{"product_id":"is220ptcch1b-ge-thermocouple-input-module-mark-vie-i-o-pack","title":"IS220PTCCH1B GE Thermocouple Input Module | Mark VIe I\/O Pack","description":"\u003ch2\u003e\u003cstrong\u003eIS220PTCCH1B – General Electric Mark VIe Thermocouple Input I\/O Pack\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e General Electric | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIS220PTCCH1B\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark VIe Speedtronic | \u003cstrong\u003eFunction:\u003c\/strong\u003e Thermocouple Input I\/O Pack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e 12 combustion optimized inputs plus 1 cold junction reference\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e -8 to 45 mV for thermocouple and millivolt signals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple Types Supported:\u003c\/strong\u003e E, J, K, S, T (grounded or ungrounded)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 28 V dc at 0.16 Amp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e Simplex, duplex, and triple modular redundancy (TMR) configurations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cable Distance:\u003c\/strong\u003e 984 feet (300 meters) from turbine I\/O panel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cable Resistance:\u003c\/strong\u003e 450 ohms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eThermocouple Input Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIS220PTCCH1B\u003c\/strong\u003e accepts standard thermocouple types E, J, K, S, and T for versatile temperature measurement.\u003c\/li\u003e\n\u003cli\u003eThis module handles both grounded and ungrounded thermocouple configurations without signal degradation.\u003c\/li\u003e\n\u003cli\u003eEach of the 12 inputs provides combustion-optimized performance for gas turbine monitoring.\u003c\/li\u003e\n\u003cli\u003eThe onboard cold junction reference ensures accurate temperature compensation across all channels.\u003c\/li\u003e\n\u003cli\u003emV inputs from -8 to 45 mV allow direct connection of millivolt-generating sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Integration \u0026amp; Redundancy Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIS220PTCCH1B\u003c\/strong\u003e supports simplex configuration for standard single-channel applications.\u003c\/li\u003e\n\u003cli\u003eDuplex configuration provides dual-channel redundancy for enhanced system availability.\u003c\/li\u003e\n\u003cli\u003eTriple modular redundancy (TMR) offers the highest level of fault tolerance for critical turbine control.\u003c\/li\u003e\n\u003cli\u003eThis I\/O Pack integrates seamlessly with Mark VIe Speedtronic gas turbine control systems.\u003c\/li\u003e\n\u003cli\u003eInstall the module up to 984 feet from the turbine I\/O panel for flexible system layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain cable resistance below 450 ohms to ensure accurate signal transmission.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielded thermocouple extension wire for E, J, K, S, or T type sensors.\u003c\/li\u003e\n\u003cli\u003eRoute thermocouple wiring away from high-voltage power cables to minimize noise interference.\u003c\/li\u003e\n\u003cli\u003eConnect grounded or ungrounded thermocouples directly to the 12 input channels.\u003c\/li\u003e\n\u003cli\u003eThe cold junction sensor requires proper placement for accurate reference temperature measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOperating Environment \u0026amp; Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral Electric designed the \u003cstrong\u003eIS220PTCCH1B\u003c\/strong\u003e for harsh industrial gas turbine environments.\u003c\/li\u003e\n\u003cli\u003eThis I\/O Pack delivers consistent performance under demanding temperature conditions.\u003c\/li\u003e\n\u003cli\u003eSurface mount technology provides reliable signal processing for critical turbine measurements.\u003c\/li\u003e\n\u003cli\u003eThe module undergoes rigorous testing to meet GE Speedtronic quality standards.\u003c\/li\u003e\n\u003cli\u003ePart of the Mark VIe series, this board integrates with other GE control system components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the IS220PTCCH1B a brand new original product?\u003c\/strong\u003e\u003cbr\u003eYes, we supply \u003cstrong\u003eIS220PTCCH1B\u003c\/strong\u003e as a brand new original unit, factory-sealed and ready for installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have this model in stock?\u003c\/strong\u003e\u003cbr\u003eYes, we keep \u003cstrong\u003eIS220PTCCH1B\u003c\/strong\u003e in stock for immediate orders. Inventory is regularly updated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the typical lead time for shipping?\u003c\/strong\u003e\u003cbr\u003eWe process and ship orders within 5 business days after payment confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich carriers do you use for delivery?\u003c\/strong\u003e\u003cbr\u003eWe ship via FedEx, UPS, and DHL to ensure fast and reliable global delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your return policy?\u003c\/strong\u003e\u003cbr\u003eWe support 30-day returns. If you are not satisfied, contact us within 30 days for return instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat thermocouple types does this module support?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eIS220PTCCH1B\u003c\/strong\u003e supports E, J, K, S, and T thermocouples in grounded or ungrounded configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum cable distance for thermocouples?\u003c\/strong\u003e\u003cbr\u003eYou can place thermocouples up to 984 feet from the turbine I\/O panel with cable resistance below 450 ohms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this module in a redundant system?\u003c\/strong\u003e\u003cbr\u003eYes, the \u003cstrong\u003eIS220PTCCH1B\u003c\/strong\u003e supports simplex, duplex, and triple modular redundancy (TMR) configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the input voltage range?\u003c\/strong\u003e\u003cbr\u003eThe module accepts millivolt inputs from -8 to 45 mV for thermocouple and sensor signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner NexAuto Technology Limited:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45843142836385,"sku":"IS220PTCCH1B","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IS220PTCCH1B.jpg?v=1774249646","url":"https:\/\/www.autonexcontrol.com\/it\/products\/is220ptcch1b-ge-thermocouple-input-module-mark-vie-i-o-pack","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}