{"product_id":"honeywell-fs-sdo-0448-48v-dc-safety-output","title":"Honeywell FS-SDO-0448 48V DC Safety Output","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell FS-SDO-0448 Safe Digital Output Module Introduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eHoneywell FS-SDO-0448\u003c\/span\u003e\u003c\/strong\u003e is a medium-voltage safe digital output module engineered for safety instrumented systems. It delivers reliable 48V DC switching with enhanced safety features for critical industrial applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eFS-SDO-0448\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Safe Digital Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certification:\u003c\/strong\u003e TÜV certified for \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eSIL 3 \/ PLe\u003c\/span\u003e\u003c\/strong\u003e per IEC 61508 and IEC 62061\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 4 isolated output channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 48 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Continuous Current:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003e0.75 A\u003c\/span\u003e\u003c\/strong\u003e per channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical \u0026amp; Performance Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Solid-state MOSFET with active diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e 36 W per channel (48Vdc × 0.75A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Resistance:\u003c\/strong\u003e ≤ 1.2 Ω per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current (Off-state):\u003c\/strong\u003e ≤ 0.8 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e ≤ 10 ms (transition in either direction)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Coverage (DC):\u003c\/strong\u003e ≥ 92%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbability of Dangerous Failure per Hour (PFH):\u003c\/strong\u003e \u0026lt; 1.0 × 10⁻⁹\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Power Supply:\u003c\/strong\u003e 24 Vdc ±20%, 150 mA typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Dimensions:\u003c\/strong\u003e 45 mm × 120 mm × 115 mm (W × H × D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35 mm DIN rail (EN 60715 compliant)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Spring-cage clamp terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Size Range:\u003c\/strong\u003e 0.25 - 2.5 mm² (AWG 22-14)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 0.4 Nm (spring-cage, no tool required for insertion)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 5 g (10 - 150 Hz per IEC 60068-2-6)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication \u0026amp; System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControls 48V DC safety devices including solenoid valves, motor contactors, and alarm beacons\u003c\/li\u003e\n\u003cli\u003eSuitable for Emergency Shutdown (ESD), Fire \u0026amp; Gas (F\u0026amp;G), and Turbomachinery Control systems\u003c\/li\u003e\n\u003cli\u003eSeamless integration with Honeywell Safety Manager SC and Experion HS platforms\u003c\/li\u003e\n\u003cli\u003eSupports hot-swappable maintenance in redundant configurations\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators per channel for operational diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Configuration Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall on DIN rail with proper spacing for heat dissipation\u003c\/li\u003e\n\u003cli\u003eConnect 48V DC field power supply to output terminals\u003c\/li\u003e\n\u003cli\u003eUse Safety Builder software (version 4.1 or higher) for configuration\u003c\/li\u003e\n\u003cli\u003eEnsure wiring does not exceed 0.75A continuous current per channel\u003c\/li\u003e\n\u003cli\u003eImplement proper cable separation for safety and non-safety circuits\u003c\/li\u003e\n\u003cli\u003eVerify diagnostic functions during commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging \u0026amp; Shipping Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eHoneywell FS-SDO-0448\u003c\/strong\u003e is packaged in anti-static, moisture-resistant materials\u003c\/li\u003e\n\u003cli\u003ePackage includes module, configuration label, and safety documentation\u003c\/li\u003e\n\u003cli\u003eShipping via \u003cstrong\u003eFedEx, DHL, or UPS\u003c\/strong\u003e with real-time tracking\u003c\/li\u003e\n\u003cli\u003eExport compliance documentation provided for international shipments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat safety certification does it have?\u003c\/strong\u003e \u003cstrong\u003eTÜV certified for SIL 3 \/ PLe\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the output voltage and current?\u003c\/strong\u003e \u003cstrong\u003e48V DC, 0.75A per channel\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many output channels?\u003c\/strong\u003e \u003cstrong\u003e4 independently controlled channels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat diagnostics are available?\u003c\/strong\u003e Short-circuit, open-circuit, overload, and thermal diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs it suitable for redundant systems?\u003c\/strong\u003e Yes, designed for 1oo2D (one-out-of-two with diagnostics) architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor technical datasheets or to order the \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eHoneywell FS-SDO-0448\u003c\/span\u003e\u003c\/strong\u003e, contact us.\u003cbr\u003eEmail: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner NexAuto Technology Limited :\u003cbr\u003e\u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e© 2025 AutoNex Controls Limited. All rights reserved.\u003cbr\u003eOriginal Source: AutoNex Controls Limited :\u003cbr\u003e\u003ca href=\"https:\/\/www.autonexcontrol.com\/\"\u003ehttps:\/\/www.autonexcontrol.com\/\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45581192593569,"sku":"FS-SDO-0448","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/FS-SDO-0448.jpg?v=1766720587","url":"https:\/\/www.autonexcontrol.com\/az\/products\/honeywell-fs-sdo-0448-48v-dc-safety-output","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}