{"product_id":"1734-apb-allen-bradley-profibus-dp-network-adapter","title":"1734-APB Allen-Bradley PROFIBUS DP Network Adapter","description":"\u003ch2\u003e\u003cstrong\u003eAllen-Bradley 1734-APB PROFIBUS DP Network Adapter Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003e1734-APB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Bulletin 1734 POINT I\/O Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e \u003cspan style=\"color: #0066cc;\"\u003ePROFIBUS DP Network Adapter\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage (Nominal):\u003c\/strong\u003e 24 Volts DC (range: 10 to 28.8V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Side Power:\u003c\/strong\u003e 400 milliamps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e 6 Amps maximum for 10 milliseconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 8 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePOINTBus Current:\u003c\/strong\u003e \u003cspan style=\"color: #0066cc;\"\u003e1000 milliamps (1 Amp max at 5V DC ±5%)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 2.8 Watts (at 28.8 Volts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Overvoltage Protection:\u003c\/strong\u003e Reverse Polarity Protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Hold-up Time:\u003c\/strong\u003e 10ms at 10V with maximum load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Power Maximum:\u003c\/strong\u003e 10 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical Current Draw per I\/O Module:\u003c\/strong\u003e 75mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum I\/O Modules Supported:\u003c\/strong\u003e 63 modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Compliance:\u003c\/strong\u003e SELV, NEC Class 2, or PELV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail (installed at left side of 1734 system)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have this item in stock?\u003c\/strong\u003e Yes, we have \u003cstrong\u003e1734-APB\u003c\/strong\u003e in stock and ready to ship.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the typical lead time?\u003c\/strong\u003e We ship within 5 days after you place the order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich carriers do you use?\u003c\/strong\u003e We commonly use DHL, FedEx, and UPS for reliable delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return this module?\u003c\/strong\u003e Yes, we support returns within 30 days from the delivery date.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many I\/O modules can this adapter support?\u003c\/strong\u003e It supports up to 63 POINT I\/O modules maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the PointBus output current?\u003c\/strong\u003e The PointBus output current is 1 Amp maximum at 5V DC ±5%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this adapter provide reverse polarity protection?\u003c\/strong\u003e Yes, it includes built-in reverse polarity protection for input overvoltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat power supply should I use?\u003c\/strong\u003e Use a SELV, NEC Class 2, or PELV power supply for CE compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this adapter power all connected I\/O modules?\u003c\/strong\u003e Yes, it converts field power to 5V logic power for up to 14 modules without external power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat happens during a brief power interruption?\u003c\/strong\u003e The output voltage stays within specifications for 10ms at 10V with maximum load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top: 20px;\"\u003eFor any inquiries, please contact us at \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or call \u003ca rel=\"noopener noreferrer\" href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e (WhatsApp).\u003c\/p\u003e\n\u003cp\u003ePartner: \u003ca rel=\"noopener noreferrer\" href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45952732004513,"sku":"1734-APB","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/1734-APB.jpg?v=1776850107","url":"https:\/\/www.autonexcontrol.com\/fr\/products\/1734-apb-allen-bradley-profibus-dp-network-adapter","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}