalled 21128 Housing\u003c\/li\u003e\n\u003cli\u003e1 × Factory packing as supplied by the manufacturer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping Methods\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx\u003c\/li\u003e\n\u003cli\u003eUPS\u003c\/li\u003e\n\u003cli\u003eDHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the mounting thread option for the 107770-04-02?\u003c\/strong\u003e\u003cbr\u003eA: The 04 option means 1\/2-14 BSP mounting thread.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What cable exit fitting does this model use?\u003c\/strong\u003e\u003cbr\u003eA: The 02 option provides a 1\/2-14 NPT explosion-proof fitting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which sensor and housing does this assembly include?\u003c\/strong\u003e\u003cbr\u003eA: It combines the 330500 Velomitor Sensor and the 21128 Housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What hazardous area rating does this unit carry?\u003c\/strong\u003e\u003cbr\u003eA: It is rated for CENELEC Zone 1, Group IIC applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What cable type should I use in Zone 0 or Zone 1?\u003c\/strong\u003e\u003cbr\u003eA: Use Type A or Type B cable that complies with EN 60079-25.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this product comply with RoHS?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it follows RoHS Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the product new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is brand new and original in factory packing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have stock available?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we keep stock available for this item.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days after order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which logistics carriers do you use?\u003c\/strong\u003e\u003cbr\u003eA: We commonly use DHL, FedEx, and UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support returns within 30 days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhone \/ WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47653097046177,"sku":"107770-04-02","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/107770-04-02.jpg?v=1789718428","url":"https:\/\/www.autonexcontrol.com\/products\/107770-04-02-new-bently-nevada-velocity-transducer-housing","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}