{"title":"Allen-Bradley Motors","description":"\u003cdiv class=\"document\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cp class=\"paragraph text-align-type-justify horizontal-splitline normal\"\u003e\u003cspan data-font-family=\"微软雅黑\"\u003eAllen-Bradley motors are built for durability and high efficiency. Ideal for automation and motion control systems, they deliver consistent power and smooth operation across a wide range of industrial applications.\u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","products":[{"product_id":"allen-bradley-mpl-a320p-mj22aa-servo-motor","title":"Allen-Bradley | MPL-A320P-MJ22AA Servo Motor","description":"\u003ch2\u003eMPL-A320P-MJ22AA 240V AC Rotary Servo Motor\u003c\/h2\u003e\n\u003ch3\u003eCore Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003ePower Supply:\u003c\/strong\u003e 240V AC operation with 200V AC voltage class\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eFrame Size:\u003c\/strong\u003e 100mm compact frame design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eMagnetic Stack:\u003c\/strong\u003e 2-inch (50.8mm) stack length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eSpeed Rating:\u003c\/strong\u003e 5000 RPM with ±1% accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eTorque Output:\u003c\/strong\u003e 4.2Nm continuous and 8.5Nm peak torque\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003ePeak Duration:\u003c\/strong\u003e 200ms peak torque capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eEncoder System:\u003c\/strong\u003e 20-bit multi-turn absolute encoder\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eResolution:\u003c\/strong\u003e 1,048,576 counts per revolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEncoder Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20-bit multi-turn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.754 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eTemperature Range:\u003c\/strong\u003e -20°C to +80°C operational range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eEfficiency Rating:\u003c\/strong\u003e 95% typical energy efficiency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eIngress Protection:\u003c\/strong\u003e IP65 rated bayonet connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eConnector Type:\u003c\/strong\u003e M23x1 facing shaft direction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Design\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eBearing System:\u003c\/strong\u003e Dual angular contact 6204ZZ\/C3 bearings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eMounting System:\u003c\/strong\u003e B5 flange with 6xM5 mounting holes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eRotor Inertia:\u003c\/strong\u003e 0.0021 kg·m² ±5% tolerance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2a5c9b;\"\u003eReliability:\u003c\/strong\u003e 50,000-hour MTBF at rated load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eMP-Series MPL\u003c\/strong\u003e provides precise rotary motion control\u003c\/li\u003e\n\u003cli\u003eIt features high-resolution feedback for accurate positioning\u003c\/li\u003e\n\u003cli\u003eThe motor handles demanding industrial automation tasks\u003c\/li\u003e\n\u003cli\u003eContact our team for specific application requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact our engineering team for technical support:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45139182747809,"sku":"MPL-A320P-MJ22AA","price":382.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/MPL-A320P-HJ72AA-3.jpg?v=1758189440"},{"product_id":"150-f317nbd-allen-bradley-smc-flex-motor-controller-317a-460v","title":"150-F317NBD Allen-Bradley SMC Flex Motor Controller 317A 460V","description":"\u003c!-- SEO Titles (Max 65 chars) - Place in Shopify's SEO settings --\u003e\u003c!-- 150-F317NBD Allen-Bradley SMC Flex: 317A soft starter, 200-460V AC, 3-phase. LCD display, 18 start modes, full protection. Open enclosure. In stock. --\u003e\n\u003ch2\u003e\u003cstrong\u003e150-F317NBD Allen‑Bradley SMC Flex Smart Motor Controller – 317A\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen‑Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003e150-F317NBD\u003c\/strong\u003e – SMC‑Flex series, Bulletin 150.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Voltage:\u003c\/strong\u003e 200…460V AC, 3‑phase, 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 100…240V AC (applicable for 5…480 A units).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Output Current:\u003c\/strong\u003e 317 Amperes continuous.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Output Power:\u003c\/strong\u003e 250 HP at 460V AC rated voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Type:\u003c\/strong\u003e Open – requires proper ventilation and clean environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 149.94 lbs (68.01 kg).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 600.00 x 289.97 x 276.50 mm (23.62 x 11.42 x 10.88 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -5°C to +50°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eExtensive Operating Modes \u0026amp; Control Flexibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart modes:\u003c\/strong\u003e Soft Start, Full Voltage, Current Limit, Dual Ramp, Pump Start, Kickstart, Linear Speed Acceleration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStop modes:\u003c\/strong\u003e Soft Stop, Pump Stop, Accu-Stop, Coast-to-rest, Smart Motor Braking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlow speed modes:\u003c\/strong\u003e Preset Slow Speed, Slow Speed with Braking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomisable parameters:\u003c\/strong\u003e Adjustable initial torque (0‑90% of locked rotor torque) and acceleration ramp time (0‑30 seconds).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKickstart option:\u003c\/strong\u003e Provides initial high torque for high‑friction loads when combined with soft start.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIntegrated Protection, Diagnostics \u0026amp; Metering\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtections:\u003c\/strong\u003e Power loss, line fault, voltage unbalance, phase reversal, undervoltage\/overvoltage, controller overtemp, stall, jam, open gate, overload, underload, communication fault, excessive starts\/hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal‑time metering:\u003c\/strong\u003e Displays Amps, Volts, kW, kWh, MW, MWh, elapsed time, power factor, motor thermal capacity usage on the integral LCD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary contacts:\u003c\/strong\u003e Four fully programmable contacts (N.O.\/N.C.) for normal\/up‑to‑speed\/fault\/alarm\/network indication, or external bypass (N.O. only).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunications:\u003c\/strong\u003e Two DPI ports – one for optional human interface module, one for communication adapters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the main advantages of the \u003cstrong\u003e150-F317NBD\u003c\/strong\u003e over basic soft starters?\u003c\/strong\u003e\u003cbr\u003eIt offers 18 operating modes, comprehensive metering (kW, power factor, thermal capacity), and extensive protection features not found in entry‑level units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I program this controller without additional software?\u003c\/strong\u003e\u003cbr\u003eYes, the integral backlit LCD display and built‑in keypad allow full programming and monitoring without any external tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the \u003cstrong\u003e150-F317NBD\u003c\/strong\u003e support communication networks?\u003c\/strong\u003e\u003cbr\u003eIt includes two DPI ports; you can connect optional communication modules (like DeviceNet, EtherNet\/IP) via one port, and an optional HMI via the other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the difference between Soft Stop and Pump Stop?\u003c\/strong\u003e\u003cbr\u003eSoft Stop linearly reduces voltage to decelerate smoothly; Pump Stop is optimised to reduce hydraulic shock in pumping systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs external overload protection required?\u003c\/strong\u003e\u003cbr\u003eNo, the controller has integrated electronic overload protection based on motor thermal capacity usage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I obtain the full technical manual for the \u003cstrong\u003e150-F317NBD\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eRequest the PDF via email (see below) – we will send the latest Allen‑Bradley SMC‑Flex user documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top: 20px;\"\u003eFor technical or sales inquiries, contact us: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628 (WhatsApp)\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\" rel=\"noopener\" target=\"_blank\"\u003eNexAuto Technology Limited\u003c\/a\u003e – your trusted source for industrial automation.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45789243310241,"sku":"150-F317NBD","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F317NBD-1.jpg?v=1773815500"},{"product_id":"150-f85nbr-motor-controller-85a-460v-allen-bradley","title":"150-F85NBR | Motor Controller 85A 460V Allen-Bradley","description":"\u003ch2\u003e\u003cstrong\u003e150-F85NBR Allen‑Bradley SMC Flex Smart Motor Controller – 85A\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen‑Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003e150-F85NBR\u003c\/strong\u003e – SMC‑Flex series, Bulletin 150.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Voltage:\u003c\/strong\u003e 200‑460V AC, 3‑phase, 47‑63 Hz (50\/60 Hz rated).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24V AC\/DC (for 5‑480 A units).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 85 Amps, 60 HP @ 460V AC (line connected).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine‑Connected Output:\u003c\/strong\u003e 17‑85A, 25‑60 HP @60 Hz, 22‑45 kW @50 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta‑Connected Output:\u003c\/strong\u003e 29.4‑147A, 40‑100 HP @60 Hz, 45‑75 kW @50 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Type:\u003c\/strong\u003e Open – requires cabinet mounting with ventilation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 12.50 lbs (5.67 kg).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -5°C to +40°C; storage -20°C to +75°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMultiple Operating Modes \u0026amp; Adjustable Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart\/stop modes:\u003c\/strong\u003e Soft Start, Kickstart, Current Limit, Pump Control, Dual Ramp, Full Voltage, Coast, Soft Stop, Smart Motor Braking, Preset Slow Speed, Linear Speed Acceleration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKickstart adjustments:\u003c\/strong\u003e Selectable 0, 0.5, 1.0, or 1.5 seconds at 450% full load current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart time adjustments:\u003c\/strong\u003e 2, 5, 10, 15, 20, 25, or 30 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent limit settings:\u003c\/strong\u003e 150%, 250%, 350%, and 450% of full load current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload trip class:\u003c\/strong\u003e Selectable Trip Class 10, 15, or 20.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat types of motors work with the \u003cstrong\u003e150-F85NBR\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eIt supports standard three‑phase squirrel‑cage induction motors and six‑lead Wye‑Delta motors, both line‑connected or delta‑connected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I select the correct current range for my motor?\u003c\/strong\u003e\u003cbr\u003eFor line connection use 17‑85A range; for delta connection use 29.4‑147A range – refer to motor nameplate FLA and connection type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I adjust the kickstart duration?\u003c\/strong\u003e\u003cbr\u003eYes, you can set kickstart to 0, 0.5, 1.0, or 1.5 seconds at 450% FLA via the integrated keypad.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the \u003cstrong\u003e150-F85NBR\u003c\/strong\u003e include overload protection?\u003c\/strong\u003e\u003cbr\u003eYes, it has built‑in electronic overload with selectable Trip Class 10, 15, or 20.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat information does the LCD display show?\u003c\/strong\u003e\u003cbr\u003eIt shows Amps, Volts, kW, power factor, thermal capacity, elapsed time, and fault messages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I obtain the full technical manual for the \u003cstrong\u003e150-F85NBR\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eRequest the PDF via email (see below) – we will provide the official Allen‑Bradley SMC‑Flex documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top: 20px;\"\u003eFor technical or sales inquiries, contact us: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628 (WhatsApp)\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\" rel=\"noopener\" target=\"_blank\"\u003eNexAuto Technology Limited\u003c\/a\u003e – your trusted source for industrial automation.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45789244031137,"sku":"150-F85NBR","price":254.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F85NBDB.jpg?v=1773815500"},{"product_id":"150-f43nbdb-soft-starter-43-amp-200-460v-allen-bradley","title":"150-F43NBDB - Soft Starter 43 Amp 200-460V Allen-Bradley","description":"\u003c!-- SEO Titles (Max 65 chars) - Place in Shopify's SEO settings --\u003e\n\u003ch2\u003e\u003cstrong\u003e150-F43NBDB Allen‑Bradley SMC Flex Smart Motor Controller – 43A with Pump Control\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen‑Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003e150-F43NBDB\u003c\/strong\u003e – SMC‑Flex series, Bulletin 150.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Voltage:\u003c\/strong\u003e 200‑460V AC, 3‑phase, 47‑63 Hz (50\/60 Hz rated).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 100‑240V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 43 Amps, 30 HP at 460V AC (line connected).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine‑Connected Output:\u003c\/strong\u003e 8.6‑43A, 10‑30 HP @60 Hz, 11‑22 kW @50 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta‑Connected Output:\u003c\/strong\u003e 14.9‑74A, 20‑50 HP @60 Hz, 22‑37 kW @50 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Type:\u003c\/strong\u003e Open – requires mounting inside a protective cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 13.00 lbs (5.90 kg).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Enclosure Size:\u003c\/strong\u003e 406 mm (H) x 305 mm (W) x 203 mm (D).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdvanced Operating Modes \u0026amp; Pump Control Feature\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart\/stop modes:\u003c\/strong\u003e Soft Start, Kickstart, Current Limit, Pump Control, Dual Ramp, Full Voltage, Coast, Soft Stop, Smart Motor Braking, Preset Slow Speed, Linear Speed Acceleration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt‑in pump control:\u003c\/strong\u003e Includes anti‑backspin timer to prevent fluid hammer and surge damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKickstart adjustments:\u003c\/strong\u003e Selectable 0, 0.5, 1.0, or 1.5 seconds at 450% full load current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart time adjustments:\u003c\/strong\u003e 2, 5, 10, 15, 20, 25, or 30 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent limit settings:\u003c\/strong\u003e 150%, 250%, 350%, and 450% of full load current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload trip class:\u003c\/strong\u003e Selectable Trip Class 10, 15, or 20.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eComprehensive Protection, Metering \u0026amp; I\/O\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection diagnostics:\u003c\/strong\u003e Power loss, line fault, voltage unbalance, excessive starts\/hour, phase reversal, undervoltage\/overvoltage, controller temp, stall, jam, open gate, overload, underload, communication fault, ground fault.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal‑time metering:\u003c\/strong\u003e Displays Amps, Volts, kW, kWh, MW, MWh, elapsed time, power factor, motor thermal capacity usage on integrated LCD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary contacts:\u003c\/strong\u003e Four fully programmable contacts for status, alarm, or external bypass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput contacts:\u003c\/strong\u003e One N.O. + one N.C. for basic control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm contact assignments:\u003c\/strong\u003e Overload, underload, undervoltage, overvoltage, unbalance, jam, stall, ground fault.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus indicators:\u003c\/strong\u003e Stopped, starting, stopping, at speed, alarm, fault (LED + LCD).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication ports:\u003c\/strong\u003e Two DPI ports – one for optional HMI, one for expansion modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat makes the \u003cstrong\u003e150-F43NBDB\u003c\/strong\u003e different from standard SMC Flex controllers?\u003c\/strong\u003e\u003cbr\u003eIt includes built‑in pump control with anti‑backspin timer, specifically designed to prevent fluid surges in pumping systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat motor types are compatible with the \u003cstrong\u003e150-F43NBDB\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eIt supports standard three‑phase squirrel‑cage induction motors and six‑lead Wye‑Delta motors, both line‑connected or delta‑connected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I select the correct current range for my motor?\u003c\/strong\u003e\u003cbr\u003eFor line connection use 8.6‑43A range; for delta connection use 14.9‑74A range – refer to motor nameplate FLA and connection type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this controller provide overload protection?\u003c\/strong\u003e\u003cbr\u003eYes, it features built‑in electronic overload protection using an I²t algorithm with selectable Trip Class 10, 15, or 20.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I monitor energy consumption with this unit?\u003c\/strong\u003e\u003cbr\u003eYes, the integrated metering displays Amps, Volts, kW, kWh, power factor, and motor thermal capacity usage in real time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I obtain the full technical manual for the \u003cstrong\u003e150-F43NBDB\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eRequest the PDF via email (see below) – we will provide the official Allen‑Bradley SMC‑Flex documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top: 20px;\"\u003eFor technical or sales inquiries, contact us: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628 (WhatsApp)\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\" rel=\"noopener\" target=\"_blank\"\u003eNexAuto Technology Limited\u003c\/a\u003e – your trusted source for industrial automation.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45789258219681,"sku":"150-F43NBDB","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F43NBDB.jpg?v=1773817235"},{"product_id":"150-f25nbd-allen-bradley-smc-flex-smart-motor-controller","title":"150-F25NBD Allen-Bradley SMC Flex Smart Motor Controller","description":"\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e150-F25NBD\u003c\/strong\u003e Allen‑Bradley SMC‑Flex 25A Smart Motor Controller\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c00000;\"\u003eBrand:\u003c\/span\u003e Allen‑Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c00000;\"\u003eModel:\u003c\/span\u003e \u003cstrong\u003e150-F25NBD\u003c\/strong\u003e (Bulletin 150 SMC‑Flex)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c00000;\"\u003eInput voltage:\u003c\/span\u003e 200–460V AC, 3‑phase, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c00000;\"\u003eControl voltage:\u003c\/span\u003e 100–240V AC (120\/240 VAC nominal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c00000;\"\u003eCurrent rating:\u003c\/span\u003e 25 A continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c00000;\"\u003ePower output:\u003c\/span\u003e 15 HP @460V line connection; 30 HP @460V delta connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c00000;\"\u003eEnclosure:\u003c\/span\u003e Open type (IP00), weight 2.49 kg (5.50 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c00000;\"\u003eProtection features:\u003c\/span\u003e Programmable overload, short‑circuit, and electronic motor safeguards\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c00000;\"\u003eAuxiliary contacts:\u003c\/span\u003e Four configurable (N.O.\/N.C.) for fault, alarm, up‑to‑speed, or bypass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently asked questions – \u003cstrong\u003e150-F25NBD\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the \u003cstrong\u003e150-F25NBD\u003c\/strong\u003e a new original unit?\u003c\/strong\u003e Yes, we supply only brand new, factory‑sealed Allen‑Bradley devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat starting modes does this controller offer?\u003c\/strong\u003e You can select soft start, current limiting start, or full‑voltage start directly from the keypad.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have stock and how fast do you ship?\u003c\/strong\u003e We keep \u003cstrong\u003e150-F25NBD\u003c\/strong\u003e in stock; we dispatch within 5 days via DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return this product if it doesn’t fit?