{"product_id":"900a16-0103-honeywell-voltage-current-input-module","title":"900A16-0103 Honeywell Voltage Current Input Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell 900A16-0103 High Level Analog Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #d35400;\"\u003e900A16-0103\u003c\/strong\u003e is a high-density 16-channel Analog Input module for the \u003cstrong\u003eHoneywell HC900\u003c\/strong\u003e control system. Designed for voltage and current signals, it provides fast, accurate data acquisition for process monitoring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong style=\"color: #d35400;\"\u003e900A16-0103\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e High Level Analog Input (AI) Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs per Module:\u003c\/strong\u003e 16 Channels (Individually Isolated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Input Types:\u003c\/strong\u003e Voltage (V), Current (mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u0026gt;1 MΩ (Voltage Inputs), 250 Ω (Current Inputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e 400 VDC (Point-to-Point), 1 kVDC (to Logic)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\/D Converter:\u003c\/strong\u003e ±15-Bit Resolution (One per Module)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 100 ms (per module)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Calibration Accuracy:\u003c\/strong\u003e ± 0.1% of Range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Effect on Accuracy:\u003c\/strong\u003e ± 0.01% of Full Scale per °C max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Term Stability:\u003c\/strong\u003e 0.1% per Year\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Rejection (Series Mode):\u003c\/strong\u003e \u0026gt; 31 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Rejection (Common Mode):\u003c\/strong\u003e \u0026gt; 90 dB @ 120V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Range Limit:\u003c\/strong\u003e ±10% of Range (Linear Voltage Ranges)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference Conditions (for Accuracy):\u003c\/strong\u003e 25°C ±3°C, 45-55% RH, Nominal Line Voltage ±1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Storage:\u003c\/strong\u003e Non-Volatile Memory\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Monitoring of Factory Calibration, 24V DC Supply, Configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Configuration Storage:\u003c\/strong\u003e Non-Volatile Memory\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C (HC900 System Standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24V DC from Backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSupported Signal Ranges\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Inputs:\u003c\/strong\u003e 0-10V, -10 to +10V, 0-5V, 1-5V (User-configurable per channel)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Inputs:\u003c\/strong\u003e 0-20mA, 4-20mA (User-configurable per channel)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Source:\u003c\/strong\u003e Compatible with 2-wire and 4-wire transmitters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModule Features \u0026amp; Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh channel density (16 inputs) saves rack space and reduces cost per point.\u003c\/li\u003e\n\u003cli\u003ePoint-to-point isolation (400VDC) prevents cross-talk and ground loop issues between channels.\u003c\/li\u003e\n\u003cli\u003eFast 100ms update rate per module ensures timely data for control and monitoring loops.\u003c\/li\u003e\n\u003cli\u003eHigh ±15-bit A\/D resolution provides fine measurement detail for precise process control.\u003c\/li\u003e\n\u003cli\u003eIntegrated diagnostics monitor module health, power supply, and calibration status.\u003c\/li\u003e\n\u003cli\u003eStatus LEDs provide visual indication: green blinking (active scanning) and red (fault\/diagnostic).\u003c\/li\u003e\n\u003cli\u003eFactory calibration stored in non-volatile memory ensures long-term accuracy without manual recalibration.\u003c\/li\u003e\n\u003cli\u003eAll 16 channels are processed in parallel, preventing increased system scan time as modules are added.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in a compatible Honeywell HC900 rack (e.g., 900R04-0300).\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielded, twisted-pair cable for analog signals to minimize noise.\u003c\/li\u003e\n\u003cli\u003eFor current inputs (4-20mA), ensure loop power is supplied if using 2-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable separation from AC power lines and motor drives to reduce EMI.\u003c\/li\u003e\n\u003cli\u003eConfigure each channel via the HC900 configuration software for the desired voltage or current range.\u003c\/li\u003e\n\u003cli\u003eAfter installation and configuration, verify signal accuracy using a calibrated source.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor application engineering or to order the \u003cstrong\u003eHoneywell 900A16-0103\u003c\/strong\u003e, contact our technical team.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact:\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@nex-auto.com\"\u003e\u003cstrong\u003esales@nex-auto.com\u003c\/strong\u003e\u003c\/a\u003e or WhatsApp \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e\u003cstrong\u003e+86 153 9242 9628\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003e\u003cstrong\u003eNexAuto Technology Limited\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e© 2026 \u003ca href=\"https:\/\/www.autonexcontrol.com\/\"\u003e\u003cstrong\u003eAutoNex Controls Limited\u003c\/strong\u003e\u003c\/a\u003e. All rights reserved.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45621502116001,"sku":"900A16-0103","price":306.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/900A16-0103.jpg?v=1767595433","url":"https:\/\/www.autonexcontrol.com\/cs\/products\/900a16-0103-honeywell-voltage-current-input-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}