{"product_id":"anb10d-425-cu2n-esb-bus-node-unit-yokogawa-dual-redundant","title":"ANB10D-425\/CU2N ESB Bus Node Unit | Yokogawa Dual-Redundant","description":"\u003ch2\u003e\u003cstrong\u003eYokogawa ANB10D-425\/CU2N ESB Bus Node Unit Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eYokogawa ANB10D-425\/CU2N\u003c\/strong\u003e ESB bus node unit provides reliable performance for industrial control systems. This node unit supports dual-redundant ESB bus communication and features dual-redundant power supply configuration. The unit operates with 220-240V AC power and mounts in standard 19-inch racks, making it ideal for various automation applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Yokogawa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003eANB10D-425\/CU2N\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e ESB Bus Node Unit for Dual-Redundant Bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Dual-redundant 220-240V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternative Power:\u003c\/strong\u003e Also supports 100-120V AC and 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 230 VA, 120 W (220-240V AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 10 kg including 8 I\/O modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Standard 19-inch rack mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion Protection:\u003c\/strong\u003e Basic type with no explosion protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Unit:\u003c\/strong\u003e Includes CU2N connector for ESB Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Connection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the unit in a 19-inch rack using M5 x 4 screws\u003c\/li\u003e\n\u003cli\u003eUse the provided insulation bush for electrical safety\u003c\/li\u003e\n\u003cli\u003eConnect dual-redundant power supply to ensure system reliability\u003c\/li\u003e\n\u003cli\u003eInstall up to 8 I\/O modules as needed for your application\u003c\/li\u003e\n\u003cli\u003eUse the CU2N connector unit for ESB bus connections\u003c\/li\u003e\n\u003cli\u003eEnsure proper cable management and ventilation space\u003c\/li\u003e\n\u003cli\u003eVerify all connections before applying power to the system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong style=\"color: #2e86ab;\"\u003eYokogawa ANB10D-425\/CU2N\u003c\/strong\u003e ESB bus node unit\u003c\/li\u003e\n\u003cli\u003eCU2N connector unit for ESB bus connections\u003c\/li\u003e\n\u003cli\u003eM5 x 4 screws for rack mounting\u003c\/li\u003e\n\u003cli\u003eInsulation bush accessories for safe installation\u003c\/li\u003e\n\u003cli\u003eRequired documentation and installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInternational shipping via FedEx, UPS, and DHL carriers\u003c\/li\u003e\n\u003cli\u003eOrder processing typically completes within 1-2 business days\u003c\/li\u003e\n\u003cli\u003eFull tracking information provided after shipment\u003c\/li\u003e\n\u003cli\u003eProfessional packaging ensures product safety during transit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does dual-redundant power supply mean?\u003c\/strong\u003e\u003cbr\u003eThe unit has two independent power inputs that provide backup if one fails, ensuring continuous operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many I\/O modules can this node unit support?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eANB10D-425\/CU2N\u003c\/strong\u003e can accommodate up to 8 I\/O modules simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat rack mounting hardware is required?\u003c\/strong\u003e\u003cbr\u003eUse M5 x 4 screws with the included insulation bush for secure rack installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this unit operate with different power voltages?\u003c\/strong\u003e\u003cbr\u003eYes, it supports 100-120V AC, 220-240V AC, and 24V DC power inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the purpose of the CU2N connector unit?\u003c\/strong\u003e\u003cbr\u003eThe CU2N provides specialized connections for the dual-redundant ESB bus communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor pricing information, technical specifications, or application support:\u003cbr\u003eEmail: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e (WhatsApp available)\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45428129628321,"sku":"ANB10D-425\/CU2N","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/ANB10D-410NDEL_3.jpg?v=1764139391","url":"https:\/\/www.autonexcontrol.com\/it\/products\/anb10d-425-cu2n-esb-bus-node-unit-yokogawa-dual-redundant","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}