{"product_id":"pm863k01-ac-800m-high-integrity-controller-abb-3bse088381r1","title":"PM863K01 AC 800M High Integrity Controller | ABB 3BSE088381R1","description":"\u003ch2\u003e\u003cstrong\u003ePM863K01 AC 800M High Integrity Controller\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe PM863K01 from ABB provides high-performance processing with safety integrity capabilities for critical automation applications. This controller supports SIL 3 certification when combined with SM812 safety modules. It delivers both standard control and safety functionality in a single robust unit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eController Architecture and Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures \u003cspan style=\"color: #2c3e50;\"\u003eMPC866 microprocessor\u003c\/span\u003e with 96 MHz clock frequency\u003c\/li\u003e\n\u003cli\u003eContains 32 MB RAM with 22.184 MB available for applications\u003c\/li\u003e\n\u003cli\u003eIncludes real-time clock with lithium backup battery\u003c\/li\u003e\n\u003cli\u003eSupports high-integrity functionality with SM812 safety module\u003c\/li\u003e\n\u003cli\u003eCompactFlash interface for firmware storage and updates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e PM863K01 (Article 3BSE088381R1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor Type:\u003c\/strong\u003e MPC866 at 96 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Capacity:\u003c\/strong\u003e 32 MB RAM, 18 MB Flash PROM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerformance:\u003c\/strong\u003e 0.17 ms for 1000 boolean operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Cycle Time:\u003c\/strong\u003e 10 ms for application programs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 V DC (19.2-30 V DC range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 210 mA typical, 360 mA maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety and Certification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e74c3c;\"\u003eSIL 3 certified\u003c\/span\u003e when used with SM812 safety module\u003c\/li\u003e\n\u003cli\u003eTÜV approved for SIL 2 and SIL 3 safety applications\u003c\/li\u003e\n\u003cli\u003eISA Secure certified for cybersecurity protection\u003c\/li\u003e\n\u003cli\u003eIEC 61508 compliant safety environment\u003c\/li\u003e\n\u003cli\u003eRequires configuration according to Safety Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo \u003cspan style=\"color: #27ae60;\"\u003eRJ45 Ethernet ports\u003c\/span\u003e (CN1, CN2) for control network\u003c\/li\u003e\n\u003cli\u003eTwo RS-232C serial ports (COM3, COM4) for configuration\u003c\/li\u003e\n\u003cli\u003eSupports MMS and IAC protocols over Ethernet networks\u003c\/li\u003e\n\u003cli\u003e10 Mbit\/s Ethernet speed with RJ-45 connectors\u003c\/li\u003e\n\u003cli\u003eClock synchronization within 1 ms between controllers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Capacity and Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports up to 32 applications per controller\u003c\/li\u003e\n\u003cli\u003eHandles 64 programs and 128 diagrams per application\u003c\/li\u003e\n\u003cli\u003eManages 32 tasks with 32 different cycle times\u003c\/li\u003e\n\u003cli\u003eModulebus supports maximum 96 I\/O modules\u003c\/li\u003e\n\u003cli\u003eCEX-Bus supports up to 12 communication modules\u003c\/li\u003e\n\u003cli\u003eEvent queue capacity of 3000 events per OPC client\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHigh Integrity Functionality\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnables upgrade to SIL-certified control schemes\u003c\/li\u003e\n\u003cli\u003eSupports S800 I\/O High Integrity configurations\u003c\/li\u003e\n\u003cli\u003eCombines safety and process control in one unit\u003c\/li\u003e\n\u003cli\u003ePlug-in SM81x module for safety functionality\u003c\/li\u003e\n\u003cli\u003eCertified control environment without safety compromise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24 V DC with 19.2-30 V operating range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 5.1 W typical (8.6 W maximum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCEX Bus Supply:\u003c\/strong\u003e Maximum 2.4 A total current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulebus Supply:\u003c\/strong\u003e 24V: 1.0A max, 5V: 1.5A max\u003c\/li\u003e\n\u003cli\u003eRedundant power supply status input capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e +5 to +55 °C (+41 to +131 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to +70 °C (-40 to +158 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5 to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Altitude:\u003c\/strong\u003e 2000 meters according to IEC\/EN 61131-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e Degree 2 per IEC\/EN 61131-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20 according to EN60529\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Emission:\u003c\/strong\u003e Less than 55 dB for quiet operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE marked for European market compliance\u003c\/li\u003e\n\u003cli\u003eTÜV approved for safety instrumented systems\u003c\/li\u003e\n\u003cli\u003eUL 61010-1 and UL 61010-2-201 for electrical safety\u003c\/li\u003e\n\u003cli\u003ecULus Class 1, Zone 2 for hazardous locations\u003c\/li\u003e\n\u003cli\u003eMarine certificates: ABS, BV, DNV-GL\u003c\/li\u003e\n\u003cli\u003eEMC: EN 61000-6-4, EN 61000-6-2\u003c\/li\u003e\n\u003cli\u003eRoHS compliance: EN 50581:2012\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 119 mm (4.7 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 186 mm (7.3 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 135 mm (5.3 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1200 g (2.6 pounds) including base\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat safety level does the PM863 support?\u003c\/strong\u003e It supports up to SIL 3 with SM812 safety module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the processor performance?\u003c\/strong\u003e 0.17 ms for 1000 boolean operations at 96 MHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it support redundancy?\u003c\/strong\u003e No, the PM863K01 does not support CPU redundancy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat communication interfaces are included?\u003c\/strong\u003e Two Ethernet and two RS-232C serial ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat engineering tool is used?\u003c\/strong\u003e 800xA Control Builder for configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs TÜV certification included?\u003c\/strong\u003e Yes, it carries TÜV certification for SIL 2 and SIL 3.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2025 AutoNex Controls Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.autonexcontrol.com\/\"\u003ehttps:\/\/www.autonexcontrol.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45280738672801,"sku":"PM863K01","price":205.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/PM863K01.jpg?v=1761645494","url":"https:\/\/www.autonexcontrol.com\/cs\/products\/pm863k01-ac-800m-high-integrity-controller-abb-3bse088381r1","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}