{"product_id":"is200epctg1a-ge-fanuc-exciter-pt-ct-board-ex2100-series","title":"IS200EPCTG1A GE Fanuc Exciter PT\/CT Board EX2100 Series","description":"\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\u003cmeta name=\"description\" content=\"IS200EPCTG1A GE PT\/CT board for EX2100 series. Handles 115V PT \u0026amp; 1A\/5A CT inputs with isolation transformers. -30 to 65°C operation. In stock.\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eIS200EPCTG1A Exciter PT\/CT Terminal Board – Precision Signal Conditioning for EX2100\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: \u003cstrong\u003eGeneral Electric\u003c\/strong\u003e — part of the \u003cstrong\u003eEX2100 series\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFunction: Exciter PT\/CT Terminal Board (\u003cstrong\u003eEPCT\u003c\/strong\u003e) for generator voltage and current feedback.\u003c\/li\u003e\n\u003cli\u003eInput types: Two 3-phase PT inputs (115 V rms, 50\/60 Hz) and two CT inputs (1 A or 5 A).\u003c\/li\u003e\n\u003cli\u003eIsolation: Onboard isolation transformers provide critical signal separation.\u003c\/li\u003e\n\u003cli\u003eAnalog input: One non-isolated channel accepts 0–10 V dc or 4–20 mA (selectable via JP1).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIS200EPCTG1A\u003c\/strong\u003e — GE part number for the \u003cstrong\u003eEPCT\u003c\/strong\u003e board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 28 V dc (supplied from the control rack).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePT input rating:\u003c\/strong\u003e 115 V rms ± , with internal fuses; burden \u003cspan style=\"color: #2563eb;\"\u003eless than 1 VA\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT input range:\u003c\/strong\u003e 1 A or 5 A ac; burden \u003cspan style=\"color: #2563eb;\"\u003eless than 1 VA\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScaled outputs:\u003c\/strong\u003e Isolation transformers produce 1.533 V rms for 115 V PT input (open delta).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog input range:\u003c\/strong\u003e 0–10 V dc or 4–20 mA; cable resistance ≤15 Ω for 300 m max length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -30 to 65 °C — suitable for harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions \u0026amp; weight:\u003c\/strong\u003e 23.8 cm x 8.6 cm; 0.45 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Accepts #10 AWG to #12 AWG; PT\/CT cables up to 1000 ft.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBoard Layout and Connectivity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree terminal blocks: \u003cstrong\u003eTB1\u003c\/strong\u003e for PT\/CT field wiring; \u003cstrong\u003eTB2, TB3\u003c\/strong\u003e for CT shorting protection.\u003c\/li\u003e\n\u003cli\u003eConnectors \u003cspan style=\"color: #2563eb;\"\u003eJ305, J308, J315\u003c\/span\u003e route signals to EMIO board in simplex or redundant controllers.\u003c\/li\u003e\n\u003cli\u003eEight test points (\u003cspan style=\"color: #2563eb;\"\u003eTP1–TP8\u003c\/span\u003e) allow direct monitoring of isolation transformer secondary legs.\u003c\/li\u003e\n\u003cli\u003eSwitch configuration on TB1 matches generator PT wiring (wye or delta).\u003c\/li\u003e\n\u003cli\u003eMaximum wire size #12 AWG for PT circuits ensures low voltage drop over 1000 ft.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Accuracy \u0026amp; Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGenerator voltage measurement uses two isolation transformers creating a three-wire open delta output.\u003c\/li\u003e\n\u003cli\u003eGenerator current measurement uses dedicated CT isolation transformers preserving signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2563eb;\"\u003eHigh reliability\u003c\/span\u003e designs allow up to three \u003cstrong\u003eIS200EPCTG1A\u003c\/strong\u003e boards in parallel for redundant systems.\u003c\/li\u003e\n\u003cli\u003eBuilt-in burden \u0026lt;1 VA minimizes loading on PTs and CTs.\u003c\/li\u003e\n\u003cli\u003eAnalog input provides 0.1% resolution for 4–20 mA or 0–10 V signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the function of the \u003cstrong\u003eIS200EPCTG1A\u003c\/strong\u003e?\u003c\/strong\u003e It conditions PT and CT feedback signals from generators providing isolated and scaled outputs to the EX2100 control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat PT voltages and CT currents can this board handle?\u003c\/strong\u003e It accepts 115 V rms PT inputs at 50\/60 Hz and CT inputs of 1 A or 5 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the \u003cstrong\u003eIS200EPCTG1A\u003c\/strong\u003e a new original part?\u003c\/strong\u003e Yes we supply brand new original sealed units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the shipping options and delivery time?\u003c\/strong\u003e We ship via FedEx UPS or DHL within 5 days of order with express courier taking 2–5 business days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return the board if unused?\u003c\/strong\u003e Yes we support 30-day returns for unopened items in original packaging.\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003cbr\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003eNexAuto Technology Limited – Official Site\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45802905698465,"sku":"IS200EPCTG1A","price":224.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IS200EPCTG1A.jpg?v=1776760701","url":"https:\/\/www.autonexcontrol.com\/it\/products\/is200epctg1a-ge-fanuc-exciter-pt-ct-board-ex2100-series","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}