\u003c\/strong\u003e Yes, we accept returns within 30 days – the unit must be unused and in original packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this controller support external HIM modules?\u003c\/strong\u003e Yes, you can attach hand‑held or door‑mounted HIMs (cables available separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca rel=\"noopener\" href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e (WhatsApp)\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca rel=\"noopener\" href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45789268344993,"sku":"150-F25NBD","price":255.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F25NBD.jpg?v=1773817493"},{"product_id":"1790d-8bv8b-allen-bradley-8-input-8-output-base-module","title":"1790D-8BV8B Allen-Bradley 8 Input\/8 Output Base Module","description":"\u003ch2\u003e\u003cstrong\u003e1790D-8BV8B Allen-Bradley 24V DC 8 Universal Input\/8 Sourcing Output Base Module Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Input Specifications for 1790D-8BV8B\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eInput Electrical Ratings:\u003c\/strong\u003e\u003c\/span\u003e The \u003cstrong\u003e1790D-8BV8B\u003c\/strong\u003e operates at 24V DC nominal with a 9.6…28.8V DC range. Maximum on-state current reaches 8 mA per point at 28.8V DC. Off-state voltage measures 5V DC maximum for reliable signal distinction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eInput Impedance \u0026amp; Indicators:\u003c\/strong\u003e\u003c\/span\u003e Nominal input impedance sits at 4.8 KΩ for consistent performance. Eight green status LEDs show the real-time state of each input channel. The common configuration uses 8 points with 8 commons and features nonpolarity wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Output Specifications for 1790D-8BV8B\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eOutput Electrical Ratings:\u003c\/strong\u003e\u003c\/span\u003e Outputs operate at 24V DC nominal with a 10…28.8V DC range. Maximum output current rating is 0.5 A per output with 4.0 A maximum per common. On-state voltage drop stays below 0.5V DC max for efficient power delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eOutput Speed \u0026amp; Leakage:\u003c\/strong\u003e\u003c\/span\u003e Minimum on-state current requirement is just 1 mA per channel. Maximum off-state leakage current is 0.5 mA for reliable off signals. Output signal delay measures 0.5 ms max for Off to On and 1.0 ms max for On to Off transitions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eOutput Indicators \u0026amp; Common:\u003c\/strong\u003e\u003c\/span\u003e Eight green status indicators monitor each output channel in real time. The common type uses 8 points with 8 commons specifically for the \u003cstrong\u003e1790D-8BV8B\u003c\/strong\u003e configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral Specifications and Power Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eDeviceNet Power for Base Module:\u003c\/strong\u003e\u003c\/span\u003e DeviceNet power supply requires 24V DC nominal with an 11…28.8V DC range. Maximum power dissipation reaches 1.2 W at 28.8V DC for energy efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eField Power Specifications:\u003c\/strong\u003e\u003c\/span\u003e Field power operates at 24V DC nominal with a 10…28.8V DC range. Power dissipation measures 6 mA at 28.8V DC per point for controlled consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eIsolation and Wiring Details:\u003c\/strong\u003e\u003c\/span\u003e Photocoupler isolation protects I\/O circuits from logic with 1250V AC rms rating. DeviceNet to logic and DeviceNet power sections remain nonisolated. Wiring connects easily through the standard 37-pin D-shell connector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions about 1790D-8BV8B\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eIs the 1790D-8BV8B a brand new product?\u003c\/strong\u003e\u003c\/span\u003e Yes, we supply the \u003cstrong\u003e1790D-8BV8B\u003c\/strong\u003e as a brand new, original Allen-Bradley module. It meets all factory specifications and quality standards without exception.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eWhat is the current stock availability?\u003c\/strong\u003e\u003c\/span\u003e We maintain the 1790D-8BV8B in stock and ready for immediate shipment. You can place your order with confidence in our inventory levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eHow quickly can you ship this module?\u003c\/strong\u003e\u003c\/span\u003e We ship all orders within 5 business days of confirmation. Our logistics partners include FedEx, UPS, and DHL for worldwide delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eWhat is your return policy for this item?\u003c\/strong\u003e\u003c\/span\u003e We offer a 30-day return window for the 1790D-8BV8B. Please return the item in its original condition for full consideration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eCan the inputs handle both sinking and sourcing signals?\u003c\/strong\u003e\u003c\/span\u003e Yes, the eight inputs on the \u003cstrong\u003e1790D-8BV8B\u003c\/strong\u003e accept both sinking and sourcing configurations. This flexibility simplifies wiring with various sensor types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eWhat is the maximum output current per channel?\u003c\/strong\u003e\u003c\/span\u003e Each output channel supports up to 0.5 A maximum current. The common point can handle up to 4.0 A total across all channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cstrong\u003eDoes this module provide status indication?\u003c\/strong\u003e\u003c\/span\u003e Yes, the module includes eight green status LEDs for inputs and eight for outputs. This gives you immediate visual feedback for troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner NexAuto Technology Limited :\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45826648572065,"sku":"1790D-8BV8B","price":248.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/1790D-8BV8B.jpg?v=1780900124"},{"product_id":"1790d-8bv8v-allen-bradley-8-input-8-sinking-output-base-module","title":"1790D-8BV8V Allen-Bradley 8 Input\/8 Sinking Output Base Module","description":"\u003ch2\u003e\u003cstrong\u003e1790D-8BV8V Allen-Bradley 24V DC 8 Universal Input\/8 Sinking Output Base Module Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Input Specifications for 1790D-8BV8V\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eInput Electrical Ratings:\u003c\/strong\u003e\u003c\/span\u003e The \u003cstrong\u003e1790D-8BV8V\u003c\/strong\u003e operates at 24V DC nominal with a 9.6…28.8V DC range. Maximum on-state current reaches 8 mA per point at 28.8V DC. Off-state voltage measures 5V DC maximum for reliable signal discrimination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eInput Impedance \u0026amp; Indicators:\u003c\/strong\u003e\u003c\/span\u003e Nominal input impedance sits at 4.8 KΩ for consistent signal processing. Eight green status LEDs show the real-time state of each input channel. The common configuration uses 8 points with 8 commons featuring nonpolarity wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Output Specifications for 1790D-8BV8V\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eOutput Electrical Ratings:\u003c\/strong\u003e\u003c\/span\u003e Sinking outputs operate at 24V DC nominal with a 10…28.8V DC range. Maximum output current rating is 0.5 A per output with 4.0 A maximum per common. On-state voltage drop stays below 0.5V DC max for efficient operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eOutput Speed \u0026amp; Leakage:\u003c\/strong\u003e\u003c\/span\u003e Minimum on-state current requirement is just 1 mA per channel for reliable switching. Maximum off-state leakage current is 0.5 mA for clean off signals. Output signal delay measures 0.5 ms max for Off to On and 1.0 ms max for On to Off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eOutput Indicators \u0026amp; Common:\u003c\/strong\u003e\u003c\/span\u003e Eight green status indicators monitor each sinking output channel in real time. The common type uses 8 points with 8 commons for flexible wiring arrangements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral Specifications and Power Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eDeviceNet Power for Base Module:\u003c\/strong\u003e\u003c\/span\u003e DeviceNet power supply requires 24V DC nominal with an 11…28.8V DC range. Maximum power dissipation reaches 1.2 W at 28.8V DC for energy efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eField Power Specifications:\u003c\/strong\u003e\u003c\/span\u003e Field power operates at 24V DC nominal with a 10…28.8V DC range. Power dissipation measures 6 mA at 28.8V DC per point for controlled consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eIsolation and Wiring Details:\u003c\/strong\u003e\u003c\/span\u003e Photocoupler isolation protects I\/O circuits from logic with 1250V AC rms rating. DeviceNet to logic and DeviceNet power sections remain nonisolated. Wiring connects easily through the standard 37-pin D-shell connector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions about 1790D-8BV8V\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eIs the 1790D-8BV8V a brand new product?\u003c\/strong\u003e\u003c\/span\u003e Yes, we supply the \u003cstrong\u003e1790D-8BV8V\u003c\/strong\u003e as a brand new, original Allen-Bradley module. It meets all factory specifications and quality standards without exception.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eWhat is the current stock availability?\u003c\/strong\u003e\u003c\/span\u003e We maintain the 1790D-8BV8V in stock and ready for immediate shipment. You can place your order with confidence in our inventory levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eHow quickly can you ship this module?\u003c\/strong\u003e\u003c\/span\u003e We ship all orders within 5 business days of confirmation. Our logistics partners include FedEx, UPS, and DHL for worldwide delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eWhat is your return policy for this item?\u003c\/strong\u003e\u003c\/span\u003e We offer a 30-day return window for the 1790D-8BV8V. Please return the item in its original condition for full consideration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eWhat is the difference between 1790D-8BV8B and 1790D-8BV8V?\u003c\/strong\u003e\u003c\/span\u003e The \u003cstrong\u003e1790D-8BV8V\u003c\/strong\u003e features sinking outputs while the 1790D-8BV8B provides sourcing outputs. Both share identical input specifications and general characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eCan the inputs handle both sinking and sourcing signals?\u003c\/strong\u003e\u003c\/span\u003e Yes, the eight inputs on the \u003cstrong\u003e1790D-8BV8V\u003c\/strong\u003e accept both sinking and sourcing configurations. This flexibility simplifies wiring with various sensor types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eWhat is the maximum output current per channel?\u003c\/strong\u003e\u003c\/span\u003e Each sinking output channel supports up to 0.5 A maximum current. The common point can handle up to 4.0 A total across all channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #993366;\"\u003e\u003cstrong\u003eDoes this module provide status indication?\u003c\/strong\u003e\u003c\/span\u003e Yes, the module includes eight green status LEDs for inputs and eight for outputs. This gives you immediate visual feedback for troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner NexAuto Technology Limited :\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45826729771169,"sku":"1790D-8BV8V","price":248.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/1790D-8BV8V.jpg?v=1780975363"},{"product_id":"1790d-n0c2-allen-bradley-2-channel-analog-output-module","title":"1790D-N0C2 Allen-Bradley 2-Channel Analog Output Module","description":"\u003ch2\u003e\u003cstrong\u003e1790D-N0C2 2-channel Analog Current Output Module by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Series:\u003c\/strong\u003e Allen‑Bradley CompactBlock LDX series – model \u003cstrong\u003e1790D-N0C2\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e Two single‑ended, non‑isolated channels; each configurable for 0…20 mA current loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution \u0026amp; Data:\u003c\/strong\u003e 12‑bit resolution (4.88 µA\/bit) with binary data format from 0000 to 0FFF (max scale).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy \u0026amp; Speed:\u003c\/strong\u003e Overall accuracy ±0.2 % full scale @ 0…55 °C; conversion time only 2 ms per channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad \u0026amp; Isolation:\u003c\/strong\u003e Supports external load up to 600 Ω; photocoupler isolation between I\/O and logic (1250 V AC rms tested).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e DeviceNet supply 24 V DC nom (11…28.8 V DC, 1.2 W max); field power 24 V DC nom (21.6…26.4 V DC, 1.5 W max).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators \u0026amp; Wiring:\u003c\/strong\u003e Two red\/green I\/O status LEDs; connection via 37‑pin D‑shell female connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion Capability:\u003c\/strong\u003e This analog base module accepts up to two discrete expansion modules directly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical \u0026amp; Environmental Highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Minimum 20 MΩ at 250 V DC between insulated circuits ensures reliable isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e Rated for operation 0…55 °C with full accuracy; suitable for industrial control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon‑Isolated Sections:\u003c\/strong\u003e DeviceNet to logic and field power are non‑isolated – refer to wiring manual for proper grounding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Saves panel space while offering two high‑resolution analog outputs and expansion flexibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the 1790D-N0C2 require calibration before use?\u003c\/strong\u003e No, the module needs no field calibration – it ships factory‑calibrated and maintains 0.2 % accuracy over 0…55 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat maximum load resistance can I connect to each output?\u003c\/strong\u003e You can connect up to 600 Ω external load per channel while maintaining full 0…20 mA output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this module with both 0…20 mA and 4…20 mA devices?\u003c\/strong\u003e Yes, the hardware outputs 0…20 mA, so you can scale your program to utilize any subset like 4…20 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the 1790D-N0C2 isolated from the network side?\u003c\/strong\u003e I\/O to logic uses photocoupler isolation (1250 V AC), but DeviceNet to logic is non‑isolated – observe system grounding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many expansion modules can I attach?\u003c\/strong\u003e This analog base supports a maximum of two discrete expansion modules – ideal for mixed I\/O needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the typical conversion time for both channels?\u003c\/strong\u003e The module updates each channel in 2 ms, so total cycle time for both channels is 4 ms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor technical inquiries or volume pricing, contact our sales team at \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or via WhatsApp \u003ca href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e. \u003cbr\u003ePartner website: \u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45826867855521,"sku":"1790D-N0C2","price":248.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/1790D-N0C2.jpg?v=1780975474"},{"product_id":"1790d-n4c0-allen-bradley-4-channel-analog-current-input-module","title":"1790D-N4C0 Allen-Bradley 4-Channel Analog Current Input Module","description":"\u003ch2\u003e\u003cstrong\u003e1790D-N4C0 4‑channel Analog Current Input Module by Allen‑Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Series:\u003c\/strong\u003e Allen‑Bradley CompactBlock LDX series – model \u003cstrong\u003e1790D-N4C0\u003c\/strong\u003e analog input module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e Four single‑ended, non‑isolated channels; software‑configurable for 4…20 mA (default) or 0…20 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution \u0026amp; Data:\u003c\/strong\u003e 12‑bit unipolar resolution (3.90 µA\/bit for 4…20 mA, 4.88 µA\/bit for 0…20 mA) with binary data format 0000 to 0FFF.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy \u0026amp; Speed:\u003c\/strong\u003e Overall accuracy ±0.2 % full scale @ 0…55 °C; conversion time 10 ms per channel (40 ms for all four).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance \u0026amp; Isolation:\u003c\/strong\u003e 249 Ω input impedance; photocoupler isolation between I\/O and logic (1250 V AC rms tested).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e DeviceNet supply 24 V DC nom (11…28.8 V DC, 1.2 W max); field power 24 V DC nom (21.6…26.4 V DC, 1.5 W max).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators \u0026amp; Wiring:\u003c\/strong\u003e Four red\/green I\/O status LEDs; connection via 37‑pin D‑shell female connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion Capability:\u003c\/strong\u003e This analog base module supports up to two discrete expansion modules directly attached.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical \u0026amp; Environmental Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Minimum 20 MΩ at 250 V DC between insulated circuits ensures stable isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e Full accuracy from 0…55 °C makes it suitable for industrial cabinet environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon‑Isolated Sections:\u003c\/strong\u003e DeviceNet to logic and field power are non‑isolated – follow proper grounding practices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace‑Saving Design:\u003c\/strong\u003e Four high‑resolution inputs in one housing with expansion capability reduces panel footprint.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the 1790D-N4C0 support both 4…20mA and 0…20mA inputs?\u003c\/strong\u003e Yes, you can configure each channel via software for either 4…20 mA (default) or 0…20 mA range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the input impedance of each channel?\u003c\/strong\u003e Each analog input presents 249 Ω to the loop – compatible with most transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow fast does the module read all four channels?\u003c\/strong\u003e Conversion takes 10 ms per channel, so a complete scan of four inputs requires 40 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs field calibration required for the 1790D-N4C0?\u003c\/strong\u003e No calibration needed – the module ships factory‑calibrated and maintains accuracy over temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I add expansion modules to this analog base?\u003c\/strong\u003e Yes, you can attach up to two discrete expansion modules directly to this base unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat isolation does the module provide?\u003c\/strong\u003e Photocoupler isolation between I\/O and logic (1250 V AC), but DeviceNet and field power are non‑isolated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor inquiries or volume discounts, contact our team at \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or via WhatsApp \u003ca href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e. \u003cbr\u003ePartner website: \u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45826897510561,"sku":"1790D-N4C0","price":248.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/1790D-N4C0.jpg?v=1780975595"},{"product_id":"150-f201nbdd-allen-bradley-motor-controller-201a-150hp","title":"150-F201NBDD Allen-Bradley Motor Controller 201A 150HP","description":"\u003ch2\u003e\u003cstrong\u003e150-F201NBDD Allen-Bradley Smart Motor Controller – 201 A, 150 HP at 460 V AC\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F201NBDD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Phases:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 201 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 460 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 200\/690 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rating:\u003c\/strong\u003e 150 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 100...240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBraking Control:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP2X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Operating Temperature:\u003c\/strong\u003e -5°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Operating Temperature:\u003c\/strong\u003e 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\/Approvals:\u003c\/strong\u003e UL 508, cULus Listed, CCC, EN\/IEC 60947-1, EN\/IEC 60947-4-2, CSA, CE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F201NBDD?\u003c\/strong\u003e\u003cbr\u003eA: The controller handles 201 A for three-phase motor circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What motor power does this unit support?\u003c\/strong\u003e\u003cbr\u003eA: It delivers 150 HP at 460 V AC and supports 480 V AC systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this Smart Motor Controller include braking control?\u003c\/strong\u003e\u003cbr\u003eA: Yes, braking control is built into the unit for faster stops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does the 150-F201NBDD use?