{"product_id":"abb-ai880a-analog-input-module-sil3-safety-certified","title":"ABB AI880A Analog Input Module | SIL3 Safety Certified","description":"\u003ch2\u003eABB AI880A High Integrity Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e8b57;\"\u003eABB\u003c\/strong\u003e \u003cstrong style=\"color: #2e8b57;\"\u003eAI880A\u003c\/strong\u003e module provides eight safety-certified analog input channels for critical applications. It supports both single and redundant configurations with SIL3 certification. This high-integrity module ensures reliable performance in safety instrumented systems.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eSIL3 certified\u003c\/span\u003e according to IEC 61508\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eEight current input channels\u003c\/span\u003e for 0-20mA and 4-20mA signals\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eSingle or redundant configuration\u003c\/span\u003e support\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eHART pass-through communication\u003c\/span\u003e capability\u003c\/li\u003e\n\u003cli\u003eNAMUR NE43 recommendation compliance\u003c\/li\u003e\n\u003cli\u003eAdvanced on-board diagnostics and monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003eABB\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003eAI880A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle Number:\u003c\/strong\u003e 3BSE039293R1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Types:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e0-20mA, 4-20mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e12-bit\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 250 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003eMax. 0.1% error\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Cycle:\u003c\/strong\u003e 10 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Support:\u003c\/strong\u003e Yes, with pass-through\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Cable Length:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e600 meters\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eSIL3 certified\u003c\/span\u003e according to IEC 61508\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eCategory 4\u003c\/span\u003e according to EN 954-1\u003c\/li\u003e\n\u003cli\u003eNAMUR NE43 recommendation compliance\u003c\/li\u003e\n\u003cli\u003eHazardous location certifications\u003c\/li\u003e\n\u003cli\u003eMarine certifications: ABS, BV, DNV, LR\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransmitter Power \u0026amp; Isolation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eCurrent-limited transmitter supply\u003c\/span\u003e per channel\u003c\/li\u003e\n\u003cli\u003eSupports 2-wire and 3-wire transmitters\u003c\/li\u003e\n\u003cli\u003eGroup isolation from ground\u003c\/li\u003e\n\u003cli\u003eField power supervision and monitoring\u003c\/li\u003e\n\u003cli\u003eConfigurable alarm limits for field power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostics \u0026amp; Protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFront panel status LEDs (Fault, Run, Warning)\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e8b57;\"\u003eAdvanced on-board diagnostics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eInternal voltage supervision\u003c\/li\u003e\n\u003cli\u003eField power input and output monitoring\u003c\/li\u003e\n\u003cli\u003eConfigurable over\/under range limits\u003c\/li\u003e\n\u003cli\u003eNon-destructive max input voltage: 11V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eInput Filter:\u003c\/span\u003e 190 ms rise time (0-90%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eTemperature Drift:\u003c\/span\u003e Max. 50 ppm\/°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eNMRR:\u003c\/span\u003e \u0026gt;40 dB at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eOver Range:\u003c\/span\u003e +12% (0-20mA), +15% (4-20mA)\u003c\/li\u003e\n\u003cli\u003eLoop Supervised DI function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e+5V Modulebus:\u003c\/span\u003e 45 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e+24V Modulebus:\u003c\/span\u003e 50 mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e+24V External:\u003c\/span\u003e 4 mA + transmitter current, max 260 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003ePower Dissipation:\u003c\/span\u003e 2.4W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e8b57;\"\u003eOperating Temperature: 0 to +55°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40 to +70°C\u003c\/li\u003e\n\u003cli\u003eProtection Class: IP20\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5 to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003eCorrosive Atmosphere: ISA-S71.04 G3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Dimensions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 45 mm (1.77”)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 102 mm (4.01”)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 119 mm (4.7”)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.15 kg (0.33 lbs.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for S800 I\/O platform\u003c\/li\u003e\n\u003cli\u003eWorks with TU834, TU844, TU845 series\u003c\/li\u003e\n\u003cli\u003eCompatible with TU854 models\u003c\/li\u003e\n\u003cli\u003eKeying code: FD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSecure industrial packaging\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e8b57;\"\u003eWorldwide shipping via FedEx, UPS, DHL\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eComplete documentation included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat safety certifications does the AI880A have?\u003c\/h4\u003e\n\u003cp\u003eThe module is \u003cspan style=\"color: #2e8b57;\"\u003eSIL3 certified according to IEC 61508\u003c\/span\u003e and Category 4 according to EN 954-1.\u003c\/p\u003e\n\u003ch4\u003eDoes the module support HART communication?\u003c\/h4\u003e\n\u003cp\u003eYes, the \u003cspan style=\"color: #2e8b57;\"\u003eABB AI880A\u003c\/span\u003e features \u003cspan style=\"color: #2e8b57;\"\u003eHART pass-through communication\u003c\/span\u003e capability.\u003c\/p\u003e\n\u003ch4\u003eWhat is the module's resolution?\u003c\/h4\u003e\n\u003cp\u003eIt provides \u003cspan style=\"color: #2e8b57;\"\u003e12-bit resolution\u003c\/span\u003e for accurate current input measurements.\u003c\/p\u003e\n\u003ch4\u003eCan the module operate in redundant configuration?\u003c\/h4\u003e\n\u003cp\u003eYes, it supports both \u003cspan style=\"color: #2e8b57;\"\u003esingle and redundant operation\u003c\/span\u003e for high availability.\u003c\/p\u003e\n\u003ch4\u003eWhat standards does the module comply with?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #2e8b57;\"\u003eABB AI880A\u003c\/span\u003e complies with \u003cspan style=\"color: #2e8b57;\"\u003eNAMUR NE43\u003c\/span\u003e recommendations for signal ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eCopyright © 2025 AutoNex Controls Limited. All rights reserved.\u003c\/p\u003e\n\u003cp\u003eReference Source: \u003ca href=\"https:\/\/www.autonexcontrol.com\/\"\u003ewww.autonexcontrol.com\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eContact our sales team for pricing and technical support:\u003c\/p\u003e\n\u003cp\u003eEmail: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e (WhatsApp available)\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45296182231201,"sku":"AI880A","price":104.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/AI880A.jpg?v=1761904203","url":"https:\/\/www.autonexcontrol.com\/pl\/products\/abb-ai880a-analog-input-module-sil3-safety-certified","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}