{"product_id":"1756-it16-analog-input-module-allen-bradley","title":"1756-IT16 Analog Input Module Allen-Bradley","description":"\u003ch2\u003eAllen-Bradley 1756-IT16 ControlLogix Thermocouple\/mV Input Module\u003c\/h2\u003e\n\u003ch3\u003eInput Specifications \u0026amp; Sensor Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Count:\u003c\/strong\u003e 16 non-isolated input channels for multiple sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e -100 to +100 millivolts for precise measurements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple Types:\u003c\/strong\u003e Supports B, C, E, J, K, N, R, S, T sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt Capability:\u003c\/strong\u003e Direct mV input for custom sensor applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Resolution:\u003c\/strong\u003e 24-bit high-resolution analog-to-digital conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearization Standard:\u003c\/strong\u003e ITS-90 type thermocouple linearization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Requirements:\u003c\/strong\u003e 200 mA at 5.1V DC, 80 mA at 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 3 Watts maximum during operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Output:\u003c\/strong\u003e 9.9 BTU per hour heat generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Rating:\u003c\/strong\u003e 250 Volts continuous isolation voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection:\u003c\/strong\u003e +\/- 30 Volts DC input protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Rejection:\u003c\/strong\u003e 75 dB normal mode rejection at 60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation:\u003c\/strong\u003e Requires two external CJC sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy Enhancement:\u003c\/strong\u003e Temperature compensation for stable readings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indication:\u003c\/strong\u003e LED display for module status monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e High noise immunity for reliable operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced I\/O:\u003c\/strong\u003e Advanced control capabilities for precise applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Density:\u003c\/strong\u003e Space-efficient 16-channel design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Type:\u003c\/strong\u003e Open-style for chassis mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method:\u003c\/strong\u003e Direct installation in ControlLogix chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 60°C (32 to 140°F) range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, c-UL-us, RCM, Ex, KC, EAC, IECEx standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Family:\u003c\/strong\u003e ControlLogix 1756 enhanced I\/O series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Focus:\u003c\/strong\u003e Advanced temperature control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRequired Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCJC Sensors:\u003c\/strong\u003e Two 1756-CJC sensors required (sold separately)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Compatibility:\u003c\/strong\u003e All standard ControlLogix chassis models\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Considerations:\u003c\/strong\u003e Proper shielding for noise-sensitive signals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Tools:\u003c\/strong\u003e Standard ControlLogix installation equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Software:\u003c\/strong\u003e Studio 5000 for module setup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Comprehensive installation and user manuals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Channel Density:\u003c\/strong\u003e 16 channels maximize space utilization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Sensor Support:\u003c\/strong\u003e Wide thermocouple type compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Measurement:\u003c\/strong\u003e 24-bit resolution ensures accurate readings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Robustness:\u003c\/strong\u003e Designed for harsh industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Integration:\u003c\/strong\u003e Seamless ControlLogix platform compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Performance:\u003c\/strong\u003e Enhanced stability and accuracy features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eQuality \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Certifications:\u003c\/strong\u003e Meets international safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Manufacturing:\u003c\/strong\u003e Allen-Bradley reliability and durability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Standards:\u003c\/strong\u003e Complies with industrial automation requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Ratings:\u003c\/strong\u003e Comprehensive protection and isolation features\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e Meets global environmental standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerformance Validation:\u003c\/strong\u003e Thorough testing and quality assurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Delivery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Condition:\u003c\/strong\u003e Brand new, factory original equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e In stock for immediate shipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing Time:\u003c\/strong\u003e Orders ship within five business days\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e FedEx, UPS, and DHL available worldwide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Secure manufacturer packaging with protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder Tracking:\u003c\/strong\u003e Provided for all customer shipments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat thermocouple types does this module support?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003e1756-IT16\u003c\/strong\u003e supports B, C, E, J, K, N, R, S, T thermocouple types and mV inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAre the CJC sensors included with the module?\u003c\/strong\u003e\u003cbr\u003eNo, two 1756-CJC cold junction compensation sensors must be purchased separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the resolution of this analog input module?\u003c\/strong\u003e\u003cbr\u003eIt features 24-bit resolution for high-precision temperature measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many channels does this module provide?\u003c\/strong\u003e\u003cbr\u003eIt offers 16 non-isolated input channels in a high-density design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the input voltage range for this module?\u003c\/strong\u003e\u003cbr\u003eThe input range is -100 to +100 millivolts for sensor measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this module suitable for harsh industrial environments?\u003c\/strong\u003e\u003cbr\u003eYes, it carries multiple certifications and is designed for industrial use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your standard shipping time for this product?\u003c\/strong\u003e\u003cbr\u003eWe typically process and ship orders within five business days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor technical specifications or application assistance, contact our measurement specialists at: \u003cu\u003e\u003cstrong\u003esales@nex-auto.com\u003c\/strong\u003e\u003c\/u\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45400785518753,"sku":"1756-IT16","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/1756-IT16-1.jpg?v=1763718899","url":"https:\/\/www.autonexcontrol.com\/az\/products\/1756-it16-analog-input-module-allen-bradley","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}