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 100...240 V AC for control input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The unit works from -5°C to 50°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the enclosure open or closed?\u003c\/strong\u003e\u003cbr\u003eA: This model comes with an open enclosure for panel mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the IP rating?\u003c\/strong\u003e\u003cbr\u003eA: The IP2X rating protects against finger contact and solid objects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which standards does this controller meet?\u003c\/strong\u003e\u003cbr\u003eA: It meets UL 508, cULus Listed, CCC, EN\/IEC 60947-1, EN\/IEC 60947-4-2, CSA, and CE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have this item in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we keep new original stock available for immediate order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days using DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we support returns within 30 days for eligible orders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone\/WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47173860786337,"sku":"150-F201NBDD","price":258.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F201NBDD.jpg?v=1789099230"},{"product_id":"150-f361nbrb-allen-bradley-smc-flex-soft-starter-361a","title":"150-F361NBRB Allen-Bradley SMC Flex Soft Starter 361A","description":"\u003ch2\u003e\u003cstrong\u003e150-F361NBRB Allen-Bradley SMC Flex Low Voltage Soft Starter – 361 A, 150…300 HP\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F361NBRB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Solid State Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex Low Voltage Soft Starter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Bulletin 150, Solid State Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Type:\u003c\/strong\u003e Open\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 361 A, 150…300 HP at 460 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Voltage:\u003c\/strong\u003e 200…480 V AC, 3-Phase, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24 V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Option:\u003c\/strong\u003e Pump Control Option\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 90…520 A with solid-state power structure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBypass Current Range:\u003c\/strong\u003e 108…480 A with internal bypass power structure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 200…690 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart\/Stop Modes:\u003c\/strong\u003e 17 modes included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecial Operating Modes:\u003c\/strong\u003e 4 modes included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Expansion Ports:\u003c\/strong\u003e 3 ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection:\u003c\/strong\u003e Built-in electronic motor overload protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Optional modules support multiple networks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e Connected Components Workbench™ software\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImportant Note:\u003c\/strong\u003e 24 V AC\/DC control requires separate 120 V or 240 V single phase for fan operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F361NBRB?\u003c\/strong\u003e\u003cbr\u003eA: The controller is rated 361 A for three-phase motor circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What motor power does this soft starter support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 150…300 HP at 460 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What input line voltage does this model accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 200…480 V AC, three-phase, 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does the 150-F361NBRB use?\u003c\/strong\u003e\u003cbr\u003eA: It uses 24 V AC\/DC for control input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this model include pump control?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the pump control option is included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many start and stop modes does it offer?\u003c\/strong\u003e\u003cbr\u003eA: It includes 17 start and stop modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it have built-in motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, electronic motor overload protection is built in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I program this soft starter with software?\u003c\/strong\u003e\u003cbr\u003eA: Yes, you can use Connected Components Workbench™ software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does fan operation need a separate supply?\u003c\/strong\u003e\u003cbr\u003eA: Yes, 24 V AC\/DC control requires separate 120 V or 240 V single phase for fan operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have this item in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we keep new original stock available for order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days using DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we support returns within 30 days for eligible orders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone\/WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47173861376161,"sku":"150-F361NBRB","price":258.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F361NBRB.jpg?v=1789105222"},{"product_id":"150-f625nbab-allen-bradley-smc-flex-controller","title":"150-F625NBAB Allen-Bradley SMC Flex Controller","description":"\u003ch2\u003e\u003cstrong\u003e150-F625NBAB Allen-Bradley SMC Flex Open Smart Motor Controller – 625 A, 500 HP\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F625NBAB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Solid State Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex Open Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Bulletin 150, Solid State Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Type:\u003c\/strong\u003e Open\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 625 A, 500 HP at 460 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Voltage:\u003c\/strong\u003e 200…480 V AC, 3-Phase, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 230…240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Option:\u003c\/strong\u003e Pump Control Option\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection:\u003c\/strong\u003e Built-in electronic motor overload protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Optional modules support multiple networks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e Connected Components Workbench™ software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F625NBAB?\u003c\/strong\u003e\u003cbr\u003eA: The controller is rated 625 A for three-phase motor circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What motor power does this controller support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 500 HP at 460 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What input line voltage does this model accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 200…480 V AC, three-phase, 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does the 150-F625NBAB use?\u003c\/strong\u003e\u003cbr\u003eA: It uses 230…240 V AC for control input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this model include pump control?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the pump control option is included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it have built-in motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, electronic motor overload protection is built in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I program this controller with software?\u003c\/strong\u003e\u003cbr\u003eA: Yes, you can use Connected Components Workbench™ software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have this item in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we keep new original stock available for order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days using DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we support returns within 30 days for eligible orders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone\/WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47173873041569,"sku":"150-F625NBAB","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F625NBAB.jpg?v=1789105503"},{"product_id":"150-f108nbrb-allen-bradley-smc-flex-soft-starter","title":"150-F108NBRB Allen-Bradley SMC Flex Soft Starter","description":"\u003ch2\u003e\u003cstrong\u003e150-F108NBRB SMC Flex Smart Motor Controller – 108 A Soft Starter by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F108NBRB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Soft Starter \/ Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 108 A, 20–75 Hp @ 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage (Ue):\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Control Supply Voltage:\u003c\/strong\u003e 24 V AC at 50\/60 Hz; 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current (Line Connected):\u003c\/strong\u003e 27 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current (Delta Connected):\u003c\/strong\u003e 47 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Soft starter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Options:\u003c\/strong\u003e Pump control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Classes:\u003c\/strong\u003e 10, 15, 20, and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Current Rating:\u003c\/strong\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransformer Control Module:\u003c\/strong\u003e 75VA @ 100–240V AC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatsink Fan Rating:\u003c\/strong\u003e 20VA @ 110\/120V AC or 220\/240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT Protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive Peak Inverse Voltage:\u003c\/strong\u003e 1400V per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Power (Max):\u003c\/strong\u003e 90 kW @ 690V\/Y AC, 50 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Power (Max):\u003c\/strong\u003e 90 kW @ 400\/415V AC, 50 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Voltage:\u003c\/strong\u003e 6000V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Withstand:\u003c\/strong\u003e 2500V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Current:\u003c\/strong\u003e 27–108 A @ 600\/Y\/690V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Current:\u003c\/strong\u003e 47–187 A @ 500\/575V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Metal oxide varistors: 220 J (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e Rated 500V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e 200–480V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Current:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection Device List:\u003c\/strong\u003e Standard fuse, circuit breaker, and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Contacts:\u003c\/strong\u003e 1 for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity Available Fault Current (Max):\u003c\/strong\u003e 70kA @ 600V, maximum current 300 A time delay Class J or Class L fuse for inside delta connected motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Current:\u003c\/strong\u003e AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional Thermal Current (Ith):\u003c\/strong\u003e AC\/DC: 5 A for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Control Circuit:\u003c\/strong\u003e Electromagnetic relay for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Contacts:\u003c\/strong\u003e Programmable NO\/NC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilization Category:\u003c\/strong\u003e MG 1 per UL\/CSA\/NEMA for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Controller Feature:\u003c\/strong\u003e Status indication: stopped, starting, stopping, at speed, alarm, and fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Available Fault Current (Max):\u003c\/strong\u003e 70kA @ 690V for maximum FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Controller Feature:\u003c\/strong\u003e SMB smart motor braking control – provides motor braking without additional equipment; braking current adjustable from 0–400% of motor full-load current rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Control Supply Voltage at DC:\u003c\/strong\u003e 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motor Overload Protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Protection Device Performance (SCPD) Type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Sensors (Max):\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Control Module:\u003c\/strong\u003e 5A @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = open), Max:\u003c\/strong\u003e 30V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Watts Control Module:\u003c\/strong\u003e 60 W @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Watts Control Module:\u003c\/strong\u003e 24 W @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = 4 kΩ), Max:\u003c\/strong\u003e \u0026lt;7.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 800 ms for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Time Control Module:\u003c\/strong\u003e 250 ms @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Time Control Module:\u003c\/strong\u003e 500 ms @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Resistance of PTC Sensor Chain (Max):\u003c\/strong\u003e 1500 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Input:\u003c\/strong\u003e 0–5V DC @ 4.5V DC = 100% Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllen Bradley Power Supply Control Module (Min):\u003c\/strong\u003e 1606-XLP50E @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Trip Resistance:\u003c\/strong\u003e 25 Ω ± 10 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Resistance:\u003c\/strong\u003e 3400 Ω ± 150 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Resistance:\u003c\/strong\u003e 1600 Ω ± 100 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Voltage (Max):\u003c\/strong\u003e 50V AC @ 10V DC\/12V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Voltage (Min):\u003c\/strong\u003e 85V AC @ 19.2V DC\/20.4V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current:\u003c\/strong\u003e 3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Current:\u003c\/strong\u003e 20mA @ 120V AC \/ 40mA @ 240V AC, 7.6mA @ 24V AC\/DC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3), and 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Heat Dissipation with Control and Fan Power:\u003c\/strong\u003e 91 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage and Transportation Temperature:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5–95% (noncondensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Open: -5 to 50 °C (23 to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Electrical Shock:\u003c\/strong\u003e IP2X (with terminal covers) per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Emission Levels:\u003c\/strong\u003e Radiated emission: Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity Levels:\u003c\/strong\u003e Surge transient: per EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 15 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Opsal: 5.5 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 196.4 mm (7.74 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 212.2 mm (8.35 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 443.7 mm (17.47 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Pole Construction:\u003c\/strong\u003e Heatsink hockey puck thyristor modular design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake:\u003c\/strong\u003e 3600VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreak:\u003c\/strong\u003e 360VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Bypass:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Single direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Terminal Markings:\u003c\/strong\u003e NEMA, CENELEC EN50 012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Terminals:\u003c\/strong\u003e Clamping yoke connection, M3 screw clamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine\/Load Side Power Terminals:\u003c\/strong\u003e One M10 x 1.5 diam hole per power pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Modules Construction:\u003c\/strong\u003e Thermoset and thermoplastic moldings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetal Parts Construction:\u003c\/strong\u003e Plated brass, copper, or painted steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Performance Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eOverload current for line connected devices:\u003c\/strong\u003e\u003c\/span\u003e 27 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eOverload current for delta connected devices:\u003c\/strong\u003e\u003c\/span\u003e 47 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eTrip classes:\u003c\/strong\u003e\u003c\/span\u003e 10, 15, 20, and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eTrip current rating:\u003c\/strong\u003e\u003c\/span\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #1976d2;\"\u003e\u003cstrong\u003eIntegrated motor overload protection:\u003c\/strong\u003e\u003c\/span\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #1976d2;\"\u003e\u003cstrong\u003eInternal bypass:\u003c\/strong\u003e\u003c\/span\u003e True\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F108NBRB?\u003c\/strong\u003e\u003cbr\u003eA: The controller handles 108 A for line connected motors and 47 A for delta connected motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which trip classes does this soft starter support?\u003c\/strong\u003e\u003cbr\u003eA: It supports trip classes 10, 15, 20, and 30.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The open-type controller operates from -5 to 50 °C (23 to 122 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this model include integrated motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003e150-F108NBRB\u003c\/strong\u003e includes integrated motor overload protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the rated control supply voltage?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 24 V AC at 50\/60 Hz and 24 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many auxiliary contacts does it provide?\u003c\/strong\u003e\u003cbr\u003eA: It provides one auxiliary contact with programmable NO\/NC configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support returns within 30 days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eWhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\" rel=\"noopener\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\" rel=\"noopener\" target=\"_blank\"\u003eNexAuto Technology Limited\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47173883035809,"sku":"150-F108NBRB","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F108NBRB.jpg?v=1789106179"},{"product_id":"150-f201nbrb-allen-bradley-smc-flex-soft-starter-201-a","title":"150-F201NBRB Allen-Bradley SMC Flex Soft Starter 201 A","description":"\u003ch2\u003e\u003cstrong\u003e150-F201NBRB SMC Flex Smart Motor Controller – 201 A Soft Starter by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F201NBRB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Soft Starter \/ Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 201 A, 75–150 Hp at 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage Ue:\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Control Supply Voltage:\u003c\/strong\u003e 24 V at 50 Hz and 60 Hz AC, 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current:\u003c\/strong\u003e 67 A for line connected devices, 116 A for delta connected devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Classes:\u003c\/strong\u003e 10, 15, 20 and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Current Rating:\u003c\/strong\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Power, Max:\u003c\/strong\u003e 75 Hp at 230V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Power, Max:\u003c\/strong\u003e 350 Hp at 575V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Current:\u003c\/strong\u003e 67–201 A at 600\/Y\/690V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Current:\u003c\/strong\u003e 116–348 A at 500\/575V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e Rated 500V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e 200–480V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Voltage:\u003c\/strong\u003e 6000V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Withstand:\u003c\/strong\u003e 2500V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT Protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive Peak Inverse Voltage:\u003c\/strong\u003e 1400V per UL\/CSA\/NEMA for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Metal oxide varistors 220 J (optional) for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection Device List:\u003c\/strong\u003e Standard fuse, circuit breaker and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity Available Fault Current, Max:\u003c\/strong\u003e 70 kA at 600V with 600 A time delay Class J or Class L fuse for inside delta connected motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Available Fault Current, Max:\u003c\/strong\u003e 70 kA at 690V for maximum FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motor Overload Protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Protection Device Performance (SCPD) Type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Sensors, Max:\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTC Input Ratings:\u003c\/strong\u003e Voltage at terminals max 30V (RPTC = open), max \u0026lt;7.5V (RPTC = 4 kΩ), response time 800 ms, cold resistance max 1500 Ω, short circuit trip resistance 25 Ω ± 10 Ω, response resistance 3400 Ω ± 150 Ω, reset resistance 1600 Ω ± 100 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Input:\u003c\/strong\u003e 0–5V DC at 4.5V DC = 100% Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Module Ratings:\u003c\/strong\u003e Inrush current 5A at 24V DC, transient watts 60 W at 24V DC, steady state watts 24 W at 24V DC, inrush time 250 ms at 24V DC, transient time 500 ms at 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e 1 contact, AC type, conventional thermal current 5 A, rated operational current 3A at 120V AC and 1.5A at 240V AC, make 3600VA, break 360VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3) and 33\/34 (Aux #4)\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F201NBRB?