{"product_id":"emerson-modbus-module-machinery-data-interface-a6824-r","title":"Emerson ModBus Module - Machinery Data Interface A6824-R","description":"\u003ch2\u003eEmerson A6824-R: Smart Communication Hub for Machinery Monitoring\u003c\/h2\u003e\n\u003cp\u003eThe Emerson \u003cstrong\u003eA6824-R\u003c\/strong\u003e connects your machinery protection system to plant networks. This interface module reads data from all AMS 6500 monitoring modules. It shares machine health information through ModBus protocols. The \u003cstrong\u003eA6824-R\u003c\/strong\u003e ensures your team sees vital equipment data in real-time.\u003c\/p\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual ModBus TCP\/IP and RTU communication\u003c\/li\u003e\n\u003cli\u003eRedundant operation for maximum reliability\u003c\/li\u003e\n\u003cli\u003ePowers local graphical displays at the rack\u003c\/li\u003e\n\u003cli\u003eSeamless integration with control systems\u003c\/li\u003e\n\u003cli\u003eCompact design saves valuable space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2c5aa0;\"\u003eCommunication protocols\u003c\/strong\u003e: ModBus TCP\/IP and ModBus RTU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2c5aa0;\"\u003eData speed\u003c\/strong\u003e: 19.2 kbaud for serial communication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2c5aa0;\"\u003eEthernet port\u003c\/strong\u003e: RJ45 socket with 10BaseT capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2c5aa0;\"\u003eDefault IP\u003c\/strong\u003e: 192.168.255.1 with 255.255.255.0 subnet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2c5aa0;\"\u003ePower consumption\u003c\/strong\u003e: Maximum 5 watts only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2c5aa0;\"\u003eOperating temperature\u003c\/strong\u003e: 0°C to 65°C range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2c5aa0;\"\u003eData types\u003c\/strong\u003e: Speed, vibration, gap values, alarm states\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous TCP\/IP and RTU operation possible\u003c\/li\u003e\n\u003cli\u003eStandard ModBus data register mapping\u003c\/li\u003e\n\u003cli\u003eEven parity with 8 data bits and 1 stop bit\u003c\/li\u003e\n\u003cli\u003eGreen LED indicates power supply status\u003c\/li\u003e\n\u003cli\u003eEasy module removal with handle design\u003c\/li\u003e\n\u003cli\u003eWorks with PlantWeb and AMS software suites\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits standard 19-inch rack mounting systems\u003c\/li\u003e\n\u003cli\u003eOnly one slot required in AMS 6500 chassis\u003c\/li\u003e\n\u003cli\u003eHot-swappable design for easy maintenance\u003c\/li\u003e\n\u003cli\u003eSimple network configuration process\u003c\/li\u003e\n\u003cli\u003eCompatible with Ovation and DeltaV systems\u003c\/li\u003e\n\u003cli\u003eProvides data for local graphical displays\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIP00 module protection rating\u003c\/li\u003e\n\u003cli\u003eIP21 front plate protection level\u003c\/li\u003e\n\u003cli\u003eHumidity range: 5-95% non-condensing\u003c\/li\u003e\n\u003cli\u003eVibration resistant to IEC standards\u003c\/li\u003e\n\u003cli\u003eShock protection up to 98 m\/s² peak\u003c\/li\u003e\n\u003cli\u003eEMC compliance for industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNet weight: 320 grams, lightweight design\u003c\/li\u003e\n\u003cli\u003eFast worldwide delivery via FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eComplete documentation included\u003c\/li\u003e\n\u003cli\u003e12-month product warranty coverage\u003c\/li\u003e\n\u003cli\u003eReady for immediate system integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat communication protocols does this module support?\u003c\/li\u003e\n\u003cli\u003eThe A6824-R supports both ModBus TCP\/IP for Ethernet networks and ModBus RTU for serial communication, allowing flexible integration with various control systems.\u003c\/li\u003e\n\u003cli\u003eCan both communication methods work at the same time?\u003c\/li\u003e\n\u003cli\u003eYes, you can operate TCP\/IP and RTU protocols simultaneously for redundant communication paths, ensuring data always reaches your control system.\u003c\/li\u003e\n\u003cli\u003eWhat type of machinery data can it transmit?\u003c\/li\u003e\n\u003cli\u003eIt handles speed measurements, vibration data including harmonics, gap values, alarm status information, channel health status, and phase measurements from connected monitors.\u003c\/li\u003e\n\u003cli\u003eHow do I configure the network settings?\u003c\/li\u003e\n\u003cli\u003eThe module comes with default IP 192.168.255.1, but you can reconfigure this through the RS-232 interface to match your plant network requirements.\u003c\/li\u003e\n\u003cli\u003eWhat makes this module suitable for critical applications?\u003c\/li\u003e\n\u003cli\u003eIts redundant communication capability, industrial temperature rating, and compliance with machinery protection standards ensure reliable operation in demanding plant environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45339981086881,"sku":"A6824-R","price":255.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/A6824-R.jpg?v=1762755139","url":"https:\/\/www.autonexcontrol.com\/cs\/products\/emerson-modbus-module-machinery-data-interface-a6824-r","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}