{"product_id":"ic697mdl240-ge-fanuc-emerson-series-90-70","title":"IC697MDL240 GE Fanuc Emerson | Series 90-70","description":"\u003ch2\u003e\u003cstrong\u003eIC697MDL240 Discrete Input Module for Series 90-70\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Rating:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e120 V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Points:\u003c\/strong\u003e \u003cspan style=\"color: blue;\"\u003e16 isolated inputs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Filter Delay:\u003c\/strong\u003e \u003cspan style=\"color: green;\"\u003e20 milliseconds\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e \u003cspan style=\"color: orange;\"\u003e10 mA per point\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current:\u003c\/strong\u003e \u003cspan style=\"color: purple;\"\u003e≤4 mA off-state\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Switching Rate:\u003c\/strong\u003e 20 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 1.2 Watts total\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -20°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e Meets industrial standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e High noise rejection capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Rating:\u003c\/strong\u003e Channel-to-channel isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Steps\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the module into any available Series 90-70 rack slot\u003c\/li\u003e\n\u003cli\u003eSecure the locking latch firmly to the backplane connector\u003c\/li\u003e\n\u003cli\u003eWire 120V AC input signals to the terminal points\u003c\/li\u003e\n\u003cli\u003eUse GE programming software to map I\/O addresses\u003c\/li\u003e\n\u003cli\u003eCheck status LEDs for input on\/off indication\u003c\/li\u003e\n\u003cli\u003eVerify proper operation through system diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGE and Emerson Series 90-70 programmable controllers\u003c\/li\u003e\n\u003cli\u003eTwo-wire and three-wire proximity switch inputs\u003c\/li\u003e\n\u003cli\u003eLimit switches and mechanical position sensors\u003c\/li\u003e\n\u003cli\u003eSelector switches and control panel pushbuttons\u003c\/li\u003e\n\u003cli\u003eWindows and DOS programming tools via SNP\u003c\/li\u003e\n\u003cli\u003eEthernet-based configuration and monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003eWhat input voltage does this module accept?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC697MDL240\u003c\/strong\u003e accepts 120V AC input signals. This matches standard industrial control voltage levels.\u003c\/p\u003e\n\u003ch4\u003eHow many input points are available?\u003c\/h4\u003e\n\u003cp\u003eThis module provides sixteen completely isolated input points. Each point handles AC voltage signals independently.\u003c\/p\u003e\n\u003ch4\u003eWhat is the purpose of the 20ms filter?\u003c\/h4\u003e\n\u003cp\u003eThe 20 millisecond filter eliminates contact bounce and electrical noise. This ensures clean signal recognition for reliable operation.\u003c\/p\u003e\n\u003ch4\u003eWhat types of switches can I connect?\u003c\/h4\u003e\n\u003cp\u003eYou can connect limit switches, pushbuttons, selector switches, and proximity sensors. Both two-wire and three-wire devices are compatible.\u003c\/p\u003e\n\u003ch4\u003eHow do I monitor input status?\u003c\/h4\u003e\n\u003cp\u003eEach input point has a corresponding status LED. The PLC programming software also shows real-time input status.\u003c\/p\u003e\n\u003ch4\u003eWhat is your return policy?\u003c\/h4\u003e\n\u003cp\u003eWe offer a 30-day return period for all products. Contact our sales team for return authorization and instructions.\u003c\/p\u003e\n\u003cp\u003eFor volume pricing and technical support, reach out to our automation experts: \u003cstrong\u003e\u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139262963873,"sku":"IC697MDL240","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC697MDL240-2.jpg?v=1761637724","url":"https:\/\/www.autonexcontrol.com\/cs\/products\/ic697mdl240-ge-fanuc-emerson-series-90-70","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}