\u003c\/strong\u003e\u003cbr\u003eA: The controller rating is 201 A, and it supports 75–150 Hp at 460V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this soft starter include integrated motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the 150-F201NBRB includes integrated motor overload protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does this model require?\u003c\/strong\u003e\u003cbr\u003eA: It uses 24V AC\/DC for the control circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this controller for delta connected motors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports 116–348 A at 500\/575V AC for delta connected motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The open type unit operates from -5 to 50 °C (23 to 122 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the 150-F201NBRB in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we have it in stock and ship within 5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support 30-day returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this product new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47173933105313,"sku":"150-F201NBRB","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F201NBRB.jpg?v=1789106550"},{"product_id":"150-f625nbad-allen-bradley-smc-flex-motor-controller","title":"150-F625NBAD Allen-Bradley SMC Flex Motor Controller","description":"\u003ch2\u003e\u003cstrong\u003e150-F625NBAD SMC Flex Smart Motor Controller – 625 A Solid State Controller by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F625NBAD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Solid State Motor Controller \/ Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Bulletin 150, Solid State Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 625 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Power:\u003c\/strong\u003e 500 Hp at 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Voltage:\u003c\/strong\u003e 200–480V AC, 3-Phase, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 230–240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Type:\u003c\/strong\u003e Open\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Options:\u003c\/strong\u003e Braking Control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDescription:\u003c\/strong\u003e SMC Flex Smart Motor Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F625NBAD?\u003c\/strong\u003e\u003cbr\u003eA: The controller handles up to 625 A and supports 500 Hp at 460V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What input voltage does this controller accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 200–480V AC, 3-phase, 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does the 150-F625NBAD require?\u003c\/strong\u003e\u003cbr\u003eA: It uses 230–240V AC for the control circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this model include braking control?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the 150-F625NBAD includes braking control as a standard option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What enclosure type does this controller use?\u003c\/strong\u003e\u003cbr\u003eA: It uses an open enclosure type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the 150-F625NBAD in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we have it in stock and ship within 5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support 30-day returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this product new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47173992186017,"sku":"150-F625NBAD","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F625NBAD.jpg?v=1789107747"},{"product_id":"150-f625nbeb-allen-bradley-smart-motor-controller","title":"150-F625NBEB Allen-Bradley Smart Motor Controller","description":"\u003ch2\u003e\u003cstrong\u003e150-F625NBEB SMC Flex Open Smart Motor Controller – 625 A Soft Starter by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F625NBEB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Soft Starter \/ Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Bulletin 150, Solid State Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 625 A, 500 Hp at 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Voltage:\u003c\/strong\u003e 200–480V AC, 3-Phase, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 100–120V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage Ue:\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Control Supply Voltage:\u003c\/strong\u003e 110 V at 50 Hz and 60 Hz AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current:\u003c\/strong\u003e 208 A for line connected devices, 283 A for delta connected devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Classes:\u003c\/strong\u003e 10, 15, 20 and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Current Rating:\u003c\/strong\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Power, Max:\u003c\/strong\u003e 800 Hp at 600V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Power, Max:\u003c\/strong\u003e 900 Hp at 575V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Current:\u003c\/strong\u003e 208–625 A at 600\/Y\/690V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Current:\u003c\/strong\u003e 283–850 A at 500\/575V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e Rated 500V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e 200–480V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Voltage:\u003c\/strong\u003e 6000V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Withstand:\u003c\/strong\u003e 2500V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT Protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive Peak Inverse Voltage:\u003c\/strong\u003e 1400V per UL\/CSA\/NEMA for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Metal oxide varistors 220 J (optional) for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection Device List:\u003c\/strong\u003e Standard fuse, circuit breaker and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity Available Fault Current, Max:\u003c\/strong\u003e 74 kA at 600V with 1600 A time delay Class J or Class L fuse for line connected motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Available Fault Current, Max:\u003c\/strong\u003e 70 kA at 690V for maximum FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motor Overload Protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Protection Device Performance (SCPD) Type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Sensors, Max:\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTC Input Ratings:\u003c\/strong\u003e Voltage at terminals max 30V (RPTC = open), max \u0026lt;7.5V (RPTC = 4 kΩ), response time 800 ms, cold resistance max 1500 Ω, short circuit trip resistance 25 Ω ± 10 Ω, response resistance 3400 Ω ± 150 Ω, reset resistance 1600 Ω ± 100 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Input:\u003c\/strong\u003e 0–5V DC at 4.5V DC = 100% Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransformer Rating Control Module:\u003c\/strong\u003e 751 VA (recommended 800 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatsink Fan Rating:\u003c\/strong\u003e 150VA at 110\/120V AC or 220\/240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e 1 contact, AC type, conventional thermal current 5 A, rated operational current 3A at 120V AC and 1.5A at 240V AC, make 3600VA, break 360VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3) and 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Circuit:\u003c\/strong\u003e Electromagnetic relay for auxiliary contacts, programmable NO\/NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Current:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Voltage, Max:\u003c\/strong\u003e 50V AC at 10V DC\/12V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Voltage, Min:\u003c\/strong\u003e 85V AC at 19.2V DC\/20.4V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Current:\u003c\/strong\u003e 20mA at 120V AC, 40mA at 240V AC, 7.6mA at 24V AC\/DC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Heat Dissipation with Control and Fan Power:\u003c\/strong\u003e 446 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Open: -5 to 50 °C (23 to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage and Transportation Temperature:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5–95% (noncondensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Electrical Shock:\u003c\/strong\u003e IP00 (open device) per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Emission Levels:\u003c\/strong\u003e Radiated emission Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity Levels:\u003c\/strong\u003e Surge transient per EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Opsal 4 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Opsal 1.0 G peak, 0.15 mm (0.006 in) displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 179 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Width 596.9 mm (23.50 in), Depth 346.2 mm (13.63 in), Height 1041.1 mm (41 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F625NBEB?\u003c\/strong\u003e\u003cbr\u003eA: The controller rating is 625 A and it supports 500 Hp at 460V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What input voltage does this controller accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 200–480V AC, 3-phase, 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does the 150-F625NBEB require?\u003c\/strong\u003e\u003cbr\u003eA: It uses 100–120V AC for the control circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this model include pump control?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the 150-F625NBEB includes pump control as a standard option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this soft starter include integrated motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes integrated motor overload protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The open type unit operates from -5 to 50 °C (23 to 122 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the 150-F625NBEB in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we have it in stock and ship within 5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support 30-day returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this product new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47174008635553,"sku":"150-F625NBEB","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F625NBEB.jpg?v=1789108334"},{"product_id":"150-f1250nbab-allen-bradley-smc-flex-motor-controller","title":"150-F1250NBAB Allen-Bradley SMC-Flex Motor Controller","description":"\u003ch2\u003e\u003cstrong\u003e150-F1250NBAB Allen-Bradley SMC-Flex Smart Motor Controller – 1250 A Open Solid State Controller\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F1250NBAB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC-Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Solid State Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Bulletin 150\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 1250 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Power:\u003c\/strong\u003e 1000 Hp at 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Line Voltage:\u003c\/strong\u003e 200–480V AC, 3-Phase, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 230–240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Option:\u003c\/strong\u003e Pump Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the input voltage range for the 150-F1250NBAB?\u003c\/strong\u003e\u003cbr\u003eA: The controller accepts 200–480V AC, 3-phase, 50\/60 Hz input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does this SMC-Flex controller require?\u003c\/strong\u003e\u003cbr\u003eA: It requires a 230–240V AC control voltage supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of this Allen-Bradley controller?\u003c\/strong\u003e\u003cbr\u003eA: The 150-F1250NBAB has a 1250 A current rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this model include pump control?\u003c\/strong\u003e\u003cbr\u003eA: Yes, this unit comes with the Pump Control option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What motor size can this controller handle?\u003c\/strong\u003e\u003cbr\u003eA: It supports motors up to 1000 Hp at 460V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this controller new and in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we provide brand new original units and keep stock available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship this product?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 business days using FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the controller if it does not fit my application?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we accept returns within 30 days under our return policy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhone \/ WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47174052610209,"sku":"150-F1250NBAB","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F1250NBAB.jpg?v=1789108574"},{"product_id":"150-f625nbed-allen-bradley-smc-flex-625a-motor-controller","title":"150-F625NBED Allen-Bradley | SMC Flex 625A Motor Controller","description":"\u003ch2\u003e\u003cstrong\u003e150-F625NBED SMC Flex Smart Motor Controller – 625 A Soft Starter by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F625NBED\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Soft starter with internal bypass\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 625 A, 500 Hp @ 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage (Ue):\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e200...480V AC (-15%, +10%)\u003c\/strong\u003e\u003c\/span\u003e per UL\/CSA\/NEMA for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 100...120V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Control Supply Voltage:\u003c\/strong\u003e 110 V at both 50 Hz and 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current:\u003c\/strong\u003e 208 A for line connected devices; 283 A for delta connected devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Current:\u003c\/strong\u003e 208...625 A @ 600\/Y\/690V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Current:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e283...850 A @ 500\/575V AC, 3-phase\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Power, Max:\u003c\/strong\u003e 800 Hp @ 600V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Power, Max:\u003c\/strong\u003e 900 Hp @ 575V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Classes:\u003c\/strong\u003e 10, 15, 20 and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Current Rating:\u003c\/strong\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motor Overload Protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT Protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive Peak Inverse Voltage:\u003c\/strong\u003e 1400V per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Voltage:\u003c\/strong\u003e 6000V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Withstand:\u003c\/strong\u003e 2500V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e Rated 500V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Metal oxide varistors, 220 J (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection Device:\u003c\/strong\u003e Standard fuse, circuit breaker, and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity Available Fault Current, Max:\u003c\/strong\u003e 74 kA @ 600V with 1600 A time delay Class J or Class L fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Available Fault Current, Max:\u003c\/strong\u003e 70 kA @ 690V for maximum FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPD Type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilization Category:\u003c\/strong\u003e MG 1 per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControl and Monitoring Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Integrated display for easy setup and diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Options:\u003c\/strong\u003e Brake control available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Controller Feature:\u003c\/strong\u003e Status indication for stopped, starting, stopping, at speed, alarm, and fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Controller Feature:\u003c\/strong\u003e SMB smart motor braking control with adjustable braking current from 0...400% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Current:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Voltage, Max:\u003c\/strong\u003e 50V AC @ 10V DC\/12V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Voltage, Min:\u003c\/strong\u003e 85V AC @ 19.2V DC\/20.4V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Current:\u003c\/strong\u003e 20 mA @ 120V AC \/ 40 mA @ 240V AC, 7.6 mA @ 24V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Input:\u003c\/strong\u003e 0...5V DC @ 4.5V DC = 100% Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransformer Rating Control Module:\u003c\/strong\u003e 751 VA (recommended 800 VA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatsink Fan Rating:\u003c\/strong\u003e 150 VA @ 110\/120V AC or 220\/240V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAuxiliary Contacts and PTC Input Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Contacts:\u003c\/strong\u003e 1 for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Current:\u003c\/strong\u003e AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional Thermal Current (Ith):\u003c\/strong\u003e AC\/DC 5 A for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Control Circuit:\u003c\/strong\u003e Electromagnetic relay for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Contacts:\u003c\/strong\u003e Programmable NO\/NC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current:\u003c\/strong\u003e 3 A @ 120V AC, 1.5 A @ 240V AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3), and 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake:\u003c\/strong\u003e 3600 VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreak:\u003c\/strong\u003e 360 VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Sensors, Max:\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = open), Max:\u003c\/strong\u003e 30V for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = 4 kΩ), Max:\u003c\/strong\u003e \u0026lt;7.5V for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 800 ms for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Resistance of PTC Sensor Chain, Max:\u003c\/strong\u003e 1500 Ω for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Trip Resistance:\u003c\/strong\u003e 25 Ω ± 10 Ω for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e3400 Ω ± 150 Ω\u003c\/strong\u003e\u003c\/span\u003e for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Resistance:\u003c\/strong\u003e 1600 Ω ± 100 Ω for PTC input ratings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Physical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Heat Dissipation:\u003c\/strong\u003e 446 W with control and fan power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage and Transportation Temperature:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5...95% (noncondensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Open: -5 to 50 °C (23 to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Electrical Shock:\u003c\/strong\u003e IP00 (open device) per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Emission Levels:\u003c\/strong\u003e Radiated emission Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity Levels:\u003c\/strong\u003e Surge transient per EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Opsal 4 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Opsal 1.0 G peak, 0.15 mm (0.006 in) displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 179 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 596.9 mm (23.50 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 346.2 mm (13.63 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 1041.1 mm (41 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction and Terminal Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Pole Construction:\u003c\/strong\u003e Heatsink hockey puck thyristor modular design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Single direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Bypass:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Terminal Markings:\u003c\/strong\u003e NEMA, CENELEC EN50 012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Terminals:\u003c\/strong\u003e Clamping yoke connection, M3 screw clamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine\/Load Side Power Terminals:\u003c\/strong\u003e Two 13.5 mm (0.53 in) diam holes per power pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Modules Construction:\u003c\/strong\u003e Thermoset and thermoplastic moldings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetal Parts Construction:\u003c\/strong\u003e Plated brass, copper, or painted steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the controller rating of the 150-F625NBED?