{"product_id":"schneider-electric-140dio33000-intrinsically-safe-output-module","title":"Schneider Electric 140DIO33000 Intrinsically Safe Output Module","description":"\u003ch2\u003e\u003cstrong\u003eSchneider Electric Modicon Quantum Intrinsically Safe Output Module \u003cstrong\u003e140DIO33000\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \u0026amp; Series:\u003c\/strong\u003e \u003cstrong\u003e140DIO33000\u003c\/strong\u003e, part of the Modicon Quantum automation platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003eIntrinsically safe discrete output module\u003c\/strong\u003e\u003c\/span\u003e with open collector configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e Fixed at \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e24V DC\u003c\/strong\u003e\u003c\/span\u003e for IS applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e Provides up to \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e45mA per point\u003c\/strong\u003e\u003c\/span\u003e, with a maximum of 360mA for the entire module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current:\u003c\/strong\u003e Very low off-state leakage current of 0.4mA per point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Features \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003einternal fusing and transient voltage suppression\u003c\/strong\u003e\u003c\/span\u003e for circuit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Fast and consistent \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e1ms switching time\u003c\/strong\u003e\u003c\/span\u003e for both ON and OFF states with resistive loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e Limited to a safe \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e5 Watts\u003c\/strong\u003e\u003c\/span\u003e total.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications \u0026amp; Safety Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsic Safety Certifications:\u003c\/strong\u003e Certified for \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003eII 1 G\/D EEx ia IIC\u003c\/strong\u003e\u003c\/span\u003e and FM Class 1 Division 2 hazardous areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey Standards:\u003c\/strong\u003e Complies with ATEX 94\/9\/EC, EN 50014, EN 50020, UL 508, and CSA C22.2 No 142.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e High \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e2500V DC isolation between channels and the system bus\u003c\/strong\u003e\u003c\/span\u003e for safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Robustness:\u003c\/strong\u003e Resists electrostatic discharge (4kV contact) and electromagnetic fields.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental \u0026amp; Operational Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Stable performance from \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e0 to 60°C (32 to 140°F)\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e Can be stored in conditions from -40 to 85°C (-40 to 185°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity \u0026amp; Altitude:\u003c\/strong\u003e Rated for 95% non-condensing humidity and operation up to 5000 meters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Compatibility:\u003c\/strong\u003e Works with Unity Pro, Concept V2.2+, and ProWORX programming software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Integration Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Current:\u003c\/strong\u003e Requires \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e2.2A from the backplane\u003c\/strong\u003e\u003c\/span\u003e for module operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Swapping:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003eNot permitted\u003c\/strong\u003e\u003c\/span\u003e as per intrinsic safety standards to maintain certification integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Destination:\u003c\/strong\u003e Must be used \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003ein conjunction with other certified IS apparatus\u003c\/strong\u003e\u003c\/span\u003e for Zone 20\/21\/22.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e Module weighs 0.45 kg (0.99 lb).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the \u003cstrong\u003e140DIO33000\u003c\/strong\u003e module new and available?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e100% new, genuine Schneider Electric\u003c\/strong\u003e\u003c\/span\u003e stock for immediate shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does \"intrinsically safe\" mean for this module?\u003c\/strong\u003e\u003cbr\u003eA: It means the \u003cstrong\u003e140DIO33000\u003c\/strong\u003e is designed to \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003eprevent ignition in hazardous atmospheres\u003c\/strong\u003e\u003c\/span\u003e by limiting the electrical energy available at its outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I hot-swap this module in a live rack?\u003c\/strong\u003e\u003cbr\u003eA: No. \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003eHot swapping is strictly not allowed\u003c\/strong\u003e\u003c\/span\u003e for this intrinsically safe module to comply with safety standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum load I can connect to one output?\u003c\/strong\u003e\u003cbr\u003eA: Each output point can safely drive a load up to \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e45mA at 24V DC\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We offer a \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e30-day return policy\u003c\/strong\u003e\u003c\/span\u003e for unused items in their original packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more technical details, certification documents, or to place an order, please contact us.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e Email: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone\/WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":45673885860001,"sku":"140DIO33000","price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/140DIO33000.jpg?v=1769506642","url":"https:\/\/www.autonexcontrol.com\/fr\/products\/schneider-electric-140dio33000-intrinsically-safe-output-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}