{"product_id":"ge-fanuc-emerson-ic694mdl645-voltage-input-module","title":"GE Fanuc Emerson IC694MDL645 Voltage Input Module","description":"\u003ch2\u003e\n\u003cstrong\u003eGE Fanuc IC694MDL645 Discrete Input Module\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e24V DC\u003c\/span\u003e standard industrial control power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e0-30V DC\u003c\/span\u003e wide operating voltage span\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e24V DC\u003c\/span\u003e optimal performance level\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e7 mA\u003c\/span\u003e per channel typical consumption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e11.5-30V DC\u003c\/span\u003e recognized input range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Voltage:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e0-5V DC\u003c\/span\u003e guaranteed off condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCurrent and Timing Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Current:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e3.2 mA\u003c\/span\u003e minimum detection level\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Current:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e1.1 mA\u003c\/span\u003e maximum leakage current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e7 ms\u003c\/span\u003e typical signal recognition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption 5V Bus:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e80 mA\u003c\/span\u003e from backplane supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption 24V Bus:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e125 mA\u003c\/span\u003e from field power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIsolation and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-to-Backplane Isolation:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e250V AC\u003c\/span\u003e continuous protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame-to-Ground Isolation:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e1500V AC\u003c\/span\u003e for 1 minute withstand\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Testing:\u003c\/strong\u003e Meets industrial safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Protection:\u003c\/strong\u003e Designed for noisy environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e Robust against electrical interference\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e0°C to 60°C\u003c\/span\u003e standard industrial range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e-40°C to 85°C\u003c\/span\u003e extreme condition handling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e5% to 95%\u003c\/span\u003e non-condensing operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e5 g\u003c\/span\u003e at 10-500 Hz frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e \u003cspan style=\"color: red;\"\u003e15 g\u003c\/span\u003e at 11 ms duration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eWhat variants of the IC694MDL645 are available?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe module comes in Standard, HT (high-temperature), and CC (conformal-coated) versions for different environments.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eWhat isolation protection does it provide?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe module offers \u003cspan style=\"color: red;\"\u003e250V AC\u003c\/span\u003e field-to-backplane and \u003cspan style=\"color: red;\"\u003e1500V AC\u003c\/span\u003e frame-to-ground isolation.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eWhat are the power requirements?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIt consumes \u003cspan style=\"color: red;\"\u003e80 mA at 5V\u003c\/span\u003e from backplane and \u003cspan style=\"color: red;\"\u003e125 mA at 24V\u003c\/span\u003e from field supply.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139252641953,"sku":"IC694MDL645","price":206.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC693CPU3632_E5_89_AF_E6_9C_AC-1.jpg?v=1758191594","url":"https:\/\/www.autonexcontrol.com\/az\/products\/ge-fanuc-emerson-ic694mdl645-voltage-input-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}