\u003c\/strong\u003e\u003cbr\u003eA: It rates 625 A and 500 Hp at 460V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which trip classes does this soft starter support?\u003c\/strong\u003e\u003cbr\u003eA: It supports trip classes 10, 15, 20, and 30.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The open device operates from -5 to 50 °C (23 to 122 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it include integrated motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, integrated motor overload protection is available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum altitude for installation?\u003c\/strong\u003e\u003cbr\u003eA: The maximum altitude is 2000 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many PTC sensors can I connect?\u003c\/strong\u003e\u003cbr\u003eA: You can connect up to 6 sensors for PTC input ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does delivery take?\u003c\/strong\u003e\u003cbr\u003eA: We dispatch within 5 days and delivery time depends on your location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we accept returns within 30 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the product new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, all products are brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e, \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47174095896737,"sku":"150-F625NBED","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F625NBED.jpg?v=1789108800"},{"product_id":"150-f43nbrb-allen-bradley-smart-motor-controller-24v-ac-dc","title":"150-F43NBRB Allen-Bradley Smart Motor Controller 24V AC\/DC","description":"\u003ch2\u003e\u003cstrong\u003e150-F43NBRB SMC Flex Smart Motor Controller – 43 A Soft Starter by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F43NBRB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Soft starter with internal bypass\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 43 A, 7.5-30.0 Hp @ 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage (Ue):\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e200...480V AC (-15%, +10%)\u003c\/strong\u003e\u003c\/span\u003e per UL\/CSA\/NEMA for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Control Supply Voltage:\u003c\/strong\u003e 24 V at 50 Hz, 60 Hz, and DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Type for Actuating:\u003c\/strong\u003e AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current:\u003c\/strong\u003e 8.6 A for line connected devices; 14.8 A for delta connected devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Current:\u003c\/strong\u003e 8.6...43 A @ 500\/575V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Current:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e14.9...74 A @ 500\/575V AC, 3-phase\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Power, Max:\u003c\/strong\u003e 40 Hp @ 575V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Power, Max:\u003c\/strong\u003e 60 Hp @ 575V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Classes:\u003c\/strong\u003e 10, 15, 20 and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Current Rating:\u003c\/strong\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motor Overload Protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT Protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive Peak Inverse Voltage:\u003c\/strong\u003e 1400V per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Voltage:\u003c\/strong\u003e 6000V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Withstand:\u003c\/strong\u003e 2500V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e Rated 500V per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Metal oxide varistors, 220 J (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection Device:\u003c\/strong\u003e Standard fuse, circuit breaker, and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity Available Fault Current, Max:\u003c\/strong\u003e 70 kA @ 600V with 90 A time delay Class J or Class L fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Available Fault Current, Max:\u003c\/strong\u003e 10 kA @ 200...600V with maximum standard fuse 300 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPD Type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilization Category:\u003c\/strong\u003e MG 1 per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControl and Monitoring Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Integrated display for easy setup and diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Options:\u003c\/strong\u003e Pump control available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Controller Feature:\u003c\/strong\u003e Status indication for stopped, starting, stopping, at speed, alarm, and fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Controller Feature:\u003c\/strong\u003e SMB smart motor braking control with adjustable braking current from 0...400% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Current:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Voltage, Max:\u003c\/strong\u003e 50V AC @ 10V DC\/12V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Voltage, Min:\u003c\/strong\u003e 85V AC @ 19.2V DC\/20.4V AC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Current:\u003c\/strong\u003e 20 mA @ 120V AC \/ 40 mA @ 240V AC, 7.6 mA @ 24V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Input:\u003c\/strong\u003e 0...5V DC @ 4.5V DC = 100% Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransformer Control Module:\u003c\/strong\u003e 75 VA @ 100...240V AC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatsink Fan Rating:\u003c\/strong\u003e 20 VA @ 110\/120V AC or 220\/240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Control Module:\u003c\/strong\u003e 5 A @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Watts Control Module:\u003c\/strong\u003e 60 W @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Watts Control Module:\u003c\/strong\u003e 24 W @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Time Control Module:\u003c\/strong\u003e 250 ms @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Time Control Module:\u003c\/strong\u003e 500 ms @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Control Module, Min:\u003c\/strong\u003e 1606-XLP50E @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAuxiliary Contacts and PTC Input Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Contacts:\u003c\/strong\u003e 1 for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Current:\u003c\/strong\u003e AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional Thermal Current (Ith):\u003c\/strong\u003e AC\/DC 5 A for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Control Circuit:\u003c\/strong\u003e Electromagnetic relay for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Contacts:\u003c\/strong\u003e Programmable NO\/NC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current:\u003c\/strong\u003e 3 A @ 120V AC, 1.5 A @ 240V AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3), and 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake:\u003c\/strong\u003e 3600 VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreak:\u003c\/strong\u003e 360 VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Sensors, Max:\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = open), Max:\u003c\/strong\u003e 30V for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = 4 kΩ), Max:\u003c\/strong\u003e \u0026lt;7.5V for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 800 ms for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Resistance of PTC Sensor Chain, Max:\u003c\/strong\u003e 1500 Ω for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Trip Resistance:\u003c\/strong\u003e 25 Ω ± 10 Ω for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e3400 Ω ± 150 Ω\u003c\/strong\u003e\u003c\/span\u003e for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Resistance:\u003c\/strong\u003e 1600 Ω ± 100 Ω for PTC input ratings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Physical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Heat Dissipation:\u003c\/strong\u003e 81 W with control and fan power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage and Transportation Temperature:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5...95% (noncondensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Open: -5 to 50 °C (23 to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Electrical Shock:\u003c\/strong\u003e IP20 per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Emission Levels:\u003c\/strong\u003e Radiated emission Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity Levels:\u003c\/strong\u003e Surge transient per EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Opsal 15 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Opsal 1.0 G peak, 0.15 mm (0.006 in) displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.7 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 150 mm (5.90 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 203 mm (8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 321 mm (12.60 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction and Terminal Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Pole Construction:\u003c\/strong\u003e Heatsink thyristor modular design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Single direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Bypass:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Terminal Markings:\u003c\/strong\u003e NEMA, CENELEC EN50 012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Terminals:\u003c\/strong\u003e Clamping yoke connection, M3 screw clamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Line Side Cable Size:\u003c\/strong\u003e 0.8...2.5 mm² (18...14 AWG)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Load Side Cable Size:\u003c\/strong\u003e 0.8...2.5 mm² (18...14 AWG)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpper Load Side Cable Size:\u003c\/strong\u003e 2.5...50 mm² (14...1 AWG)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpper Line Side Cable Size:\u003c\/strong\u003e 2.5...95 mm² (14...3 AWG)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 14.7 Nm (130 in-lb) for power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Strip Length:\u003c\/strong\u003e 18...20 mm (0.22...0.34 in) for power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Modules Construction:\u003c\/strong\u003e Thermoset and thermoplastic moldings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetal Parts Construction:\u003c\/strong\u003e Plated brass, copper, or painted steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller vertically on a flat, rigid surface inside a suitable enclosure.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum clearance around the heatsink to allow proper airflow and cooling.\u003c\/li\u003e\n\u003cli\u003eConnect line and load power terminals using the specified cable sizes for each side.\u003c\/li\u003e\n\u003cli\u003eUse M3 screw clamps for all control terminal wiring connections.\u003c\/li\u003e\n\u003cli\u003eVerify control voltage stays within 24V AC\/DC before applying power.\u003c\/li\u003e\n\u003cli\u003eCheck the input OFF-state current stays below 10 mA AC for safe operation.\u003c\/li\u003e\n\u003cli\u003eInstall Class J or Class L time delay fuses for short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eConfirm the operating frequency matches 50\/60 Hz for the power circuit.\u003c\/li\u003e\n\u003cli\u003eTest the display for status indication before full load startup.\u003c\/li\u003e\n\u003cli\u003eKeep the pollution degree at 2 and altitude below 2000 m.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePacking List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003e150-F43NBRB\u003c\/strong\u003e SMC Flex Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e1 x Integrated display module\u003c\/li\u003e\n\u003cli\u003e1 x Heatsink fan assembly\u003c\/li\u003e\n\u003cli\u003e1 x Internal bypass module\u003c\/li\u003e\n\u003cli\u003e1 x Set of M3 screw clamps for control terminals\u003c\/li\u003e\n\u003cli\u003e1 x Installation instruction sheet\u003c\/li\u003e\n\u003cli\u003e1 x Protective packing foam and carton\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship worldwide via FedEx, UPS, and DHL for fast and reliable delivery.\u003c\/li\u003e\n\u003cli\u003eWe dispatch all orders within 5 days after payment confirmation.\u003c\/li\u003e\n\u003cli\u003eWe offer 30-day return policy for eligible products.\u003c\/li\u003e\n\u003cli\u003eAll items are brand new and original from the manufacturer.\u003c\/li\u003e\n\u003cli\u003eWe keep sufficient stock for immediate order processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the controller rating of the 150-F43NBRB?\u003c\/strong\u003e\u003cbr\u003eA: It rates 43 A and 7.5-30.0 Hp at 460V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does this soft starter use?\u003c\/strong\u003e\u003cbr\u003eA: It uses 24V AC\/DC control voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which trip classes does this soft starter support?\u003c\/strong\u003e\u003cbr\u003eA: It supports trip classes 10, 15, 20, and 30.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The open device operates from -5 to 50 °C (23 to 122 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it include integrated motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, integrated motor overload protection is available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum altitude for installation?\u003c\/strong\u003e\u003cbr\u003eA: The maximum altitude is 2000 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many PTC sensors can I connect?\u003c\/strong\u003e\u003cbr\u003eA: You can connect up to 6 sensors for PTC input ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does delivery take?\u003c\/strong\u003e\u003cbr\u003eA: We dispatch within 5 days and delivery time depends on your location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we accept returns within 30 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the product new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, all products are brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e, \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47174212190369,"sku":"150-F43NBRB","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F43NBRB.jpg?v=1789109424"},{"product_id":"150-f43nbrd-allen-bradley-smc-flex-soft-starter-43a","title":"150-F43NBRD Allen-Bradley SMC Flex Soft Starter 43A","description":"\u003ch2\u003e\u003cstrong\u003e150-F43NBRD Allen-Bradley SMC Flex Smart Motor Controller – 43 A Soft Starter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F43NBRD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController type:\u003c\/strong\u003e Soft starter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController rating:\u003c\/strong\u003e 43 A, 7.5–30.0 Hp @ 460 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl voltage:\u003c\/strong\u003e 24 V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operating voltage Ue:\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated control supply voltage:\u003c\/strong\u003e 24 V at 50 Hz and 60 Hz AC, plus 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload current (line connected):\u003c\/strong\u003e 8.6 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload current (delta connected):\u003c\/strong\u003e 14.8 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 200–480 V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation voltage:\u003c\/strong\u003e Rated 500 V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated impulse voltage:\u003c\/strong\u003e 6000 V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric withstand:\u003c\/strong\u003e 2500 V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive peak inverse voltage:\u003c\/strong\u003e 1400 V per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient protection:\u003c\/strong\u003e Metal oxide varistors, 220 J (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-state current:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-state voltage, max:\u003c\/strong\u003e 50 V AC @ 10 V DC \/ 12 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-state voltage, min:\u003c\/strong\u003e 85 V AC @ 19.2 V DC \/ 20.4 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-state current:\u003c\/strong\u003e 20 mA @ 120 V AC, 40 mA @ 240 V AC, 7.6 mA @ 24 V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit protection device list:\u003c\/strong\u003e Standard fuse, circuit breaker, and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh capacity available fault current, max:\u003c\/strong\u003e 70 kA @ 600 V with 90 A time delay Class J or L fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard available fault current, max:\u003c\/strong\u003e 10 kA @ 200–600 V with 300 A standard fuse\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMotor Power and Current Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine connected motor power, max:\u003c\/strong\u003e 40 Hp @ 575 V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta connected motor power, max:\u003c\/strong\u003e 60 Hp @ 575 V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine connected motor current:\u003c\/strong\u003e 8.6–43 A @ 500\/575 V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta connected motor current:\u003c\/strong\u003e 14.9–74 A @ 500\/575 V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Single direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal bypass:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower pole construction:\u003c\/strong\u003e Heatsink thyristor modular design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControl, Protection, and Display Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Integrated, true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip classes:\u003c\/strong\u003e 10, 15, 20, and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip current rating:\u003c\/strong\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated motor overload protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit protection device performance (SCPD) type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard controller feature:\u003c\/strong\u003e Status indication for stopped, starting, stopping, at speed, alarm, and fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional controller feature:\u003c\/strong\u003e SMB smart motor braking control with adjustable braking current from 0–400% of motor full-load current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Brake control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransformer control module:\u003c\/strong\u003e 75 VA @ 100–240 V AC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatsink fan rating:\u003c\/strong\u003e 20 VA @ 110\/120 V AC or 220\/240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush current control module:\u003c\/strong\u003e 5 A @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient watts control module:\u003c\/strong\u003e 60 W @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady state watts control module:\u003c\/strong\u003e 24 W @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush time control module:\u003c\/strong\u003e 250 ms @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient time control module:\u003c\/strong\u003e 500 ms @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllen-Bradley power supply control module, min:\u003c\/strong\u003e 1606-XLP50E @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady state heat dissipation with control and fan power:\u003c\/strong\u003e 81 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePTC Input and Tachometer Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of sensors, max:\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC terminals (RPTC = open), max:\u003c\/strong\u003e 30 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC terminals (RPTC = 4 kΩ), max:\u003c\/strong\u003e \u0026lt;7.