{"product_id":"tc-iah061-analog-input-module-honeywell","title":"TC-IAH061 Analog Input Module Honeywell","description":"\u003ch2\u003eHoneywell TC-IAH061 High-Performance Analog Input Module\u003c\/h2\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eManufacturer:\u003c\/span\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eProduct Number:\u003c\/span\u003e TC-IAH061\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eProduct Type:\u003c\/span\u003e Experion Analog Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eChannel Configuration:\u003c\/span\u003e 6 galvanically isolated channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eAccuracy:\u003c\/span\u003e High-precision measurement capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eOpen Circuit Detection:\u003c\/span\u003e Upscale reading (Voltage); Zero scale reading (Current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eDetection Timing:\u003c\/span\u003e 5 seconds (Voltage); 1 second (Current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eChannel Bandwidth:\u003c\/span\u003e 0 to 15 Hz (-3 dB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eRFI Immunity:\u003c\/span\u003e Less than 2.0% range error at 10 V\/m, 27 to 1000 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003ePower Requirements:\u003c\/span\u003e 4.3 W maximum power dissipation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eUpdate Performance:\u003c\/span\u003e 25 ms module update rate for all channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eConnection System:\u003c\/span\u003e TC_TBNH 20-position terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eIsolation Rating:\u003c\/span\u003e Galvanic isolation between all channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module in approved Honeywell Experion chassis\u003c\/li\u003e\n\u003cli\u003eUse specified TC_TBNH terminal blocks for all wiring\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance for ventilation and heat dissipation\u003c\/li\u003e\n\u003cli\u003eFollow EMC guidelines for optimal RFI immunity performance\u003c\/li\u003e\n\u003cli\u003eVerify channel isolation during system commissioning\u003c\/li\u003e\n\u003cli\u003eConfigure open circuit detection per application requirements\u003c\/li\u003e\n\u003cli\u003eTest all six channels at maximum update rate capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the product condition?\u003c\/strong\u003e - All modules are brand new and original Honeywell equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this item in stock?\u003c\/strong\u003e - Yes, we maintain current inventory for immediate shipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your shipping time?\u003c\/strong\u003e - We process and ship all orders within 5 business days\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich shipping methods are available?\u003c\/strong\u003e - We use DHL, FedEx, and UPS for reliable delivery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your return policy?\u003c\/strong\u003e - We provide 30-day return support for customer satisfaction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many channels does this module have?\u003c\/strong\u003e - The TC-IAH061 provides six isolated input channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the module update rate?\u003c\/strong\u003e - It updates all six channels every 25 milliseconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat type of isolation is provided?\u003c\/strong\u003e - All channels feature galvanic isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat terminal block is required?\u003c\/strong\u003e - Use TC_TBNH 20-position terminal blocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the power consumption?\u003c\/strong\u003e - Maximum power dissipation is 4.3 watts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor technical support and purchasing information about the \u003cstrong\u003eHoneywell TC-IAH061\u003c\/strong\u003e, please contact: \u003cstrong\u003e\u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45232828448929,"sku":"TC-IAH061","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/TC-ODD321_3.jpg?v=1761097564","url":"https:\/\/www.autonexcontrol.com\/az\/products\/tc-iah061-analog-input-module-honeywell","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}