{"product_id":"allen-bradley-analog-input-module-1756-if16h","title":"Allen-Bradley Analog Input Module 1756-IF16H","description":"\u003ch2\u003eAllen-Bradley 1756-IF16H ControlLogix HART Analog Input Module\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003eAllen-Bradley\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e\u003cstrong\u003e1756-IF16H\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ControlLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e HART Analog Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 16 differential current inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Capability:\u003c\/strong\u003e Dedicated modem per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Types:\u003c\/strong\u003e 0-20mA and 4-20mA signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-21 bits programmable resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Ranges:\u003c\/strong\u003e 0-20mA or 4-20mA selectable per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e Better than 0.13% of range on all filters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConversion Method:\u003c\/strong\u003e Successive approximation ADC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Formats:\u003c\/strong\u003e Integer and IEEE 32-bit floating point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 200mA @ 5.1V DC, 125mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 4.02 Watts total backplane power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHART Communication Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDedicated HART modem on each of the 16 channels\u003c\/li\u003e\n\u003cli\u003eSimultaneous analog signal and HART data acquisition\u003c\/li\u003e\n\u003cli\u003eMultiple data formats: analog only or analog with HART PV\u003c\/li\u003e\n\u003cli\u003eHART scan time of approximately 1 second for all channels\u003c\/li\u003e\n\u003cli\u003eCompatible with all HART-enabled field instruments\u003c\/li\u003e\n\u003cli\u003eConfigurable HART data integration into controller tags\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eScanning \u0026amp; Filtering Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Scan Time:\u003c\/strong\u003e 11-328 ms (filter dependent)\u003c\/li\u003e\n\u003cli\u003eReal-time Sampling (RTS) for synchronized data acquisition\u003c\/li\u003e\n\u003cli\u003eConfigurable digital filters for noise reduction\u003c\/li\u003e\n\u003cli\u003eModule-wide and per-channel filtering options\u003c\/li\u003e\n\u003cli\u003eUnder-range and over-range detection for all channels\u003c\/li\u003e\n\u003cli\u003eWire-off detection for broken wire identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is HART protocol used for?\u003c\/strong\u003e HART allows digital communication with smart field instruments while maintaining analog signal measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat current signals does this module support?\u003c\/strong\u003e The module handles both 0-20mA and 4-20mA current input signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many HART modems does the module have?\u003c\/strong\u003e It features 16 dedicated HART modems, one for each input channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat terminal blocks are compatible?\u003c\/strong\u003e Use 1756-TBCH or 1756-TBS6H removable terminal blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have this module in stock?\u003c\/strong\u003e Yes, we maintain stock for immediate shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the module's accuracy?\u003c\/strong\u003e Better than 0.13% of range across all filter settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I mix different signal types?\u003c\/strong\u003e Yes, each channel can be individually configured for 0-20mA or 4-20mA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor technical specifications and volume pricing:\u003c\/p\u003e\n\u003cp\u003eContact: \u003cu\u003e\u003cstrong\u003esales@nex-auto.com\u003c\/strong\u003e\u003c\/u\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45397089484961,"sku":"1756-IF16H","price":269.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/1756-IF16H.jpg?v=1763630101","url":"https:\/\/www.autonexcontrol.com\/az\/products\/allen-bradley-analog-input-module-1756-if16h","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}