Passer aux informations sur le produit
1 sur 3

BMXSRA0405 Schneider Modicon X80 Safety Relay Output Module

En stock (15 unités), prêt à être expédié
  • Fournisseur :

    Schneider

  • Type :

    Output Module

  • Country of Origin:

    FR

  • Dimensions:

    5.5*18*26cm

  • Weight:

    115 g

  • Étiquettes : Bmxsra0405 Output module

BMXSRA0405 Schneider Modicon X80 Safety Relay Output Module

Key Technical Specifications

  • Brand & Model: Schneider Electric BMXSRA0405 belongs to the Modicon X80 product family.
  • Discrete Outputs: Provides 4 isolated relay outputs compliant with EN/IEC 61131-2 standards.
  • Output Voltage Range: Supports 24 to 240V AC (10 to 264V AC) and 12 to 24V DC (10 to 34V DC).
  • Conventional Free Air Thermal Current: Rated at 5 A per output channel.
  • Response Time: Delivers 12 ms activation time and 6 ms deactivation time.
  • Insulation Resistance: Provides >10 MOhm insulation resistance at 500V DC.
  • Power Dissipation & Consumption: Dissipates 3.9 W with typical consumption of 240 mA at 3.3V DC and 130 mA at 24V DC.
  • MTBF Reliability: Offers exceptional reliability with 624,000 hours MTBF.
  • Minimum Switching Current: Requires 10 mA minimum at 5V DC for reliable switching.
  • Maximum Switching Voltage: Supports up to 230V AC switching capability.
  • Mechanical Durability: Achieves 10,000,000 mechanical cycles for long service life.
  • Electrical Durability: Provides extensive cycle ratings for AC-15, AC-12, DC-13, and DC-12 load categories at various power levels.
  • Switching Frequency: Supports up to 50 Hz switching frequency.

Protection & External Component Requirements

  • External Short-Circuit Protection: Requires one fast-blow fuse per channel or per group of channels.
  • External Overload Protection: Use one fast-blow fuse per channel or per group of channels for overload protection.
  • Overvoltage Protection for AC Loads: Use RC circuit or ZNO surge limiter on each AC output.
  • Overvoltage Protection for DC Loads: Use discharge diode on each DC output for inductive load protection.
  • Recommended Fuse: Install appropriate fast-blow fuses based on connected load specifications.

Environmental & Mechanical Durability

  • Operating Temperature: Functions reliably from -25°C to 60°C (-13°F to 140°F).
  • Storage Temperature: Withstands -40°C to 85°C (-40°F to 185°F) for long-term storage.
  • Humidity & Coatings: Handles 5% to 95% relative humidity at 55°C without condensation and includes conformal coating protection.
  • Environmental Resistance: Rated for gas resistant class Gx, 3C4, dust resistant class 3S4, sand resistant class 3S4, salt resistant level 2, and mold growth resistant class 3B2.
  • Vibration & Shock: Resists 3 gn vibration and 15 gn shock for robust industrial use.
  • Operating Altitude: Supports 0 to 2000 meters normally, with derating up to 5000 meters.
  • Dielectric Strength: Provides 2000V AC for 1 minute between output circuits and ground.
  • IP Protection: Rated IP20 for protection in control cabinet environments.

Frequently Asked Questions (FAQ)

  • Is the BMXSRA0405 a new original module?
    Yes, we supply only brand new and original products directly from authorized sources.
  • Do you have this module in stock?
    Yes, we maintain available stock for the Schneider Electric BMXSRA0405. Orders process quickly.
  • What is the typical lead time for shipping?
    We ship within 5 days after order confirmation. Expedited options are available upon request.
  • Which carriers do you use for delivery?
    We commonly ship via FedEx, UPS, and DHL to ensure reliable and trackable delivery worldwide.
  • Can I return the module if it does not meet my needs?
    Yes, we support returns within 30 days of delivery. Please contact us for return authorization.
  • What voltage ranges does this relay output module support?
    The BMXSRA0405 supports 24 to 240V AC (10 to 264V AC) and 12 to 24V DC (10 to 34V DC).
  • What external protection does this module require?
    It requires fast-blow fuses per channel. For inductive loads, use discharge diodes for DC or RC circuits for AC.
  • What is the response time for relay outputs?
    The module provides 12 ms activation time and 6 ms deactivation tim
  • What is the maximum current per output channel?
    Each relay channel supports up to 5 A conventional free air thermal current.
  • Is this module suitable for switching inductive loads?
    Yes, with appropriate external protection components like discharge diodes or RC circuits.

For inquiries or to place an order, please contact us:

sales@nex-auto.com
+86 153 9242 9628

Partner NexAuto Technology Limited

Expédition rapide et fiable

Livraison rapide dans le monde entier

pour que vos projets d'automatisation respectent les délais.

Authentique et Fiable

Tous les composants sont 100 % authentiques

garantissant des performances fiables pour vos systèmes.

  • Livraison express
  • 12 mois de garantie
  • Retour facile sous 30 jours
Voir les détails du produit

Service client

Obtenez de l'aide quand vous en avez le plus besoin