{"product_id":"1747-m13-allen-bradley-slc-500-memory-module-64kb","title":"1747-M13 Allen-Bradley SLC 500 Memory Module 64KB","description":"\u003ch2\u003e\u003cstrong\u003e1747-M13 Allen-Bradley SLC 500 Memory Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e1747-M13\u003c\/strong\u003e Memory Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Type:\u003c\/strong\u003e Flash (non-volatile)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Size:\u003c\/strong\u003e 64 kilobytes \/ 64,000 user words\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Processors:\u003c\/strong\u003e SLC 5\/03, SLC 5\/04, SLC 5\/05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired Adapter:\u003c\/strong\u003e \u003cstrong\u003e1747-M15 Series B\u003c\/strong\u003e (do not use Series A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Program and data table storage backup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgram Scan Time:\u003c\/strong\u003e 0.9 milliseconds (when used with compatible processor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Scan Time:\u003c\/strong\u003e 0.225 milliseconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Chassis Support:\u003c\/strong\u003e Up to 3 chassis with 30 slots\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Method:\u003c\/strong\u003e Hardware PROM programmer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Location:\u003c\/strong\u003e Processor PC board (jumper configurable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Setting:\u003c\/strong\u003e Connect A18 to center pin for proper operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeyed Connectors:\u003c\/strong\u003e Yes, prevents improper installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the 1747-M13 new and original?\u003c\/strong\u003e\u003cbr\u003eYes, we supply only new original \u003cstrong\u003e1747-M13\u003c\/strong\u003e units directly from authorized stock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich processors work with the 1747-M13?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003e1747-M13\u003c\/strong\u003e works with SLC 5\/03, SLC 5\/04, and SLC 5\/05 processors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo I need a memory adapter for the 1747-M13?\u003c\/strong\u003e\u003cbr\u003eYes, you must use a \u003cstrong\u003e1747-M15 Series B\u003c\/strong\u003e memory adapter. Do not use Series A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat happens if I use a Series A adapter?\u003c\/strong\u003e\u003cbr\u003eA Series A \u003cstrong\u003e1747-M15\u003c\/strong\u003e may damage the \u003cstrong\u003e1747-M13\u003c\/strong\u003e memory module or the PROM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow does the 1747-M13 protect my program?\u003c\/strong\u003e\u003cbr\u003eFlash memory retains your program even when the processor battery dies. The processor loads the program automatically after each power cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have the 1747-M13 in stock?\u003c\/strong\u003e\u003cbr\u003eYes, we have the \u003cstrong\u003e1747-M13\u003c\/strong\u003e in stock and ready to ship.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your shipping and return policy?\u003c\/strong\u003e\u003cbr\u003eWe ship within 5 business days via DHL, FedEx, or UPS. You can return items within 30 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I install the 1747-M13 jumper?\u003c\/strong\u003e\u003cbr\u003eConnect the A18 pin to the center pin on the processor board for proper orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan electrostatic discharge damage this module?\u003c\/strong\u003e\u003cbr\u003eYes, ESD can alter or destroy the memory on the \u003cstrong\u003e1747-M13\u003c\/strong\u003e. Handle it carefully.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the processor load the program automatically?\u003c\/strong\u003e\u003cbr\u003eYes, the SLC 500 processor loads the program from the \u003cstrong\u003e1747-M13\u003c\/strong\u003e automatically at each power-up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner NexAuto Technology Limited:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45892677402785,"sku":"1747-M13","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/1747-M13.jpg?v=1775533842","url":"https:\/\/www.autonexcontrol.com\/it\/products\/1747-m13-allen-bradley-slc-500-memory-module-64kb","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}