{"product_id":"do810-digital-output-module-16-channel-abb","title":"DO810 Digital Output Module | 16-Channel ABB","description":"\u003ch2\u003eABB DO810 16-Channel 24V Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e8b57;\"\u003eABB\u003c\/strong\u003e \u003cstrong style=\"color: #2e8b57;\"\u003eDO810\u003c\/strong\u003e module provides sixteen digital outputs for S800 I\/O systems. It delivers 0.5A per channel with comprehensive protection features. This robust module ensures reliable operation in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eSixteen 24V DC output channels\u003c\/span\u003e with current sourcing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eTwo isolated groups\u003c\/span\u003e with eight channels each\u003c\/li\u003e\n\u003cli\u003eDual voltage supervision inputs (one per group)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e0.5A maximum continuous current\u003c\/span\u003e per channel\u003c\/li\u003e\n\u003cli\u003eOutput Status Protection (OSP) functionality\u003c\/li\u003e\n\u003cli\u003eShort-circuit and over-temperature protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003eABB\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003eDO810\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle Number:\u003c\/strong\u003e 3BSE008510R1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e10-30V DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e0.5A maximum per channel\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Load:\u003c\/strong\u003e \u0026lt; 0.4 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Two groups, 8 channels each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Short-circuit, over-voltage, over-temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Cable Length:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e600 meters\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 2.1 Watts typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eShort-circuit protection\u003c\/span\u003e to ground and 30V\u003c\/li\u003e\n\u003cli\u003eOver-voltage and over-temperature protection\u003c\/li\u003e\n\u003cli\u003eCurrent limiting on all output channels\u003c\/li\u003e\n\u003cli\u003eOutput Status Protection (OSP) for error states\u003c\/li\u003e\n\u003cli\u003eAutomatic thermal shutdown protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostics \u0026amp; Monitoring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFront panel status LEDs (Fault, Run, Warning, OSP)\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e8b57;\"\u003eSixteen channel status indicators\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eDual process voltage supervision\u003c\/li\u003e\n\u003cli\u003eModule Error and Warning indications\u003c\/li\u003e\n\u003cli\u003eChannel error signals via ModuleBus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with S800 I\/O systems\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e8b57;\"\u003e0.5-0.6 Nm recommended torque\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e6-7.5 mm wire stripping length\u003c\/li\u003e\n\u003cli\u003eSupports standard wire sizes\u003c\/li\u003e\n\u003cli\u003eEasy integration with ABB MTUs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e8b57;\"\u003eOperating Temperature: 0 to +55°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40 to +70°C\u003c\/li\u003e\n\u003cli\u003eProtection Class: IP20\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5 to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003eHazardous location certifications available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Dimensions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 45 mm (1.77”)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 102 mm (4.01”)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 119 mm (4.7”)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.18 kg (0.4 lbs.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for S800 I\/O platform\u003c\/li\u003e\n\u003cli\u003eWorks with TU810, TU812, TU814 series\u003c\/li\u003e\n\u003cli\u003eCompatible with TU830 models\u003c\/li\u003e\n\u003cli\u003eKeying code: AA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSecure industrial packaging\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e8b57;\"\u003eWorldwide shipping via FedEx, UPS, DHL\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eComplete documentation included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat protection features does the DO810 offer?\u003c\/h4\u003e\n\u003cp\u003eThe module provides \u003cspan style=\"color: #2e8b57;\"\u003eshort-circuit, over-voltage, and over-temperature protection\u003c\/span\u003e on all channels.\u003c\/p\u003e\n\u003ch4\u003eWhat is the maximum output current per channel?\u003c\/h4\u003e\n\u003cp\u003eEach channel can deliver \u003cspan style=\"color: #2e8b57;\"\u003e0.5A continuous current\u003c\/span\u003e with current limiting.\u003c\/p\u003e\n\u003ch4\u003eHow does the Output Status Protection work?\u003c\/h4\u003e\n\u003cp\u003eOSP automatically \u003cspan style=\"color: #2e8b57;\"\u003esets outputs to predetermined states\u003c\/span\u003e upon error detection.\u003c\/p\u003e\n\u003ch4\u003eWhat is the output voltage range?\u003c\/h4\u003e\n\u003cp\u003eThe module operates with \u003cspan style=\"color: #2e8b57;\"\u003e10-30V DC output voltage\u003c\/span\u003e range.\u003c\/p\u003e\n\u003ch4\u003eHow many isolation groups are provided?\u003c\/h4\u003e\n\u003cp\u003eThere are \u003cspan style=\"color: #2e8b57;\"\u003etwo isolated groups\u003c\/span\u003e with eight output channels in each group.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eCopyright © 2025 AutoNex Controls Limited. All rights reserved.\u003c\/p\u003e\n\u003cp\u003eReference Source: \u003ca href=\"https:\/\/www.autonexcontrol.com\/\"\u003ewww.autonexcontrol.com\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eContact our sales team for pricing and technical support:\u003c\/p\u003e\n\u003cp\u003eEmail: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e (WhatsApp available)\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45296149659809,"sku":"DO810","price":138.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/DO810-1.jpg?v=1761899770","url":"https:\/\/www.autonexcontrol.com\/pl\/products\/do810-digital-output-module-16-channel-abb","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}