{"product_id":"3500-61-04-02-bently-nevada-recorder-outputs-monitor","title":"3500\/61-04-02 Bently Nevada | Recorder Outputs Monitor","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 3500\/61-04-02 Temperature Monitor with Recorder Outputs\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview and Suffix Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada (Made in U.S.A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e \u003cstrong\u003e3500\/61-04-02\u003c\/strong\u003e – Temperature Monitors with Recorder Outputs\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Module Type:\u003c\/strong\u003e 04 = TC Isolated I\/O Module with External Terminations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval Option:\u003c\/strong\u003e 02 = ATEX \/ IECEx \/ CSA (Class 1, Zone 2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Suffix Information:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/61-04-02\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-04:\u003c\/strong\u003e Thermocouple (TC) Isolated I\/O Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02:\u003c\/strong\u003e Hazardous area approval (ATEX, IECEx, CSA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Terminations:\u003c\/strong\u003e Yes, for easy field wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e3500\/61-04-02\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal:\u003c\/strong\u003e Accepts 1 to 6 RTD or TC transducer signals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 10 MΩ for each lead input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/60:\u003c\/strong\u003e Nominal 7 watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/61:\u003c\/strong\u003e Nominal 9 watts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple (TC) Ranges:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eType E: -100°C to +1000°C (-148°F to +1832°F)\u003c\/li\u003e\n\u003cli\u003eType J: -18°C to +760°C (0°F to +1400°F)\u003c\/li\u003e\n\u003cli\u003eType K: -18°C to +1370°C (0°F to +2498°F)\u003c\/li\u003e\n\u003cli\u003eType T: -160°C to +400°C (-256°F to +752°F)\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #e03e2d;\"\u003eNote: Type E range reduces above +35°C ambient to -60°C to +1000°C\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Ranges (Platinum 0.00385):\u003c\/strong\u003e -200°C to +850°C (-328°F to +1562°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Ranges (Platinum 0.00392):\u003c\/strong\u003e -200°C to +700°C (-328°F to +1292°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Ranges (Nickel 120Ω):\u003c\/strong\u003e -80°C to +260°C (-112°F to +500°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Ranges (Copper 10Ω):\u003c\/strong\u003e -100°C to +260°C (-148°F to +500°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Isolation (Isolated I\/O Module):\u003c\/strong\u003e 500Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel to Channel Isolation:\u003c\/strong\u003e 250Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecorder Output:\u003c\/strong\u003e +4 to +20 mA proportional to full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Resistance Range:\u003c\/strong\u003e 0 to 600 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Resolution:\u003c\/strong\u003e 0.3662 µA per bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy (Standard Rack, External Termination Isolated):\u003c\/strong\u003e \u003cspan style=\"color: #e03e2d;\"\u003e±1°C at 25°C (±1.8°F at 77°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature (Internal\/External Termination):\u003c\/strong\u003e -30°C to +65°C (-22°F to +150°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C (-40°F to +185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitor Module Dimensions:\u003c\/strong\u003e 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitor Weight:\u003c\/strong\u003e 0.91 kg (2.0 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Module Weight:\u003c\/strong\u003e 0.45 kg (1.0 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Space:\u003c\/strong\u003e 1 full-height front slot (Monitor) + 1 full-height rear slot (I\/O Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have the \u003cstrong\u003e3500\/61-04-02\u003c\/strong\u003e in stock?\u003c\/strong\u003e\u003cbr\u003eYes, we keep this model in stock for immediate orders.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical delivery time?\u003c\/strong\u003e\u003cbr\u003eWe ship within 5 business days after order confirmation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich carriers do you use for shipping?\u003c\/strong\u003e\u003cbr\u003eWe use FedEx, UPS, and DHL for fast and reliable delivery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I return this item?\u003c\/strong\u003e\u003cbr\u003eYes, we support returns within 30 days of receipt.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a short circuit occurs on the recorder output?\u003c\/strong\u003e\u003cbr\u003eThe monitor continues normal operation without damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the accuracy for 10 Ω Copper RTDs?\u003c\/strong\u003e\u003cbr\u003eAccuracy is ±3°C at 25°C with 1°C resolution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFor inquiries, please contact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or \u003ca href=\"https:\/\/wa.me\/8615392496282\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46447031681185,"sku":"3500\/61-04-02","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/3500_61-04-02.jpg?v=1779269836","url":"https:\/\/www.autonexcontrol.com\/ar\/products\/3500-61-04-02-bently-nevada-recorder-outputs-monitor","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}