{"product_id":"6es7312-1ae13-0ab0-siemens-simatic-s7-300-cpu-312-compact-plc","title":"6ES7312-1AE13-0AB0 Siemens SIMATIC S7-300 CPU 312 Compact PLC","description":"\u003ch2\u003e\u003cstrong\u003eSiemens SIMATIC S7-300 CPU 312 – 6ES7312-1AE13-0AB0 Spare Part\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Siemens SIMATIC S7-300, \u003cstrong style=\"color: #2c3e66;\"\u003e6ES7312-1AE13-0AB0\u003c\/strong\u003e. Hardware functional status 01 and firmware V2.6 ensure stable performance. This spare part CPU supports the SIMATIC S7-300 platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Specifications:\u003c\/strong\u003e Rated value at 24V DC with a permissible range of 20.4V to 28.8V. Typical power loss is only \u003cspan style=\"color: #2c3e66;\"\u003e2.5 W\u003c\/span\u003e, enhancing energy efficiency. The integrated power supply simplifies panel wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory \u0026amp; Processing:\u003c\/strong\u003e Integrated work memory provides 32 kbyte for user programs. The MMC slot supports cards up to 4 Mbyte for load memory. Data retention on MMC lasts at least 10 years after the last programming.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddressing \u0026amp; Communication:\u003c\/strong\u003e Process image handles 128 byte for inputs and outputs. The integrated MPI interface allows easy connection to programming devices. Cable length for MPI reaches up to 50 m without a repeater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Characteristics:\u003c\/strong\u003e Dimensions measure \u003cspan style=\"color: #2c3e66;\"\u003e130 mm x 40 mm x 125 mm (LxWxH)\u003c\/span\u003e. Weight is approximately \u003cspan style=\"color: #2c3e66;\"\u003e0.27 kg\u003c\/span\u003e, making it suitable for compact control cabinets. The module fits standard S7-300 rail mounting systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Configuration:\u003c\/strong\u003e Supports a single rack with up to 8 modules per rack. Number of DP masters is none, but it can use up to 4 CPs for LAN. Operable FMs and CPs follow recommended limits for stable system design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse a miniature circuit breaker type C with a minimum of 2 A for external power protection. Type B requires at least 4 A for safe operation.\u003c\/li\u003e\n\u003cli\u003ePlace the CPU in the first slot of the rack to maintain proper addressing. Expansion units are not supported for this model.\u003c\/li\u003e\n\u003cli\u003eConnect shielded cables up to 1,000 m for standard signals. For technological functions, limit shielded cables to 100 m.\u003c\/li\u003e\n\u003cli\u003eEnsure unshielded cables do not exceed 600 m for standard digital signals. Follow the cable length guidelines to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eWire digital outputs with a load resistance range of 48 Ω to 4 kΩ. Minimum load current for signal “1” is 5 mA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the \u003cstrong style=\"color: #2c3e66;\"\u003e6ES7312-1AE13-0AB0\u003c\/strong\u003e a new original part?\u003c\/strong\u003e Yes, we supply this unit as a brand new original spare part.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have this CPU in stock?\u003c\/strong\u003e Yes, we maintain stock and ship within 5 business days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich carriers do you use for delivery?\u003c\/strong\u003e We ship using DHL, FedEx, and UPS for reliable global service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your return policy?\u003c\/strong\u003e We support returns within 30 days of delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this CPU without a micro memory card?\u003c\/strong\u003e No, the \u003cstrong\u003e6ES7312-1AE13-0AB0\u003c\/strong\u003e requires a micro memory card for operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich programming package supports this CPU?\u003c\/strong\u003e Use STEP 7 V5.2 SP1 or higher with the corresponding hardware update.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor inquiries, contact us at \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or via WhatsApp at \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e. Partner: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003eNexAuto Technology Limited\u003c\/a\u003e.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":45867790893217,"sku":"6ES7312-1AE13-0AB0","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/6ES7312-1AE13-0AB0.jpg?v=1774858452","url":"https:\/\/www.autonexcontrol.com\/az\/products\/6es7312-1ae13-0ab0-siemens-simatic-s7-300-cpu-312-compact-plc","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}