{"product_id":"allen-bradley-1762-iq16-input-module","title":"Allen-Bradley - 1762-IQ16 Input Module","description":"\u003ch2\u003e\u003cstrong\u003eAllen-Bradley 1762-IQ16 16-Channel DC Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Allen-Bradley \u003cstrong\u003e\u003cspan style=\"color: #e74c3c;\"\u003e1762-IQ16\u003c\/span\u003e\u003c\/strong\u003e discrete input module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e 16-channel sink and source input module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Configuration:\u003c\/strong\u003e Sixteen discrete input channels with two commons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e24 Volts DC input power\u003c\/span\u003e required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Range:\u003c\/strong\u003e Works from \u003cspan style=\"color: #e74c3c;\"\u003e10 to 30 Volts DC\u003c\/span\u003e (10-26.4V DC continuous)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Response:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e8.0 millisecond\u003c\/span\u003e delay for both ON and OFF transitions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e2.0 mA min @ 10V, 8.0 mA nom @ 24V, 12.0 mA max @ 30V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Parameters:\u003c\/strong\u003e Maximum \u003cspan style=\"color: #e74c3c;\"\u003e5V DC voltage\u003c\/span\u003e and \u003cspan style=\"color: #e74c3c;\"\u003e1.5 mA current\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e Maximum \u003cspan style=\"color: #e74c3c;\"\u003e3.7 Watts\u003c\/span\u003e under normal operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Compatibility:\u003c\/strong\u003e Compatible with \u003cspan style=\"color: #e74c3c;\"\u003eMicroLogix 1100, 1200, and 1400\u003c\/span\u003e PLCs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion Capacity:\u003c\/strong\u003e Supports up to \u003cspan style=\"color: #e74c3c;\"\u003e4 modules with ML1100, 6 with ML1200, 7 with ML1400\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed Configurations:\u003c\/strong\u003e Can combine with other MicroLogix expansion modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Representation:\u003c\/strong\u003e Inputs use \u003cspan style=\"color: #e74c3c;\"\u003ebit positions 0 to 15 of word 0\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Formats:\u003c\/strong\u003e Supports \u003cspan style=\"color: #e74c3c;\"\u003ebinary, octal, decimal, and hexadecimal\u003c\/span\u003e representations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Required:\u003c\/strong\u003e Each channel requires \u003cspan style=\"color: #e74c3c;\"\u003eindividual configuration\u003c\/span\u003e after installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical \u0026amp; Physical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Options:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003eDIN rail mounting or direct panel mounting\u003c\/span\u003e available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Compact size: \u003cspan style=\"color: #e74c3c;\"\u003e90 x 87 x 40 mm (3.54 x 3.43 x 1.59 in)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003eIP20 rating\u003c\/span\u003e for basic environmental protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Interface:\u003c\/strong\u003e Communicates via \u003cspan style=\"color: #e74c3c;\"\u003e10-30V DC power\u003c\/span\u003e through 1762 bus interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Method:\u003c\/strong\u003e Uses \u003cspan style=\"color: #e74c3c;\"\u003eprovided ribbon cable\u003c\/span\u003e for module interconnection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Protection:\u003c\/strong\u003e Includes \u003cspan style=\"color: #e74c3c;\"\u003efinger-safe terminal covers\u003c\/span\u003e for safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSinking \u0026amp; Sourcing Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Capability:\u003c\/strong\u003e Supports both \u003cspan style=\"color: #e74c3c;\"\u003esinking and sourcing\u003c\/span\u003e field devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSinking Devices:\u003c\/strong\u003e Connect to \u003cspan style=\"color: #e74c3c;\"\u003enegative side\u003c\/span\u003e of the module terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSourcing Devices:\u003c\/strong\u003e Connect to \u003cspan style=\"color: #e74c3c;\"\u003epositive side\u003c\/span\u003e of the module terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Flow:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003eSourcing devices provide current\u003c\/span\u003e to sinking devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Regulation:\u003c\/strong\u003e Module regulates \u003cspan style=\"color: #e74c3c;\"\u003ecurrent flow between input and connected devices\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication \u0026amp; Device Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Device Support:\u003c\/strong\u003e Interfaces with \u003cspan style=\"color: #e74c3c;\"\u003elimit switches, proximity sensors, relay contacts\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Devices:\u003c\/strong\u003e Compatible with \u003cspan style=\"color: #e74c3c;\"\u003emagnetic contactors and other discrete devices\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Functionality:\u003c\/strong\u003e Expands \u003cspan style=\"color: #e74c3c;\"\u003eMicroLogix controller I\/O capabilities\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Efficiency:\u003c\/strong\u003e Requires \u003cspan style=\"color: #e74c3c;\"\u003eminimal installation space\u003c\/span\u003e for compact designs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Monitoring:\u003c\/strong\u003e Features \u003cspan style=\"color: #e74c3c;\"\u003esingle LED indicator\u003c\/span\u003e for power and diagnostic status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat controllers work with the 1762-IQ16 module?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003e1762-IQ16\u003c\/strong\u003e works with \u003cspan style=\"color: #e74c3c;\"\u003eMicroLogix 1100, 1200, and 1400\u003c\/span\u003e programmable controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many input channels does this module provide?\u003c\/strong\u003e\u003cbr\u003eThis module provides \u003cspan style=\"color: #e74c3c;\"\u003esixteen discrete input channels\u003c\/span\u003e for digital signal acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the response time for input signals?\u003c\/strong\u003e\u003cbr\u003eEach input channel has a \u003cspan style=\"color: #e74c3c;\"\u003e8.0 millisecond response time\u003c\/span\u003e for state changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this module handle both sinking and sourcing devices?\u003c\/strong\u003e\u003cbr\u003eYes, the \u003cstrong\u003e1762-IQ16\u003c\/strong\u003e supports \u003cspan style=\"color: #e74c3c;\"\u003eboth sinking and sourcing field devices\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating voltage range?\u003c\/strong\u003e\u003cbr\u003eThe module operates from \u003cspan style=\"color: #e74c3c;\"\u003e10 to 30 Volts DC\u003c\/span\u003e (10-26.4V DC continuous operation).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this module in stock for immediate delivery?\u003c\/strong\u003e\u003cbr\u003eYes, the \u003cstrong\u003e1762-IQ16\u003c\/strong\u003e is \u003cspan style=\"color: #e74c3c;\"\u003eavailable from stock\u003c\/span\u003e for quick worldwide shipping.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45541015748769,"sku":"1762-IQ16","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/1762-IQ16.jpg?v=1765782531","url":"https:\/\/www.autonexcontrol.com\/it\/products\/allen-bradley-1762-iq16-input-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}