{"product_id":"ic694mdl734-ge-fanuc-dc-voltage-output-module","title":"IC694MDL734 GE Fanuc DC Voltage Output Module","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC694MDL734 6-Point DC Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #b22222;\"\u003e125V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #b22222;\"\u003e10.8 to 150 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #b22222;\"\u003e1 Amp per point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #b22222;\"\u003e7 Amps for 100 ms\u003c\/span\u003e (2% duty cycle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #b22222;\"\u003e5 to 7 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #b22222;\"\u003e90 mA from 5V backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eIsolation and Protection Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane to Frame Ground (Continuous)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #b22222;\"\u003e250V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane to Frame Ground (Withstand)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #b22222;\"\u003e1500V AC for 1 minute\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoint-to-Point Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #b22222;\"\u003e250V AC continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Points:\u003c\/strong\u003e 6 independent DC output channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Support:\u003c\/strong\u003e Both positive and negative logic operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Capacity:\u003c\/strong\u003e \u003cspan style=\"color: #b22222;\"\u003e1A\u003c\/span\u003e continuous per output point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Handling:\u003c\/strong\u003e Manages high startup currents effectively\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Speed:\u003c\/strong\u003e Fast \u003cspan style=\"color: #b22222;\"\u003e5-7 ms\u003c\/span\u003e switching for precise control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Fits any available slot in RX3i system racks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Requires proper termination and cable management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonnel:\u003c\/strong\u003e Should be installed by qualified technicians\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Follow all electrical safety codes and standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Set up through RX3i programming software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Flexibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Options:\u003c\/strong\u003e Positive and negative logic programming\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e Wide \u003cspan style=\"color: #b22222;\"\u003e10.8-150VDC\u003c\/span\u003e operating span\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Types:\u003c\/strong\u003e Suitable for various DC loads and devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Use:\u003c\/strong\u003e Ideal for factory automation and control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Compatible with full RX3i platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Standard industrial temperature range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Tolerance:\u003c\/strong\u003e Suitable for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e Designed for stable operation in vibration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e Built to withstand industrial shocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Adequate for control cabinet installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging and Availability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new, factory original GE Fanuc product\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStock Status:\u003c\/strong\u003e Immediately available from our inventory\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e Processed within 5 business days via major carriers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, and DHL available for delivery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReturns:\u003c\/strong\u003e 30-day return policy for unused products\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eHow many output points does the IC694MDL734 have?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe module provides 6 independent DC output points, each capable of switching \u003cspan style=\"color: #b22222;\"\u003e1A\u003c\/span\u003e at \u003cspan style=\"color: #b22222;\"\u003e125VDC\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eWhat is the operating voltage range?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC694MDL734\u003c\/strong\u003e operates from \u003cspan style=\"color: #b22222;\"\u003e10.8 to 150 VDC\u003c\/span\u003e with \u003cspan style=\"color: #b22222;\"\u003e125VDC\u003c\/span\u003e rated voltage.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eWhat isolation protection is provided?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIt features \u003cspan style=\"color: #b22222;\"\u003e250V AC\u003c\/span\u003e continuous isolation and \u003cspan style=\"color: #b22222;\"\u003e1500V AC\u003c\/span\u003e withstand capability.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCan I use both positive and negative logic?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eYes, the module supports both positive and negative logic operation for application flexibility.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eWhat is the response time for output switching?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eOutputs switch within \u003cspan style=\"color: #b22222;\"\u003e5 to 7 milliseconds\u003c\/span\u003e for responsive control.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eHow much power does it draw from the backplane?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe module consumes \u003cspan style=\"color: #b22222;\"\u003e90 mA\u003c\/span\u003e from the 5V backplane power supply.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139262472353,"sku":"IC694MDL734","price":206.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC694BEM331__E5_89_AF_E6_9C_AC__E5_89_AF_E6_9C_AC.jpg?v=1758191852","url":"https:\/\/www.autonexcontrol.com\/pl\/products\/ic694mdl734-ge-fanuc-dc-voltage-output-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}