{"product_id":"honeywell-fs-tsai-1620m-safe-analog-input-fta","title":"Honeywell FS-TSAI-1620M Safe Analog Input FTA","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell FS-TSAI-1620M Safe Analog Input FTA\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFS-TSAI-1620M\u003c\/strong\u003e from Honeywell is a high-integrity Safe Analog Input Field Terminal Assembly. It provides critical process signal acquisition for safety instrumented systems. This FTA ensures accurate and reliable data transfer with built-in diagnostics. We will now detail its essential specifications and installation notes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eFS-TSAI-1620M\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eProduct Type:\u003c\/strong\u003e Safe Analog Input FTA (Field Terminal Assembly)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eSafety Integrity Level:\u003c\/strong\u003e Up to SIL 3 (IEC 61508\/61511)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eInput Channels:\u003c\/strong\u003e 16 channels, individually isolated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eSignal Type:\u003c\/strong\u003e 4-20mA (HART® compatible)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eInput Impedance:\u003c\/strong\u003e 250 Ω per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eMeasurement Accuracy:\u003c\/strong\u003e ±0.1% of span (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eUpdate Rate:\u003c\/strong\u003e 100 ms per channel (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eCommon Mode Rejection:\u003c\/strong\u003e \u0026gt;120 dB at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eDiagnostic Coverage:\u003c\/strong\u003e \u0026gt;99% (hardware fault detection)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e74b5;\"\u003eCertifications:\u003c\/strong\u003e ATEX, IECEx, SIL3, CE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in a suitable hazardous area enclosure as per certification.\u003c\/li\u003e\n\u003cli\u003eUse recommended cable types and follow specified torque for terminals.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the assembly and the mounting rail.\u003c\/li\u003e\n\u003cli\u003eConfigure channel parameters via the associated safety controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne (1) Honeywell \u003cstrong\u003eFS-TSAI-1620M\u003c\/strong\u003e FTA module.\u003c\/li\u003e\n\u003cli\u003eOne (1) installation guide and safety manual.\u003c\/li\u003e\n\u003cli\u003eShipped via FedEx, UPS, or DHL with tracking provided.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is a Safe Analog Input FTA?\u003c\/strong\u003e It is a certified module for reading analog signals in safety-critical applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs HART communication supported?\u003c\/strong\u003e Yes, the module supports HART signal pass-through on the 4-20mA lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the main application?\u003c\/strong\u003e Connecting transmitters in SIL-rated safety loops in process plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor safety manuals and application support for the Honeywell \u003cstrong\u003eFS-TSAI-1620M\u003c\/strong\u003e, contact our team.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact Us:\u003c\/strong\u003e\u003cbr\u003eEmail: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone\/WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45525596307617,"sku":"FS-TSAI-1620M","price":530.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/FS-TSAI-1620M_1.jpg?v=1765445954","url":"https:\/\/www.autonexcontrol.com\/fr\/products\/honeywell-fs-tsai-1620m-safe-analog-input-fta","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}