{"product_id":"10302-1-1-plc-module-honeywell","title":"10302\/1\/1 PLC Module Honeywell","description":"\u003ch2\u003e\u003cstrong\u003e10302\/1\/1 Watchdog Repeater: Essential Power Monitoring Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eModule Overview \u0026amp; Core Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003ePrimary Function:\u003c\/strong\u003e The module \u003cstrong\u003emonitors 5 Vdc and 24 Vdc power supplies\u003c\/strong\u003e to connected I\/O modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eWatchdog Output:\u003c\/strong\u003e It provides a \u003cstrong\u003ewatchdog output signal\u003c\/strong\u003e to the watchdog inputs of monitored output modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eSystem Configuration:\u003c\/strong\u003e Essential in systems with \u003cstrong\u003emultiple power supply units (PSUs)\u003c\/strong\u003e or mixed redundant\/non-redundant I\/O parts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eInternational Approvals:\u003c\/strong\u003e The \u003cstrong\u003e10302\/1\/1\u003c\/strong\u003e carries \u003cstrong\u003eCE, TÜV, and UL\u003c\/strong\u003e certifications for global use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Electrical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eModule Power Consumption:\u003c\/strong\u003e Requires \u003cstrong\u003e5 Vdc at 35 mA\u003c\/strong\u003e and \u003cstrong\u003e24 Vdc at 25 mA\u003c\/strong\u003e for operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eWatchdog Input:\u003c\/strong\u003e The WDG1 and WDG2 inputs each draw \u003cstrong\u003e0.1 mA monitoring current\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eOutput Capacity:\u003c\/strong\u003e The WDR OUT provides \u003cstrong\u003emaximum output current of 900 mA\u003c\/strong\u003e to drive watchdog circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eVoltage Monitoring:\u003c\/strong\u003e Specifically designed to monitor \u003cstrong\u003estandard 5V and 24V DC I\/O power rails\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical Design \u0026amp; Key Coding\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eMounting Size:\u003c\/strong\u003e Compact design requires \u003cstrong\u003e4 TE, 3 HE (4 HP, 3U)\u003c\/strong\u003e of rack space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eModule Key Code:\u003c\/strong\u003e Configured with \u003cstrong\u003eholes at position A27\u003c\/strong\u003e and \u003cstrong\u003epins at C11, C23, C27\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eRack Key Code:\u003c\/strong\u003e Corresponding rack requires \u003cstrong\u003eblind spots at C3, C19, C31\u003c\/strong\u003e and \u003cstrong\u003elarge pins at A27\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eBus Connection:\u003c\/strong\u003e Requires \u003cstrong\u003ehorizontal bus connection\u003c\/strong\u003e in standard I\/O rack positions 1 through 18.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10302\/1\/1 module actually monitor?\u003c\/strong\u003e\u003cbr\u003eIt continuously monitors the \u003cstrong\u003e5 Vdc and 24 Vdc power supplies\u003c\/strong\u003e that power your system's I\/O modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen is this watchdog repeater required?\u003c\/strong\u003e\u003cbr\u003eIt's essential in systems with \u003cstrong\u003emultiple PSUs, specific power supply types, or redundant I\/O sections\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum output current capability?\u003c\/strong\u003e\u003cbr\u003eThe watchdog output can supply \u003cstrong\u003eup to 900 mA\u003c\/strong\u003e to connected modules' watchdog inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I replace the module while the system is running?\u003c\/strong\u003e\u003cbr\u003eYes, it's \u003cstrong\u003ehot-swappable\u003c\/strong\u003e, but may trigger a \u003cstrong\u003eCentral Part shutdown\u003c\/strong\u003e during exchange.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your shipping and return policy?\u003c\/strong\u003e\u003cbr\u003eWe \u003cstrong\u003eship within 5 days\u003c\/strong\u003e via major carriers and offer a \u003cstrong\u003e30-day return policy\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information \u0026amp; Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45576327430305,"sku":"10302\/1\/1","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/10302_1_1.jpg?v=1766654289","url":"https:\/\/www.autonexcontrol.com\/pl\/products\/10302-1-1-plc-module-honeywell","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}