{"product_id":"honeywell-universal-i-o-module-900u01-0100-16-channel","title":"Honeywell Universal I\/O Module 900U01-0100 | 16-Channel","description":"\u003ch2\u003eHoneywell Universal Input\/Output Module 900U01-0100\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003e900U01-0100\u003c\/strong\u003e Universal I\/O Module delivers exceptional flexibility for industrial automation systems. This advanced Honeywell module supports software-configurable channels that adapt to your specific application needs with precision performance.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration Flexibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides \u003cspan style=\"color: #ff6600;\"\u003e16 fully configurable channels\u003c\/span\u003e that operate as AI, AO, DI, or DO\u003c\/li\u003e\n\u003cli\u003eOffers complete galvanic isolation with \u003cspan style=\"color: #ff6600;\"\u003e1kV AC protection\u003c\/span\u003e between logic and field circuits\u003c\/li\u003e\n\u003cli\u003eSupports HART communication protocol on all analog input and output channels\u003c\/li\u003e\n\u003cli\u003eEnables flexible field power supply operation from 22V DC to 27V DC range\u003c\/li\u003e\n\u003cli\u003eDelivers maximum 4.2 amps total load capacity with 500 mA per channel limit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAnalog Input Performance Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Types:\u003c\/strong\u003e 0-20mA or 4-20mA current loops with 2,3,4-wire device support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConverter Resolution:\u003c\/strong\u003e 16-bit A\/D conversion for precise measurement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 250 ohm nominal resistance for signal conditioning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy Rating:\u003c\/strong\u003e 0.1% full-scale at 23.5°C, 0.25% across 0-60°C range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Isolation:\u003c\/strong\u003e 58dB crosstalk rejection between adjacent channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Protection:\u003c\/strong\u003e Handles up to 30V maximum input voltage safely\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Capability:\u003c\/strong\u003e Supports one HART multi-drop device per channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAnalog Output Technical Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 6 maximum current loop outputs with HART support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Range:\u003c\/strong\u003e 0-23mA directly settable current output range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Capacity:\u003c\/strong\u003e 100-500 ohm resistive load compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Resolution:\u003c\/strong\u003e 12-bit digital-to-analog conversion precision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance Voltage:\u003c\/strong\u003e 14VDC maximum output compliant voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e Better than 0.5% full-scale accuracy at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFail-Safe Options:\u003c\/strong\u003e Hold last value or predefined failsafe value\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDigital Input \u0026amp; Output Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Input Voltage:\u003c\/strong\u003e 24V open circuit voltage detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Detection:\u003c\/strong\u003e 15kΩ open contact, 5kΩ closed contact sensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Sensing:\u003c\/strong\u003e 7mA short circuit, 0.9mA lead breakage detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Output Type:\u003c\/strong\u003e Solid-state sourcing with short-circuit protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 0.5A maximum per channel, 4.2A module total\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current:\u003c\/strong\u003e Less than 0.1mA off-state leakage current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Speed:\u003c\/strong\u003e 100Hz low-pass filtering on all digital channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the Honeywell \u003cstrong\u003e900U01-0100\u003c\/strong\u003e module in compatible industrial automation racks\u003c\/li\u003e\n\u003cli\u003eConfigure channel types through software interface for application requirements\u003c\/li\u003e\n\u003cli\u003eEnsure field power supply remains within 22-27V DC specified operating range\u003c\/li\u003e\n\u003cli\u003eImplement proper grounding for optimal noise immunity and signal integrity\u003c\/li\u003e\n\u003cli\u003eUtilize HART communicator for device configuration and calibration procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Delivery Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEach package contains one Honeywell Universal I\/O Module \u003cstrong\u003e900U01-0100\u003c\/strong\u003e unit\u003c\/li\u003e\n\u003cli\u003eIncludes installation manual and configuration guide documentation\u003c\/li\u003e\n\u003cli\u003eAll modules undergo full functional testing before shipment\u003c\/li\u003e\n\u003cli\u003eProfessional protective packaging ensures safe transit to your facility\u003c\/li\u003e\n\u003cli\u003eExpress shipping available via FedEx, UPS, and DHL carrier services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHow many channels can operate simultaneously as analog outputs?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe Honeywell module supports up to 6 analog output channels maximum, depending on load resistance configuration and power requirements.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat temperature range maintains specified accuracy for analog inputs?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHoneywell analog inputs maintain 0.25% full-scale accuracy across the entire 0°C to +60°C operating temperature range.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan digital outputs handle inductive loads like solenoids and relays?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eYes, the Honeywell solid-state outputs provide short-circuit protection and can drive inductive loads up to 0.5A per channel.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat happens during power loss with configured fail-safe settings?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe Honeywell module will either hold the last known value or switch to predefined fail-safe values based on your configuration.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHow does the open wire detection function work on digital inputs?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe Honeywell system monitors current flow, detecting lead breakage below 0.9mA and short circuits above 6mA with 5% accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45280634536097,"sku":"900U01-0100","price":314.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/900U01-0100.jpg?v=1761634906","url":"https:\/\/www.autonexcontrol.com\/az\/products\/honeywell-universal-i-o-module-900u01-0100-16-channel","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}