{"product_id":"ge-fanuc-ic200mdd851-discrete-i-o-module","title":"GE Fanuc IC200MDD851 Discrete I\/O Module","description":"\u003ch2\u003eGE Fanuc IC200MDD851: Flexible Logic Control Module\u003c\/h2\u003e\n\u003ch3\u003eModule Overview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e:GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series\u003c\/strong\u003e: Versamax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number\u003c\/strong\u003e: \u003cstrong\u003eIC200MDD851\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type\u003c\/strong\u003e: Discrete I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Capacity\u003c\/strong\u003e: \u003cspan style=\"color: #c0392b;\"\u003e16 I\/O Points\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChannel Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup Structure\u003c\/strong\u003e: 2 Groups of 8 Points Each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Logic\u003c\/strong\u003e: \u003cspan style=\"color: #2980b9;\"\u003ePositive or Negative Logic\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type\u003c\/strong\u003e: \u003cspan style=\"color: #27ae60;\"\u003eSourcing \/ Positive Logic\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Source\u003c\/strong\u003e: External Power for Outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Processing\u003c\/strong\u003e: NIU or CPU Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eData Handling Capacity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Input Data\u003c\/strong\u003e: \u003cspan style=\"color: #2980b9;\"\u003e4 bits\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Output Data\u003c\/strong\u003e: \u003cspan style=\"color: #27ae60;\"\u003e8 bits\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Processing\u003c\/strong\u003e: Intelligent NIU\/CPU Control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Integrity\u003c\/strong\u003e: Reliable Signal Transmission\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVisual Status Indicators\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Status LEDs\u003c\/strong\u003e: Show Current Input State\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Status LEDs\u003c\/strong\u003e: Display Output Conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Indicator\u003c\/strong\u003e: Green LED for Field Power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDependency\u003c\/strong\u003e: Requires Field and Backplane Power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring\u003c\/strong\u003e: Comprehensive Status Visibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e: Versatile Logic Support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Configuration\u003c\/strong\u003e: Sourcing Type Operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements\u003c\/strong\u003e: External Output Power Source\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration\u003c\/strong\u003e: Seamless Versamax Compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Standard Versamax Backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Grouped Point Configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Flexible Logic Settings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning\u003c\/strong\u003e: Quick Setup Process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Flexibility\u003c\/strong\u003e: Positive\/Negative Input Options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Reliability\u003c\/strong\u003e: Sourcing Output Design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Clarity\u003c\/strong\u003e: Comprehensive LED Indicators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration\u003c\/strong\u003e: NIU\/CPU Processing Power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Efficiency\u003c\/strong\u003e: Compact 16-Point Design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Summary\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: GE Intelligent Platforms\/GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: Versamax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: \u003cstrong\u003eIC200MDD851\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Discrete I\/O Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Points\u003c\/strong\u003e: \u003cspan style=\"color: #c0392b;\"\u003e16\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Types\u003c\/strong\u003e: Positive \/ Negative Logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Types\u003c\/strong\u003e: Sourcing \/ Positive Logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Input Data\u003c\/strong\u003e: \u003cspan style=\"color: #2980b9;\"\u003e4 bits\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Output Data\u003c\/strong\u003e: \u003cspan style=\"color: #27ae60;\"\u003e8 bits\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat logic types does the module support?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eIC200MDD851\u003c\/strong\u003e supports both \u003cspan style=\"color: #2980b9;\"\u003epositive and negative logic\u003c\/span\u003e for input connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow are the I\/O points organized?\u003c\/strong\u003e\u003cbr\u003eThe \u003cspan style=\"color: #c0392b;\"\u003e16 points\u003c\/span\u003e are split into two groups of eight points each for organized wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat processing unit is required?\u003c\/strong\u003e\u003cbr\u003eThe module requires a Versamax NIU or CPU for intelligent data processing and control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many data bits does it handle?\u003c\/strong\u003e\u003cbr\u003eIt processes \u003cspan style=\"color: #2980b9;\"\u003e4 bits of discrete input\u003c\/span\u003e and \u003cspan style=\"color: #27ae60;\"\u003e8 bits of discrete output\u003c\/span\u003e data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat do the LED indicators show?\u003c\/strong\u003e\u003cbr\u003eLEDs display input\/output status and a green power LED indicates field power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs external power required?\u003c\/strong\u003e\u003cbr\u003eYes, outputs require an external power source for proper operation and switching.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor technical specifications and ordering information:\u003c\/em\u003e \u003cstrong\u003e\u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139256115361,"sku":"IC200MDD851","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC200MDD851.jpg?v=1763622346","url":"https:\/\/www.autonexcontrol.com\/pl\/products\/ge-fanuc-ic200mdd851-discrete-i-o-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}