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e 800 ms for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold resistance of PTC sensor chain, max:\u003c\/strong\u003e 1500 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit trip resistance:\u003c\/strong\u003e 25 Ω ± 10 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse resistance:\u003c\/strong\u003e 3400 Ω ± 150 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset resistance:\u003c\/strong\u003e 1600 Ω ± 100 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer input:\u003c\/strong\u003e 0–5 V DC @ 4.5 V DC = 100% speed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAuxiliary Contacts and Control Circuit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of contacts:\u003c\/strong\u003e 1 for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of current:\u003c\/strong\u003e AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional thermal current (Ith):\u003c\/strong\u003e AC\/DC 5 A for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of control circuit:\u003c\/strong\u003e Electromagnetic relay for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of contacts:\u003c\/strong\u003e Programmable NO\/NC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational current:\u003c\/strong\u003e 3 A @ 120 V AC, 1.5 A @ 240 V AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3), and 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake:\u003c\/strong\u003e 3600 VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreak:\u003c\/strong\u003e 360 VA for auxiliary contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Wiring Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower line side cable size:\u003c\/strong\u003e 0.8–2.5 mm² (18–14 AWG) for power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower load side cable size:\u003c\/strong\u003e 0.8–2.5 mm² (18–14 AWG) for power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpper load side cable size:\u003c\/strong\u003e 2.5–50 mm² (14–1 AWG) for load power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpper line side cable size:\u003c\/strong\u003e 2.5–95 mm² (14–3 AWG) for line power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening torque:\u003c\/strong\u003e 14.7 Nm (130 in-lb) for power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire strip length:\u003c\/strong\u003e 18–20 mm (0.22–0.34 in) for power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower terminal markings:\u003c\/strong\u003e NEMA, CENELEC EN50 012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl terminals:\u003c\/strong\u003e Clamping yoke connection, M3 screw clamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl modules construction:\u003c\/strong\u003e Thermoset and thermoplastic moldings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetal parts construction:\u003c\/strong\u003e Plated brass, copper, or painted steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection against electrical shock:\u003c\/strong\u003e IP20 per IEC for power circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Physical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e Open -5 to 50 °C (23 to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage and transportation temperature:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5–95% (noncondensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission levels:\u003c\/strong\u003e Radiated emission Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity levels:\u003c\/strong\u003e Surge transient per EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Operational 15 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Operational 1.0 G peak, 0.15 mm (0.006 in) displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.7 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 150 mm (5.90 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 203 mm (8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 321 mm (12.60 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley \u003cstrong\u003e150-F43NBRD\u003c\/strong\u003e SMC Flex Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e1 x Integrated display module\u003c\/li\u003e\n\u003cli\u003e1 x Installation and wiring guide\u003c\/li\u003e\n\u003cli\u003e1 x Accessory terminal set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship worldwide via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eWe dispatch orders within 5 days after payment confirmation.\u003c\/li\u003e\n\u003cli\u003eWe offer a 30-day return policy for eligible items.\u003c\/li\u003e\n\u003cli\u003eAll products are brand new and original.\u003c\/li\u003e\n\u003cli\u003eWe keep most items in stock for immediate fulfillment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the control voltage for the 150-F43NBRD?\u003c\/strong\u003e\u003cbr\u003eA: The controller accepts 24 V AC\/DC control voltage at 50 Hz and 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this soft starter include built-in motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it integrates motor overload protection and supports trip classes 10, 15, 20, and 30.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum line connected motor power at 575 V AC?\u003c\/strong\u003e\u003cbr\u003eA: It supports up to 40 Hp for line connected motors at 575 V AC, 60 Hz, 3-phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use the 150-F43NBRD for delta connected motors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it handles up to 60 Hp and 14.9–74 A for delta connected motors at 500\/575 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS, and DHL, and we dispatch within 5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We accept returns within 30 days for eligible products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47628853641377,"sku":"150-F43NBRD","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F43NBRD.jpg?v=1789703054"},{"product_id":"150-f251nbrb-allen-bradley-smc-flex-soft-starter-251a","title":"150-F251NBRB Allen-Bradley SMC Flex Soft Starter 251A","description":"\u003ch2\u003e\u003cstrong\u003e150-F251NBRB Allen-Bradley SMC Flex Smart Motor Controller – 251 A Soft Starter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F251NBRB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController type:\u003c\/strong\u003e Soft starter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController rating:\u003c\/strong\u003e 251 A, 100–200 Hp @ 460 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl voltage:\u003c\/strong\u003e 24 V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operating voltage Ue:\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated control supply voltage:\u003c\/strong\u003e 24 V at 50 Hz and 60 Hz AC, plus 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload current (line connected):\u003c\/strong\u003e 84 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload current (delta connected):\u003c\/strong\u003e 145 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 200–480 V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation voltage:\u003c\/strong\u003e Rated 500 V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated impulse voltage:\u003c\/strong\u003e 6000 V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric withstand:\u003c\/strong\u003e 2500 V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive peak inverse voltage:\u003c\/strong\u003e 1400 V per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient protection:\u003c\/strong\u003e Metal oxide varistors, 220 J (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-state current:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC for control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-state voltage, max:\u003c\/strong\u003e 50 V AC @ 10 V DC \/ 12 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-state voltage, min:\u003c\/strong\u003e 85 V AC @ 19.2 V DC \/ 20.4 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-state current:\u003c\/strong\u003e 20 mA @ 120 V AC, 40 mA @ 240 V AC, 7.6 mA @ 24 V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit protection device list:\u003c\/strong\u003e Standard fuse, circuit breaker, and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh capacity available fault current, max:\u003c\/strong\u003e 70 kA @ 600 V with 800 A time delay Class J or L fuse for inside delta connected motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard available fault current, max:\u003c\/strong\u003e 70 kA @ 690 V for maximum FLC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMotor Power and Current Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine connected motor power, max:\u003c\/strong\u003e 75 kW @ 230 V AC, 50 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta connected motor power, max:\u003c\/strong\u003e 400 Hp @ 575 V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine connected motor current:\u003c\/strong\u003e 84–251 A @ 600\/Y\/690 V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta connected motor current:\u003c\/strong\u003e 145–435 A @ 500\/575 V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpere tested European style, max:\u003c\/strong\u003e 6.9 gRB 73xxx630, 6.6URD33xxx700 @ 690 V for maximum FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpere tested North American style, max:\u003c\/strong\u003e A070URD33xxx700 @ 690 V for maximum FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Single direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal bypass:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower pole construction:\u003c\/strong\u003e Heatsink hockey puck thyristor modular design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControl, Protection, and Display Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Integrated, true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Pump control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip classes:\u003c\/strong\u003e 10, 15, 20, and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip current rating:\u003c\/strong\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated motor overload protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit protection device performance (SCPD) type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard controller feature:\u003c\/strong\u003e Status indication for stopped, starting, stopping, at speed, alarm, and fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional controller feature:\u003c\/strong\u003e SMB smart motor braking control with adjustable braking current from 0–400% of motor full-load current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransformer control module:\u003c\/strong\u003e 75 VA @ 100–240 V AC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatsink fan rating:\u003c\/strong\u003e 40 VA @ 110\/120 V AC or 220\/240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush current control module:\u003c\/strong\u003e 5 A @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient watts control module:\u003c\/strong\u003e 60 W @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady state watts control module:\u003c\/strong\u003e 24 W @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush time control module:\u003c\/strong\u003e 250 ms @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient time control module:\u003c\/strong\u003e 500 ms @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllen-Bradley power supply control module, min:\u003c\/strong\u003e 1606-XLP50E @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady state heat dissipation with control and fan power:\u003c\/strong\u003e 198 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePTC Input and Tachometer Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of sensors, max:\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC terminals (RPTC = open), max:\u003c\/strong\u003e 30 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC terminals (RPTC = 4 kΩ), max:\u003c\/strong\u003e \u0026lt;7.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e 800 ms for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold resistance of PTC sensor chain, max:\u003c\/strong\u003e 1500 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit trip resistance:\u003c\/strong\u003e 25 Ω ± 10 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse resistance:\u003c\/strong\u003e 3400 Ω ± 150 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset resistance:\u003c\/strong\u003e 1600 Ω ± 100 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer input:\u003c\/strong\u003e 0–5 V DC @ 4.5 V DC = 100% speed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAuxiliary Contacts and Control Circuit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of contacts:\u003c\/strong\u003e 1 for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of current:\u003c\/strong\u003e AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional thermal current (Ith):\u003c\/strong\u003e AC\/DC 5 A for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of control circuit:\u003c\/strong\u003e Electromagnetic relay for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of contacts:\u003c\/strong\u003e Programmable NO\/NC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational current:\u003c\/strong\u003e 3 A @ 120 V AC, 1.5 A @ 240 V AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3), and 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake:\u003c\/strong\u003e 3600 VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreak:\u003c\/strong\u003e 360 VA for auxiliary contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Wiring Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine\/load side power terminals:\u003c\/strong\u003e Two M10 x 1.5 diameter holes per power pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower terminal markings:\u003c\/strong\u003e NEMA, CENELEC EN50 012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl terminals:\u003c\/strong\u003e Clamping yoke connection, M3 screw clamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection against electrical shock:\u003c\/strong\u003e IP2X (with terminal covers) per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl modules construction:\u003c\/strong\u003e Thermoset and thermoplastic moldings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetal parts construction:\u003c\/strong\u003e Plated brass, copper, or painted steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Physical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e Open -5 to 50 °C (23 to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage and transportation temperature:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5–95% (noncondensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission levels:\u003c\/strong\u003e Radiated emission Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity levels:\u003c\/strong\u003e Surge transient per EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Operational 5.5 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Operational 1.0 G peak, 0.15 mm (0.006 in) displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 30.4 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 225 mm (8.86 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 253.8 mm (9.99 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 560 mm (22.05 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley \u003cstrong\u003e150-F251NBRB\u003c\/strong\u003e SMC Flex Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e1 x Integrated display module\u003c\/li\u003e\n\u003cli\u003e1 x Installation and wiring guide\u003c\/li\u003e\n\u003cli\u003e1 x Accessory terminal set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship worldwide via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eWe dispatch orders within 5 days after payment confirmation.\u003c\/li\u003e\n\u003cli\u003eWe offer a 30-day return policy for eligible items.\u003c\/li\u003e\n\u003cli\u003eAll products are brand new and original.\u003c\/li\u003e\n\u003cli\u003eWe keep most items in stock for immediate fulfillment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the controller rating of the 150-F251NBRB?\u003c\/strong\u003e\u003cbr\u003eA: It handles 251 A and 100–200 Hp at 460 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does this soft starter accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 24 V AC\/DC at both 50 Hz and 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the 150-F251NBRB include pump control?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it offers pump control as a built-in control option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum delta connected motor power at 575 V AC?\u003c\/strong\u003e\u003cbr\u003eA: It supports up to 400 Hp for delta connected motors at 575 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS, and DHL, and we dispatch within 5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We accept returns within 30 days for eligible products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47629200359585,"sku":"150-F251NBRB","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F251NBRB.jpg?v=1789703375"},{"product_id":"150-f780nbad-allen-bradley-soft-starter-780a-600hp","title":"150-F780NBAD Allen-Bradley Soft Starter 780A 600Hp","description":"\u003ch2\u003e\u003cstrong\u003e150-F780NBAD Allen-Bradley SMC Flex Solid State Motor Controller – 780 A Soft Starter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F780NBAD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController type:\u003c\/strong\u003e Solid state controller \/ Soft starter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController rating:\u003c\/strong\u003e 780 A, 600 Hp @ 460 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput voltage:\u003c\/strong\u003e 200–480 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl voltage:\u003c\/strong\u003e 230–240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Braking control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh current capacity:\u003c\/strong\u003e 780 A for large motor starting applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower rating:\u003c\/strong\u003e Up to 600 Hp at 460 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input voltage range:\u003c\/strong\u003e 200–480 V AC for flexible installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl voltage:\u003c\/strong\u003e 230–240 V AC for reliable operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBraking control option:\u003c\/strong\u003e Provides motor braking without additional equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen enclosure:\u003c\/strong\u003e Designed for panel or cabinet mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid state design:\u003c\/strong\u003e SCR-based power control for smooth motor starting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSMC Flex platform:\u003c\/strong\u003e Proven Allen-Bradley technology for motor protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge industrial motors requiring soft starting\u003c\/li\u003e\n\u003cli\u003ePumps, fans, and compressors with high inertia loads\u003c\/li\u003e\n\u003cli\u003eConveyors and crushers in mining and aggregates\u003c\/li\u003e\n\u003cli\u003eProcess equipment in water treatment and chemical plants\u003c\/li\u003e\n\u003cli\u003eAny application needing reduced mechanical stress during startup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley \u003cstrong\u003e150-F780NBAD\u003c\/strong\u003e SMC Flex Solid State Motor Controller\u003c\/li\u003e\n\u003cli\u003e1 x Installation and wiring guide\u003c\/li\u003e\n\u003cli\u003e1 x Accessory terminal set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship worldwide via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eWe dispatch orders within 5 days after payment confirmation.\u003c\/li\u003e\n\u003cli\u003eWe offer a 30-day return policy for eligible items.\u003c\/li\u003e\n\u003cli\u003eAll products are brand new and original.\u003c\/li\u003e\n\u003cli\u003eWe keep most items in stock for immediate fulfillment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F780NBAD?\u003c\/strong\u003e\u003cbr\u003eA: It handles 780 A and supports up to 600 Hp at 460 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the input voltage range for this controller?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 200–480 V AC input voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does the 150-F780NBAD require?\u003c\/strong\u003e\u003cbr\u003eA: It operates with 230–240 V AC control voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this controller include braking control?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it comes with a braking control option for fast motor stopping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What enclosure type does this controller use?\u003c\/strong\u003e\u003cbr\u003eA: It uses an open type enclosure for panel or cabinet mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS, and DHL, and we dispatch within 5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We accept returns within 30 days for eligible products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47629477019809,"sku":"150-F780NBAD","price":248.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F780NBAD.jpg?v=1789703536"},{"product_id":"150-f251nbrd-allen-bradley-smc-flex-soft-starter","title":"150-F251NBRD Allen-Bradley SMC Flex Soft Starter","description":"\u003ch2\u003e\u003cstrong\u003e150-F251NBRD SMC Flex Smart Motor Controller – 251 A Soft Starter by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F251NBRD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController type:\u003c\/strong\u003e Soft starter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController rating:\u003c\/strong\u003e 251 A, 100–200 Hp @ 460 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl voltage:\u003c\/strong\u003e 24 V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operating voltage Ue:\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine connected motor current:\u003c\/strong\u003e 84–251 A @ 600\/Y\/690 V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta connected motor current:\u003c\/strong\u003e 145–435 A @ 500\/575 V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload current (line):\u003c\/strong\u003e 84 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload current (delta):\u003c\/strong\u003e 145 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip current rating:\u003c\/strong\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip classes:\u003c\/strong\u003e 10, 15, 20 and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated impulse voltage:\u003c\/strong\u003e 6000 V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric withstand:\u003c\/strong\u003e 2500 V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation voltage:\u003c\/strong\u003e Rated 500 V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational voltage:\u003c\/strong\u003e 200–480 V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive peak inverse voltage:\u003c\/strong\u003e 1400 V per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient protection:\u003c\/strong\u003e Metal oxide varistors, 220 J (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit protection device list:\u003c\/strong\u003e Standard fuse, circuit breaker, and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh capacity available fault current:\u003c\/strong\u003e 70 kA @ 600 V, max 800 A time delay Class J or L fuse for inside delta motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard available fault current:\u003c\/strong\u003e 70 kA @ 690 V for maximum FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated motor overload protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal bypass:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Single direction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControl and Monitoring Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWith display:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Brake control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard controller feature:\u003c\/strong\u003e Status indication – stopped, starting, stopping, at speed, alarm, and fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional controller feature:\u003c\/strong\u003e SMB smart motor braking control – provides motor braking without extra equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBraking current:\u003c\/strong\u003e Adjustable from 0–400% of motor full-load current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of sensors:\u003c\/strong\u003e Max 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC terminals (RPTC = open):\u003c\/strong\u003e Max 30 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC terminals (RPTC = 4 kΩ):\u003c\/strong\u003e Max \u0026lt;7.