{"product_id":"ic670mdl742-ge-fanuc-negative-output-module","title":"IC670MDL742 GE Fanuc Negative Output Module","description":"\u003ch2\u003eGE Fanuc IC670MDL742 Negative Logic DC Output Module\u003c\/h2\u003e\n\u003ch3\u003eCore Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #2e86c1;\"\u003eGE Fanuc\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e86c1;\"\u003e\u003cstrong\u003eIC670MDL742\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Field Control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Negative Logic (Current Sinking)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e \u003cspan style=\"color: #2e86c1;\"\u003e16 discrete points\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrouping:\u003c\/strong\u003e 1 group (No point-to-point isolation within group)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser Input Voltage:\u003c\/strong\u003e 4.75-5.25V DC and 10.5-28.5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 4.5 to 28.25 Volts DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e \u003cspan style=\"color: #2e86c1;\"\u003e0.5 Amps per point maximum\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Steady-State Load:\u003c\/strong\u003e \u003cspan style=\"color: #2e86c1;\"\u003e8 Amps maximum for the entire module\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Drop:\u003c\/strong\u003e 0.25 volts maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 111 mA from backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e 2 Amps max for 100ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Leakage Current:\u003c\/strong\u003e 250 µA at 28.5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Optoisolators separate logic from field outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features \u0026amp; Design\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module draws logic power directly from the Field Control bus interface unit.\u003c\/li\u003e\n\u003cli\u003eAn external DC power supply must connect to the module to power the field loads.\u003c\/li\u003e\n\u003cli\u003eA clearly visible, \u003cspan style=\"color: #2e86c1;\"\u003e10-Amp fuse\u003c\/span\u003e protects against overcurrent and reverse polarity.\u003c\/li\u003e\n\u003cli\u003eEach output uses a FET switch controlled by the external supply to sink current.\u003c\/li\u003e\n\u003cli\u003eA transparent cover provides a clear view of all status indicator LEDs.\u003c\/li\u003e\n\u003cli\u003eThe PWR LED indicates the presence of backplane power and fuse status.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eIC670MDL742\u003c\/strong\u003e module communicates and receives data via the bus interface unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Environmental Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module securely on the compatible Field Control rack or base unit.\u003c\/li\u003e\n\u003cli\u003eEnsure the external load power supply voltage falls within the 4.5-28.25V DC range.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the 0.5A per point or 8A total module current rating.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for standard industrial control panel environments.\u003c\/li\u003e\n\u003cli\u003eIt has no group-to-group isolation, so plan your wiring accordingly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Shipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Includes:\u003c\/strong\u003e 1x GE Fanuc \u003cstrong\u003eIC670MDL742\u003c\/strong\u003e Output Module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e We ship globally via reliable carriers like FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e All our modules are \u003cstrong\u003ebrand new and original\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStock \u0026amp; Delivery:\u003c\/strong\u003e We have items in stock and typically ship within \u003cstrong\u003e5 business days\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does \"negative logic\" or \"current sinking\" mean for this module?\u003c\/strong\u003e\u003cbr\u003eA: It means each output acts like a switch to the negative\/ground side. To turn on a load, you connect the load's positive side to your power supply positive, and the load's negative side to the module output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use a single 24V DC power supply for the entire module's 16 outputs?\u003c\/strong\u003e\u003cbr\u003eA: Yes, but you must ensure the total current of all active outputs does not exceed the module's \u003cspan style=\"color: #2e86c1;\"\u003e8 Amp total limit\u003c\/span\u003e and your power supply's capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is there protection if I accidentally wire the external power backwards?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the built-in \u003cspan style=\"color: #2e86c1;\"\u003e10-Amp fuse\u003c\/span\u003e helps protect the module from damage due to reverse polarity connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the status of your inventory and shipping time?\u003c\/strong\u003e\u003cbr\u003eA: We maintain stock of the \u003cstrong\u003eIC670MDL742\u003c\/strong\u003e and aim to dispatch orders within 5 business days via carriers like DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We offer a \u003cstrong\u003e30-day return policy\u003c\/strong\u003e for unused items in their original packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePartner: \u003cstrong\u003eNexAuto Technology Limited\u003c\/strong\u003e : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45495232528545,"sku":"IC670MDL742","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC670MDL742.jpg?v=1764839820","url":"https:\/\/www.autonexcontrol.com\/az\/products\/ic670mdl742-ge-fanuc-negative-output-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}