{"product_id":"transducer-190501-07-00-01-bently-nevada","title":"Transducer 190501-07-00-01 Bently Nevada","description":"\u003ch2\u003eBently Nevada 190501 Velomitor CT Velocity Transducer Overview\u003c\/h2\u003e\n\u003ch3\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e190501-07-00-01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Velomitor CT Velocity Transducer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e3.94 mV\/mm\/s ±5%\u003c\/span\u003e consistent output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e3.0 Hz to 900 Hz ±1.0 dB\u003c\/span\u003e range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Certifications:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003eCSA, ATEX, IECEx\u003c\/span\u003e approved\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZone Classification:\u003c\/strong\u003e Certified for \u003cspan style=\"color: #2e86ab;\"\u003eClass I, Zone 0\/1\u003c\/span\u003e areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Hardware:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003ePlate stud 3\/8-in-24 to 3\/8-in-24\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e-40°C to +85°C\u003c\/span\u003e full range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e0.297 kg\u003c\/span\u003e compact design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHazardous Area Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA\/NRTL\/C:\u003c\/strong\u003e Certified for \u003cspan style=\"color: #2e86ab;\"\u003eClass I, Division 1\u003c\/span\u003e areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx\/CSA:\u003c\/strong\u003e Approved for \u003cspan style=\"color: #2e86ab;\"\u003eClass I, Zone 0\/1\u003c\/span\u003e locations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsic Safety:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003eEx ia IIC T4\u003c\/span\u003e protection concept\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Groups:\u003c\/strong\u003e Suitable for \u003cspan style=\"color: #2e86ab;\"\u003eGroups A, B, C, D\u003c\/span\u003e atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDust Environments:\u003c\/strong\u003e Certified for \u003cspan style=\"color: #2e86ab;\"\u003eClass II \u0026amp; III\u003c\/span\u003e areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Follow \u003cspan style=\"color: #2e86ab;\"\u003edrawing 167536\u003c\/span\u003e for compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMounting \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003ePlate stud 3\/8-in-24 to 3\/8-in-24\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Torque:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e4.5 N·m ±0.6 N·m\u003c\/span\u003e required setting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Surface:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e33 mm diameter\u003c\/span\u003e minimum area\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase Material:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e316L stainless steel\u003c\/span\u003e construction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Interface:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003eMIL-C-5015\u003c\/span\u003e connector type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation:\u003c\/strong\u003e Functions in \u003cspan style=\"color: #2e86ab;\"\u003eany mounting angle\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Bias Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e10.1 Vdc ±1.0 Vdc\u003c\/span\u003e reference\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Output Impedance:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e\u0026lt;400 Ω typical\u003c\/span\u003e low impedance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmplitude Linearity:\u003c\/strong\u003e Maintains \u003cspan style=\"color: #2e86ab;\"\u003e±2% to 63.5 mm\/s pk\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransverse Sensitivity:\u003c\/strong\u003e Less than \u003cspan style=\"color: #2e86ab;\"\u003e5% of axial response\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounted Resonance:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e9 kHz minimum\u003c\/span\u003e frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e Supports \u003cspan style=\"color: #2e86ab;\"\u003e305 metre cables\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Durability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Operation:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e-40°C to +85°C\u003c\/span\u003e operating range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e-40°C to +100°C\u003c\/span\u003e capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e Withstands \u003cspan style=\"color: #2e86ab;\"\u003e5000 g pk shock\u003c\/span\u003e levels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Tolerance:\u003c\/strong\u003e Handles \u003cspan style=\"color: #2e86ab;\"\u003e100% condensing\u003c\/span\u003e moisture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic Immunity:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e\u0026lt;0.0068 mm\/s\/gauss\u003c\/span\u003e susceptibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003eInternal electronics isolated from case\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What hazardous area certifications does this model have?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The \u003cstrong\u003e190501-07-00-01\u003c\/strong\u003e carries \u003cspan style=\"color: #2e86ab;\"\u003eCSA, ATEX, and IECEx certifications\u003c\/span\u003e for Class I, Zone 0\/1 and Division 1 areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the difference between Zone 0 and Zone 1 certification?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Zone 0 indicates \u003cspan style=\"color: #2e86ab;\"\u003econtinuous hazardous atmosphere\u003c\/span\u003e, while Zone 1 indicates \u003cspan style=\"color: #2e86ab;\"\u003eoccasional presence\u003c\/span\u003e of explosive gases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What mounting hardware is included?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e This model includes a \u003cspan style=\"color: #2e86ab;\"\u003eplate stud adapter maintaining 3\/8-in-24 threading\u003c\/span\u003e on both sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can this sensor be used in North American facilities?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, the \u003cspan style=\"color: #2e86ab;\"\u003eCSA certification\u003c\/span\u003e makes it suitable for use in both Canadian and US hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the temperature code rating?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e This sensor carries a \u003cspan style=\"color: #2e86ab;\"\u003eT4 temperature code\u003c\/span\u003e, suitable for gases with ignition temperatures above 135°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Are special installation procedures required?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, you must follow \u003cspan style=\"color: #2e86ab;\"\u003edrawing 167536\u003c\/span\u003e and applicable electrical codes for hazardous area installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor complete certification details and installation requirements in hazardous areas, download the full documentation.\u003cbr\u003e\u003cstrong\u003eAccess hazardous area certification package here: \u003ca href=\"https:\/\/ctrlnexus-auto.com\/wp-content\/uploads\/2025\/07\/190501-Datasheet.pdf\"\u003e190501-Datasheet.pdf\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor hazardous area applications and certification verification, contact our certified technical team.\u003cbr\u003e\u003cstrong\u003eContact: \u003cu\u003e\u003cspan style=\"color: #2e86ab;\"\u003esales@nex-auto.com\u003c\/span\u003e\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45399490625697,"sku":"190501-07-00-01","price":239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/190501-07-00-01.jpg?v=1763692808","url":"https:\/\/www.autonexcontrol.com\/it\/products\/transducer-190501-07-00-01-bently-nevada","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}