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e 800 ms for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold resistance of PTC sensor chain:\u003c\/strong\u003e Max 1500 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit trip resistance:\u003c\/strong\u003e 25 Ω ± 10 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse resistance:\u003c\/strong\u003e 3400 Ω ± 150 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset resistance:\u003c\/strong\u003e 1600 Ω ± 100 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer input:\u003c\/strong\u003e 0–5 V DC, 4.5 V DC = 100% speed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAuxiliary Contacts and Control Circuit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of contacts:\u003c\/strong\u003e 1 for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of current:\u003c\/strong\u003e AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional thermal current (Ith):\u003c\/strong\u003e AC\/DC 5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of control circuit:\u003c\/strong\u003e Electromagnetic relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of contacts:\u003c\/strong\u003e Programmable NO\/NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated operational current:\u003c\/strong\u003e 3 A @ 120 V AC, 1.5 A @ 240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-state current:\u003c\/strong\u003e 20 mA @ 120 V AC \/ 40 mA @ 240 V AC, 7.6 mA @ 24 V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-state current:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-state voltage, max:\u003c\/strong\u003e 50 V AC @ 10 V DC \/ 12 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-state voltage, min:\u003c\/strong\u003e 85 V AC @ 19.2 V DC \/ 20.4 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3), 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake:\u003c\/strong\u003e 3600 VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreak:\u003c\/strong\u003e 360 VA for auxiliary contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and Control Module Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransformer control module:\u003c\/strong\u003e 75 VA @ 100–240 V AC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatsink fan rating:\u003c\/strong\u003e 40 VA @ 110\/120 V AC or 220\/240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush current control module:\u003c\/strong\u003e 5 A @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient watts control module:\u003c\/strong\u003e 60 W @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady state watts control module:\u003c\/strong\u003e 24 W @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush time control module:\u003c\/strong\u003e 250 ms @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient time control module:\u003c\/strong\u003e 500 ms @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllen-Bradley power supply control module, min:\u003c\/strong\u003e 1606-XLP50E @ 24 V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated control supply voltage at AC 50 Hz:\u003c\/strong\u003e 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated control supply voltage at AC 60 Hz:\u003c\/strong\u003e 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated control supply voltage at DC:\u003c\/strong\u003e 24 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Mechanical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady state heat dissipation with control and fan power:\u003c\/strong\u003e 198 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage and transportation temperature:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5–95% (noncondensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e Open: -5 to 50 °C (23 to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection against electrical shock:\u003c\/strong\u003e IP2X (with terminal covers) per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC emission levels:\u003c\/strong\u003e Radiated emission – Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC immunity levels:\u003c\/strong\u003e Surge transient per EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Opsal 5.5 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Opsal 1.0 G peak, 0.15 mm displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 30.4 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 225 mm (8.86 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 253.8 mm (9.99 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 560 mm (22.05 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower pole construction:\u003c\/strong\u003e Heatsink hockey puck thyristor modular design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl modules construction:\u003c\/strong\u003e Thermoset and thermoplastic moldings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetal parts construction:\u003c\/strong\u003e Plated brass, copper, or painted steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminals and Wiring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower terminal markings:\u003c\/strong\u003e NEMA, CENELEC EN50 012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl terminals:\u003c\/strong\u003e Clamping yoke connection, M3 screw clamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine\/load side power terminals:\u003c\/strong\u003e Two M10 x 1.5 diam holes per power pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpere tested European style, max:\u003c\/strong\u003e 6.9 gRB 73xxx630, 6.6 URD33xxx700 @ 690 V for maximum FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpere tested North American style, max:\u003c\/strong\u003e A070URD33xxx700 @ 690 V for maximum FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit protection device performance (SCPD) type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilization category:\u003c\/strong\u003e MG 1 per UL\/CSA\/NEMA for power circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller vertically on a flat, vibration-free surface inside an enclosure.\u003c\/li\u003e\n\u003cli\u003eKeep a minimum clearance of 100 mm above and below the heatsink for airflow.\u003c\/li\u003e\n\u003cli\u003eConnect line and load power cables to the M10 terminals with proper torque.\u003c\/li\u003e\n\u003cli\u003eUse Class J or L time-delay fuses for short-circuit protection as recommended.\u003c\/li\u003e\n\u003cli\u003eWire the 24 V AC\/DC control circuit to the clamping yoke terminals with M3 screws.\u003c\/li\u003e\n\u003cli\u003eVerify the control voltage matches the nameplate before applying power.\u003c\/li\u003e\n\u003cli\u003eSet the trip class and overload current according to the motor full-load current.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Allen-Bradley \u003cstrong\u003e150-F251NBRD\u003c\/strong\u003e SMC Flex smart motor controller\u003c\/li\u003e\n\u003cli\u003eOne display module (pre-installed)\u003c\/li\u003e\n\u003cli\u003eOne terminal cover set for IP2X protection\u003c\/li\u003e\n\u003cli\u003eOne instruction sheet for wiring and setup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping Methods\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx\u003c\/li\u003e\n\u003cli\u003eUPS\u003c\/li\u003e\n\u003cli\u003eDHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the controller rating of the 150-F251NBRD?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e150-F251NBRD\u003c\/strong\u003e rates 251 A and delivers 100–200 Hp at 460 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this soft starter include internal bypass?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the unit includes internal bypass for efficient continuous operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What trip classes does this model support?\u003c\/strong\u003e\u003cbr\u003eA: It supports trip classes 10, 15, 20, and 30.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this controller for delta-connected motors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it handles delta connected motor current from 145–435 A at 500\/575 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The open-type operating temperature ranges from -5 to 50 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How much does the 150-F251NBRD weigh?\u003c\/strong\u003e\u003cbr\u003eA: The unit weighs 30.4 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the product new and in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we offer brand new original units and keep them in stock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days using DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support 30-day returns.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47640375394465,"sku":"150-F251NBRD","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F251NBRD.jpg?v=1789710776"},{"product_id":"150-f480nbdd-allen-bradley-smc-flex-480a-motor-controller","title":"150-F480NBDD Allen-Bradley SMC Flex 480A Motor Controller","description":"\u003ch2\u003e\u003cstrong\u003e150-F480NBDD SMC Flex Open Smart Motor Controller – 480 A Solid State Controller by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F480NBDD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController type:\u003c\/strong\u003e Bulletin 150, solid state controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController rating:\u003c\/strong\u003e 480 A, 200–400 Hp @ 460 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure type:\u003c\/strong\u003e Open\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput line voltage:\u003c\/strong\u003e 200–480 V AC, 3-phase, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl voltage:\u003c\/strong\u003e 100–240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Braking control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Performance Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSolid state design reduces mechanical wear on motor contacts.\u003c\/li\u003e\n\u003cli\u003eBraking control option stops the motor quickly without extra equipment.\u003c\/li\u003e\n\u003cli\u003eOpen enclosure suits panel mounting inside a protective cabinet.\u003c\/li\u003e\n\u003cli\u003eThree-phase input supports 50 Hz and 60 Hz power systems.\u003c\/li\u003e\n\u003cli\u003eWide control voltage range simplifies integration with existing control circuits.\u003c\/li\u003e\n\u003cli\u003e480 A current rating handles large industrial motors up to 400 Hp.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller vertically on a flat surface inside a suitable enclosure.\u003c\/li\u003e\n\u003cli\u003eKeep minimum clearance above and below the heatsink for proper airflow.\u003c\/li\u003e\n\u003cli\u003eConnect three-phase input lines to the designated power terminals.\u003c\/li\u003e\n\u003cli\u003eWire the 100–240 V AC control circuit to the correct control terminals.\u003c\/li\u003e\n\u003cli\u003eVerify input voltage and control voltage match the nameplate before power-up.\u003c\/li\u003e\n\u003cli\u003eSet the braking control parameters according to your motor and load.\u003c\/li\u003e\n\u003cli\u003eTighten all power and control connections to the recommended torque.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Allen-Bradley \u003cstrong\u003e150-F480NBDD\u003c\/strong\u003e SMC Flex solid state controller\u003c\/li\u003e\n\u003cli\u003eOne terminal cover set\u003c\/li\u003e\n\u003cli\u003eOne instruction sheet for wiring and setup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping Methods\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx\u003c\/li\u003e\n\u003cli\u003eUPS\u003c\/li\u003e\n\u003cli\u003eDHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F480NBDD?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e150-F480NBDD\u003c\/strong\u003e rates 480 A and delivers 200–400 Hp at 460 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What input voltage does this controller accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 200–480 V AC, three-phase, at 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does this model use?\u003c\/strong\u003e\u003cbr\u003eA: It uses 100–240 V AC control voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this controller include braking control?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the braking control option comes built in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What enclosure type does the 150-F480NBDD have?\u003c\/strong\u003e\u003cbr\u003eA: It comes in an open type enclosure for panel mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the product new and in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we offer brand new original units and keep them in stock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days using DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support 30-day returns.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47641385730209,"sku":"150-F480NBDD","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F480NBDD.jpg?v=1789710952"},{"product_id":"150-f780nbed-allen-bradley-smc-flex-open-600hp","title":"150-F780NBED Allen-Bradley SMC Flex Open 600Hp","description":"\u003ch2\u003e\u003cstrong\u003e150-F780NBED SMC Flex Open Smart Motor Controller – 780 A Solid State Controller by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F780NBED\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController type:\u003c\/strong\u003e Bulletin 150, solid state controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController rating:\u003c\/strong\u003e 780 A, 600 Hp @ 460 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure type:\u003c\/strong\u003e Open\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput line voltage:\u003c\/strong\u003e 200–480 V AC, 3-phase, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl voltage:\u003c\/strong\u003e 100–120 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Braking control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Performance Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSolid state design cuts mechanical wear on motor contacts and extends service life.\u003c\/li\u003e\n\u003cli\u003eBraking control option stops the motor quickly without additional equipment.\u003c\/li\u003e\n\u003cli\u003eOpen enclosure suits panel mounting inside a protective cabinet.\u003c\/li\u003e\n\u003cli\u003eThree-phase input supports both 50 Hz and 60 Hz power systems.\u003c\/li\u003e\n\u003cli\u003e780 A current rating drives large industrial motors up to 600 Hp.\u003c\/li\u003e\n\u003cli\u003e100–120 V AC control voltage matches common North American control circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller vertically on a flat surface inside a suitable enclosure.\u003c\/li\u003e\n\u003cli\u003eKeep minimum clearance above and below the heatsink for proper airflow.\u003c\/li\u003e\n\u003cli\u003eConnect three-phase input lines to the designated power terminals.\u003c\/li\u003e\n\u003cli\u003eWire the 100–120 V AC control circuit to the correct control terminals.\u003c\/li\u003e\n\u003cli\u003eVerify input voltage and control voltage match the nameplate before power-up.\u003c\/li\u003e\n\u003cli\u003eSet the braking control parameters according to your motor and load.\u003c\/li\u003e\n\u003cli\u003eTighten all power and control connections to the recommended torque.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Allen-Bradley \u003cstrong\u003e150-F780NBED\u003c\/strong\u003e SMC Flex solid state controller\u003c\/li\u003e\n\u003cli\u003eOne terminal cover set\u003c\/li\u003e\n\u003cli\u003eOne instruction sheet for wiring and setup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping Methods\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx\u003c\/li\u003e\n\u003cli\u003eUPS\u003c\/li\u003e\n\u003cli\u003eDHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F780NBED?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e150-F780NBED\u003c\/strong\u003e rates 780 A and delivers 600 Hp at 460 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What input voltage does this controller accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 200–480 V AC, three-phase, at 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does this model use?\u003c\/strong\u003e\u003cbr\u003eA: It uses 100–120 V AC control voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this controller include braking control?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the braking control option comes built in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What enclosure type does the 150-F780NBED have?\u003c\/strong\u003e\u003cbr\u003eA: It comes in an open type enclosure for panel mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the product new and in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we offer brand new original units and keep them in stock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days using DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support 30-day returns.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47641844809889,"sku":"150-F780NBED","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F780NBED.jpg?v=1789712005"},{"product_id":"150-f1250nbed-allen-bradley-smc-flex-1250a-controller","title":"150-F1250NBED Allen-Bradley SMC Flex 1250A Controller","description":"\u003ch2\u003e\u003cstrong\u003e150-F1250NBED SMC Flex Open Smart Motor Controller – 1250 A Solid State Controller by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F1250NBED\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController type:\u003c\/strong\u003e Bulletin 150, solid state controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController rating:\u003c\/strong\u003e 1250 A, 1000 Hp @ 460 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure type:\u003c\/strong\u003e Open\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput line voltage:\u003c\/strong\u003e 200–480 V AC, 3-phase, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl voltage:\u003c\/strong\u003e 100–120 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Braking control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Performance Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSolid state design cuts mechanical wear on motor contacts and extends service life.\u003c\/li\u003e\n\u003cli\u003eBraking control option stops the motor quickly without additional equipment.\u003c\/li\u003e\n\u003cli\u003eOpen enclosure suits panel mounting inside a protective cabinet.\u003c\/li\u003e\n\u003cli\u003eThree-phase input supports both 50 Hz and 60 Hz power systems.\u003c\/li\u003e\n\u003cli\u003e1250 A current rating drives very large industrial motors up to 1000 Hp.\u003c\/li\u003e\n\u003cli\u003e100–120 V AC control voltage matches common North American control circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller vertically on a flat surface inside a suitable enclosure.\u003c\/li\u003e\n\u003cli\u003eKeep minimum clearance above and below the heatsink for proper airflow.\u003c\/li\u003e\n\u003cli\u003eConnect three-phase input lines to the designated power terminals.\u003c\/li\u003e\n\u003cli\u003eWire the 100–120 V AC control circuit to the correct control terminals.\u003c\/li\u003e\n\u003cli\u003eVerify input voltage and control voltage match the nameplate before power-up.\u003c\/li\u003e\n\u003cli\u003eSet the braking control parameters according to your motor and load.\u003c\/li\u003e\n\u003cli\u003eTighten all power and control connections to the recommended torque.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Allen-Bradley \u003cstrong\u003e150-F1250NBED\u003c\/strong\u003e SMC Flex solid state controller\u003c\/li\u003e\n\u003cli\u003eOne terminal cover set\u003c\/li\u003e\n\u003cli\u003eOne instruction sheet for wiring and setup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping Methods\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx\u003c\/li\u003e\n\u003cli\u003eUPS\u003c\/li\u003e\n\u003cli\u003eDHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F1250NBED?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e150-F1250NBED\u003c\/strong\u003e rates 1250 A and delivers 1000 Hp at 460 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What input voltage does this controller accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 200–480 V AC, three-phase, at 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does this model use?