{"product_id":"ic660ebd021-genius-i-o-block-ge-fanuc","title":"IC660EBD021 Genius I\/O Block GE Fanuc","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc Genius IC660BBD021 Discrete I\/O Block\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Manufacturer:\u003c\/strong\u003e GE Fanuc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Complete \u003cstrong\u003eIC660BBD021\u003c\/strong\u003e I\/O Block Module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Type:\u003c\/strong\u003e 16-channel Sinking Discrete I\/O.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24\/48 Volts DC (field supplied).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Flexibility:\u003c\/strong\u003e Each of the \u003cspan style=\"color: #2e74b5;\"\u003e16 circuits is user-configurable\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e \u003cspan style=\"color: #2e74b5;\"\u003e2 Amperes per circuit\u003c\/span\u003e steady state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e 10 Amperes maximum for 10 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Block Current:\u003c\/strong\u003e Does not exceed 15 Amperes at 35°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 1500 Volts block-to-block isolation.\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Characteristics \u0026amp; Timing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON Voltage (24VDC):\u003c\/strong\u003e 0-8 VDC. OFF Voltage: 17-24 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON Voltage (48VDC):\u003c\/strong\u003e 0-16 VDC. OFF Voltage: 34-48 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Processing Time:\u003c\/strong\u003e 1.7 ms base, plus configurable filter delay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Switching:\u003c\/strong\u003e Maximum frequency of once per second.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput On Delay:\u003c\/strong\u003e Approximately 1 millisecond.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Dropout Time:\u003c\/strong\u003e 10 milliseconds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features \u0026amp; Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Diagnostics:\u003c\/strong\u003e Monitors system health continuously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Diagnostics:\u003c\/strong\u003e Open wire, overtemperature, and failed switch detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Diagnostics:\u003c\/strong\u003e Short circuit, overload, no-load, failed switch, and overtemperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Built-in electronic short-circuit and over-temperature protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Parameters:\u003c\/strong\u003e Output pulse test, input filter time, and power-up state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Features:\u003c\/strong\u003e Outputs can be set to \"hold last state\" or a safe default.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Indicators:\u003c\/strong\u003e Front-panel LEDs for I\/O Enabled, Unit OK, and per-circuit status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"sink I\/O\" mean?\u003c\/strong\u003e\u003cbr\u003eIn a sinking module, the outputs provide a path to ground (DC-). The field device must be connected to the positive voltage source (DC+).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use one circuit as an input and another as an output?\u003c\/strong\u003e\u003cbr\u003eYes! The key feature of the \u003cstrong\u003eIC660BBD021\u003c\/strong\u003e is that \u003cspan style=\"color: #2e74b5;\"\u003eall 16 circuits are individually configurable\u003c\/span\u003e as inputs or outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo I need a separate power supply for the sensors?\u003c\/strong\u003e\u003cbr\u003eNo. The block provides power to the connected circuits; field output devices supply the 24\/48VDC source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I configure the module?\u003c\/strong\u003e\u003cbr\u003eUse a Genius Hand-Held Monitor (HHM) connected to the dedicated port on the block's front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is a tristate input?\u003c\/strong\u003e\u003cbr\u003eIt is an input mode that allows the detection of an open wire fault in addition to the ON\/OFF state, requiring an external resistor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45555602882721,"sku":"IC660EBD021","price":210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC660BBD024_03c02006-90b9-4800-8a81-ccd9509e8794.jpg?v=1766136797","url":"https:\/\/www.autonexcontrol.com\/pl\/products\/ic660ebd021-genius-i-o-block-ge-fanuc","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}