{"product_id":"ge-fanuc-analog-input-module-ic200alg630","title":"GE Fanuc Analog Input Module IC200ALG630","description":"\u003ch2\u003eGE Fanuc VersaMax IC200ALG630 Thermocouple \/ mV Input Module\u003c\/h2\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e VersaMax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC200ALG630\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e Thermocouple \/ mV Input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 7 inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Sensors:\u003c\/strong\u003e Thermocouple J, K, T, S, R\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003emV Ranges:\u003c\/strong\u003e ±19.5mV to ±625mV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e \u003cspan style=\"color: #8e44ad;\"\u003e16 bits\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Resolution:\u003c\/strong\u003e 15 bits plus sign\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy at 25°C:\u003c\/strong\u003e ±0.2% voltage, ±0.15% temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e60 ms per channel at 60 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e \u003cspan style=\"color: #27ae60;\"\u003e125 mA at 5V\u003c\/span\u003e, \u003cspan style=\"color: #27ae60;\"\u003e125 mA at 3.3V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250 VAC continuous, 1500 VAC for 1 min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMeasurement Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIC200ALG630\u003c\/strong\u003e achieves \u003cstrong\u003e±0.15% temperature accuracy\u003c\/strong\u003e at standard conditions.\u003c\/li\u003e\n\u003cli\u003eIt maintains excellent voltage measurement accuracy of \u003cstrong\u003e±0.2%\u003c\/strong\u003e for precise signal conversion.\u003c\/li\u003e\n\u003cli\u003eAdvanced \u003cspan style=\"color: #8e44ad;\"\u003e\u003cstrong\u003e16-bit resolution\u003c\/strong\u003e\u003c\/span\u003e captures minute signal variations.\u003c\/li\u003e\n\u003cli\u003eThe module handles multiple millivolt ranges from \u003cstrong\u003e±19.5mV to ±625mV\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eTemperature sensitivity remains below \u003cstrong\u003e±0.004% per degree Celsius\u003c\/strong\u003e for stable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Operation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module installs directly into any VersaMax PLC rack with standard mounting.\u003c\/li\u003e\n\u003cli\u003eLED status indicators show \u003cstrong\u003egreen for normal operation\u003c\/strong\u003e and \u003cstrong\u003eamber for fault conditions\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIt operates within a wide temperature range from \u003cstrong\u003e0°C to 60°C\u003c\/strong\u003e for industrial environments.\u003c\/li\u003e\n\u003cli\u003eThe compact \u003cstrong\u003e4.3 x 2.63 x 1.95 inch\u003c\/strong\u003e design optimizes control panel space.\u003c\/li\u003e\n\u003cli\u003eElectrical isolation of \u003cstrong\u003e250 VAC continuous\u003c\/strong\u003e protects against noise and surges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostics \u0026amp; Safety Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComprehensive diagnostics include \u003cstrong\u003eopen thermocouple detection\u003c\/strong\u003e for maintenance alerts.\u003c\/li\u003e\n\u003cli\u003eThe system monitors for \u003cstrong\u003eover-range and under-range conditions\u003c\/strong\u003e to prevent errors.\u003c\/li\u003e\n\u003cli\u003eThermistor error detection ensures signal integrity and measurement validity.\u003c\/li\u003e\n\u003cli\u003eHigh \u003cstrong\u003e1500 VAC isolation for 1 minute\u003c\/strong\u003e provides exceptional electrical protection.\u003c\/li\u003e\n\u003cli\u003eVisual status indicators offer immediate operational feedback to operators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Shipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEach \u003cstrong\u003eIC200ALG630\u003c\/strong\u003e module comes in original GE Fanuc packaging.\u003c\/li\u003e\n\u003cli\u003eWe maintain stock for immediate shipment from our warehouse.\u003c\/li\u003e\n\u003cli\u003eAll products are \u003cstrong\u003ebrand new and genuine\u003c\/strong\u003e with full manufacturer quality.\u003c\/li\u003e\n\u003cli\u003eWe ship worldwide using reliable carriers including FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eOrders typically process and ship within \u003cstrong\u003e5 business days\u003c\/strong\u003e after confirmation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat thermocouple types does the IC200ALG630 support?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe module supports \u003cstrong\u003eJ, K, T, S, and R type thermocouples\u003c\/strong\u003e. This covers most industrial temperature measurement applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHow many input channels does this module provide?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIC200ALG630\u003c\/strong\u003e offers \u003cstrong\u003eseven independent input channels\u003c\/strong\u003e. You can connect multiple sensors to one compact module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat is the measurement resolution of this module?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIt features high \u003cspan style=\"color: #8e44ad;\"\u003e\u003cstrong\u003e16-bit resolution\u003c\/strong\u003e\u003c\/span\u003e for exceptional measurement precision. This ensures accurate temperature and voltage readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHow fast does the module update its readings?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe update rate is \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e60 ms per channel at 60 Hz\u003c\/strong\u003e\u003c\/span\u003e. This provides timely data for process control and monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat diagnostic features are included?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComprehensive diagnostics include \u003cstrong\u003eopen thermocouple detection, range alarms, and thermistor errors\u003c\/strong\u003e. These features help maintain system reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDo you have the IC200ALG630 in stock?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYes, we maintain stock of the \u003cstrong\u003eIC200ALG630\u003c\/strong\u003e for immediate shipment. All units are brand new and genuine GE Fanuc products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor technical support and pricing information, please contact: \u003cstrong\u003e\u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139249823905,"sku":"IC200ALG630","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC200ALG630.jpg?v=1763964146","url":"https:\/\/www.autonexcontrol.com\/az\/products\/ge-fanuc-analog-input-module-ic200alg630","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}