\u003c\/strong\u003e\u003cbr\u003eA: It uses 100–120 V AC control voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this controller include braking control?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the braking control option comes built in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What enclosure type does the 150-F1250NBED have?\u003c\/strong\u003e\u003cbr\u003eA: It comes in an open type enclosure for panel mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the product new and in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we offer brand new original units and keep them in stock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days using DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support 30-day returns.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47643446542497,"sku":"150-F1250NBED","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F1250NBED.jpg?v=1789712257"},{"product_id":"150-f135nbdd-allen-bradley-smc-flex-soft-starter","title":"150-F135NBDD Allen-Bradley SMC Flex Soft Starter","description":"\u003ch2\u003e\u003cstrong\u003e150-F135NBDD SMC Flex Smart Motor Controller – 135 A Soft Starter by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F135NBDD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Soft starter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 135 A, 25–100 Hp @ 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 100…240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage Ue:\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Control Supply Voltage:\u003c\/strong\u003e 100 V at 50 Hz and 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current (Line Connected):\u003c\/strong\u003e 34 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current (Delta Connected):\u003c\/strong\u003e 59 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Classes:\u003c\/strong\u003e 10, 15, 20 and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Current Rating:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e117% of motor FLC\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Current:\u003c\/strong\u003e 34…135 A @ 600\/Y\/690V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Current:\u003c\/strong\u003e 59…234 A @ 500\/575V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Power, max:\u003c\/strong\u003e 90 kW @ 500V AC @ 50Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Power, max:\u003c\/strong\u003e 75 kW @ 230V AC @ 50Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e Rated 500V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e 200…480V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Voltage:\u003c\/strong\u003e 6000V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Withstand:\u003c\/strong\u003e 2500V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT Protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive Peak Inverse Voltage:\u003c\/strong\u003e 1400V per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Metal oxide varistors: 220 J (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection Device List:\u003c\/strong\u003e Standard fuse, circuit breaker and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity Available Fault Current, max:\u003c\/strong\u003e 70kA @ 600V with 400 A time delay Class J or Class L fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Available Fault Current, max:\u003c\/strong\u003e 70kA @ 690V for maximum FLC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControl and Monitoring Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWith Display:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Type for Actuating:\u003c\/strong\u003e AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Options:\u003c\/strong\u003e Brake control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Controller Feature:\u003c\/strong\u003e Status indication for stopped, starting, stopping, at speed, alarm and fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Controller Feature:\u003c\/strong\u003e SMB smart motor braking control with adjustable braking current from 0…400% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motor Overload Protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Protection Device Performance (SCPD) Type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Sensors, max:\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Control Module:\u003c\/strong\u003e 5A @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = open), max:\u003c\/strong\u003e 30V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Watts Control Module:\u003c\/strong\u003e 60 W @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Watts Control Module:\u003c\/strong\u003e 24 W @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = 4 kΩ), max:\u003c\/strong\u003e \u0026lt;7.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 800 ms for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Time Control Module:\u003c\/strong\u003e 250 ms @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Time Control Module:\u003c\/strong\u003e 500 ms @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Resistance of PTC Sensor Chain, max:\u003c\/strong\u003e 1500 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Input:\u003c\/strong\u003e 0…5V DC @ 4.5V DC = 100% Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllen Bradley Power Supply Control Module, min:\u003c\/strong\u003e 1606-XLP50E @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Trip Resistance:\u003c\/strong\u003e 25 Ω ± 10 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Resistance:\u003c\/strong\u003e 3400 Ω ± 150 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Resistance:\u003c\/strong\u003e 1600 Ω ± 100 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Voltage, max:\u003c\/strong\u003e 50V AC @ 10V DC\/12V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Voltage, min:\u003c\/strong\u003e 85V AC @ 19.2V DC\/20.4V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Current:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Current:\u003c\/strong\u003e 20mA @ 120V AC\/40mA @ 240V AC, 7.6mA @ 24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAuxiliary Contacts and Relay Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Contacts:\u003c\/strong\u003e 1 for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Current:\u003c\/strong\u003e AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional Thermal Current (Ith):\u003c\/strong\u003e AC\/DC: 5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Control Circuit:\u003c\/strong\u003e Electromagnetic relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Contacts:\u003c\/strong\u003e Programmable NO\/NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current:\u003c\/strong\u003e 3A @ 120V AC, 1.5A @ 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3) and 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake:\u003c\/strong\u003e 3600VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreak:\u003c\/strong\u003e 360VA for auxiliary contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eThermal, Environmental and Mechanical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Heat Dissipation with Control and Fan Power:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e104 W\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage and Transportation Temperature:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5…95% (noncondensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Open: -5 to 50 °C (23 to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Electrical Shock:\u003c\/strong\u003e IP2X (with terminal covers) per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Emission Levels:\u003c\/strong\u003e Radiated emission: Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity Levels:\u003c\/strong\u003e Surge transient per EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 15 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Opsal: 5.5 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 196.4 mm (7.74 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 212.2 mm (8.35 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 443.7 mm (17.47 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction and Installation Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Pole Construction:\u003c\/strong\u003e Heatsink hockey puck thyristor modular design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Bypass:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Single direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Terminal Markings:\u003c\/strong\u003e NEMA, CENELEC EN50 012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Terminals:\u003c\/strong\u003e Clamping yoke connection, M3 screw clamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine\/Load Side Power Terminals:\u003c\/strong\u003e One M10 x 1.5 diam hole per power pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Modules Construction:\u003c\/strong\u003e Thermoset and thermoplastic moldings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetal Parts Construction:\u003c\/strong\u003e Plated brass, copper or painted steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransformer Control Module:\u003c\/strong\u003e 75VA @ 100…240V AC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatsink Fan Rating:\u003c\/strong\u003e 20VA @ 110\/120V AC or 220\/240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilization Category:\u003c\/strong\u003e MG 1 per UL\/CSA\/NEMA for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpere Tested European Style, max:\u003c\/strong\u003e 6,9 gRB 73xxx400 6,6URD33xxx500 @ 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpere Tested North American Style, max:\u003c\/strong\u003e A070URD33xxx500 @ 690V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley \u003cstrong\u003e150-F135NBDD\u003c\/strong\u003e SMC Flex Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e1 x Terminal cover set for power circuit\u003c\/li\u003e\n\u003cli\u003e1 x Installation and user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship worldwide via FedEx, UPS and DHL.\u003c\/li\u003e\n\u003cli\u003eWe keep this model in stock and dispatch within 5 days.\u003c\/li\u003e\n\u003cli\u003eWe support 30-day returns for eligible orders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F135NBDD?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e150-F135NBDD\u003c\/strong\u003e carries a 135 A controller rating and supports 25–100 Hp at 460V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this soft starter include integrated motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes integrated motor overload protection and supports trip classes 10, 15, 20 and 30.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does this model accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 100…240V AC control voltage and operates at 50\/60 Hz for the power circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this controller with delta connected motors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports delta connected motor current from 59…234 A at 500\/575V AC, 3-phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The open type unit operates from -5 to 50 °C (23 to 122 °F) with humidity from 5…95% noncondensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it come with a display?\u003c\/strong\u003e\u003cbr\u003eA: Yes, this SMC Flex controller includes a display for status indication and fault monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS and DHL, and we usually dispatch within 5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support 30-day returns. The product is brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information Inquiries\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmail: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhone \/ WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47643994882209,"sku":"150-F135NBDD","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F135NBDD.jpg?v=1789713389"},{"product_id":"150-f5nbdd-allen-bradley-5a-motor-controller","title":"150-F5NBDD Allen-Bradley 5A Motor Controller","description":"\u003ch2\u003e\u003cstrong\u003e150-F5NBDD SMC Flex Smart Motor Controller – 5 A Soft Starter by Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e150-F5NBDD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Soft starter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 5 A, 0.5–3.0 Hp @ 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 100…240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage Ue:\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Control Supply Voltage:\u003c\/strong\u003e 100 V at 50 Hz and 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current (Line Connected):\u003c\/strong\u003e 1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Current (Delta Connected):\u003c\/strong\u003e 1.7 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Classes:\u003c\/strong\u003e 10, 15, 20 and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Current Rating:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e117% of motor FLC\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Current:\u003c\/strong\u003e 1…5 A @ 500\/575V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Current:\u003c\/strong\u003e 1.7…8.7 A @ 500\/575V AC, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Connected Motor Power, max:\u003c\/strong\u003e 3 Hp @ 575V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelta Connected Motor Power, max:\u003c\/strong\u003e 7.5 Hp @ 575V AC, 60 Hz, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e Rated 500V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e 200…480V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Voltage:\u003c\/strong\u003e 6000V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Withstand:\u003c\/strong\u003e 2500V per IEC for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT Protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetitive Peak Inverse Voltage:\u003c\/strong\u003e 1400V per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Metal oxide varistors: 220 J (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection Device List:\u003c\/strong\u003e Standard fuse, circuit breaker and high capacity time delay class CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity Available Fault Current, max:\u003c\/strong\u003e 70kA @ 600V with 17.5 A time delay Class J or Class L fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Available Fault Current, max:\u003c\/strong\u003e 5kA @ 200…600V with maximum standard fuse 35 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControl and Monitoring Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWith Display:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Type for Actuating:\u003c\/strong\u003e AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Options:\u003c\/strong\u003e Brake control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Controller Feature:\u003c\/strong\u003e Status indication for stopped, starting, stopping, at speed, alarm and fault\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Controller Feature:\u003c\/strong\u003e SMB smart motor braking control with adjustable braking current from 0…400% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motor Overload Protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Protection Device Performance (SCPD) Type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Sensors, max:\u003c\/strong\u003e 6 for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Control Module:\u003c\/strong\u003e 5A @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = open), max:\u003c\/strong\u003e 30V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Watts Control Module:\u003c\/strong\u003e 60 W @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Watts Control Module:\u003c\/strong\u003e 24 W @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage at PTC Terminals (RPTC = 4 kΩ), max:\u003c\/strong\u003e \u0026lt;7.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 800 ms for PTC input ratings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Time Control Module:\u003c\/strong\u003e 250 ms @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Time Control Module:\u003c\/strong\u003e 500 ms @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Resistance of PTC Sensor Chain, max:\u003c\/strong\u003e 1500 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Input:\u003c\/strong\u003e 0…5V DC @ 4.5V DC = 100% Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllen Bradley Power Supply Control Module, min:\u003c\/strong\u003e 1606-XLP50E @ 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Trip Resistance:\u003c\/strong\u003e 25 Ω ± 10 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Resistance:\u003c\/strong\u003e 3400 Ω ± 150 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Resistance:\u003c\/strong\u003e 1600 Ω ± 100 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Voltage, max:\u003c\/strong\u003e 50V AC @ 10V DC\/12V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Voltage, min:\u003c\/strong\u003e 85V AC @ 19.2V DC\/20.4V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput OFF-State Current:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON-State Current:\u003c\/strong\u003e 20mA @ 120V AC\/40mA @ 240V AC, 7.6mA @ 24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAuxiliary Contacts and Relay Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Contacts:\u003c\/strong\u003e 1 for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Current:\u003c\/strong\u003e AC for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional Thermal Current (Ith):\u003c\/strong\u003e AC\/DC: 5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Control Circuit:\u003c\/strong\u003e Electromagnetic relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Contacts:\u003c\/strong\u003e Programmable NO\/NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current:\u003c\/strong\u003e 3A @ 120V AC, 1.5A @ 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Auxiliary contacts 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3) and 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake:\u003c\/strong\u003e 3600VA for auxiliary contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreak:\u003c\/strong\u003e 360VA for auxiliary contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eThermal, Environmental and Mechanical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady State Heat Dissipation with Control and Fan Power:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e70 W\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage and Transportation Temperature:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5…95% (noncondensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Open: -5 to 50 °C (23 to 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Electrical Shock:\u003c\/strong\u003e IP20 per IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Emission Levels:\u003c\/strong\u003e Radiated emission: Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity Levels:\u003c\/strong\u003e Surge transient per EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.7 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Opsal: 15 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 150 mm (5.90 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 203 mm (8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 321 mm (12.60 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the current rating of the 150-F5NBDD?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e150-F5NBDD\u003c\/strong\u003e carries a 5 A controller rating and supports 0.5–3.0 Hp at 460V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this soft starter include integrated motor overload protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes integrated motor overload protection and supports trip classes 10, 15, 20 and 30.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What control voltage does this model accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 100…240V AC control voltage and operates at 50\/60 Hz for the power circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this controller with delta connected motors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports delta connected motor current from 1.7…8.7 A at 500\/575V AC, 3-phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The open type unit operates from -5 to 50 °C (23 to 122 °F) with humidity from 5…95% noncondensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it come with a display?\u003c\/strong\u003e\u003cbr\u003eA: Yes, this SMC Flex controller includes a display for status indication and fault monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What cable size does the power terminal accept?\u003c\/strong\u003e\u003cbr\u003eA: The line side accepts 2.5…95 mm² (14…3 AWG) and the load side accepts 2.5…50 mm² (14…1 AWG).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the tightening torque for the power terminals?\u003c\/strong\u003e\u003cbr\u003eA: The power terminals require 14.7 Nm (130 in-lb) of tightening torque.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS and DHL, and we usually dispatch within 5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support 30-day returns. The product is brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information Inquiries\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmail: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhone \/ WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47645426450593,"sku":"150-F5NBDD","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F5NBDD.jpg?v=1789713555"}],"url":"https:\/\/www.autonexcontrol.com\/collections\/allen-bradley-motors.oembed?page=4","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}